Effect of Manual and Mechanical Glide Path Preparation on Working Length Accuracy.
Comparison of Working Length Accuracy Following Manual and Mechanical Glide Path Preparation: An In Vitro Study.
연구 개요
상태
상세 설명
This study is an in vitro randomized controlled experimental investigation designed to evaluate and compare the accuracy of working length achievement following manual and mechanical glide path preparation techniques during root canal treatment.
A total of 60 extracted single-rooted permanent teeth with intact roots, mature apices, and minimal canal curvature (≤15°) will be selected according to predefined inclusion and exclusion criteria. After disinfection and sterilization, the teeth will be mounted in resin blocks to ensure stability during instrumentation. The samples will then be randomly allocated into two equal groups (n = 30 each) using a computer-generated randomization method.
Standard access cavities will be prepared for all samples. Canal patency and initial working length will be determined using an electronic apex locator and confirmed with digital periapical radiographs. Silicone stoppers will be used to standardize reference points for all measurements.
In Group 1 (manual glide path group), glide path preparation will be performed using a size #10 stainless steel K-file with a watch-winding and gentle filing motion. In Group 2 (mechanical glide path group), glide path preparation will be carried out using rotary PathFile instruments in sequence with an engine-driven handpiece, following the manufacturer's recommendations. All procedures will be performed by a single operator to eliminate operator-related variability.
After completion of glide path preparation and canal shaping, the final working length will be re-determined using the same apex locator and radiographic methods. The difference between the initial and final working lengths will be measured in millimeters for each specimen and recorded as the primary outcome variable.
Statistical analysis will be performed using SPSS software. Descriptive statistics (mean and standard deviation) will be calculated, and inferential analysis will include paired t-tests for within-group comparisons and independent t-tests for between-group comparisons, with a significance level set at p < 0.05.
The results of this study are expected to provide evidence regarding which glide path preparation technique better preserves working length accuracy, thereby assisting clinicians in selecting optimal endodontic instrumentation protocols and improving treatment outcomes.
연구 유형
등록 (추정된)
단계
- 해당 없음
연락처 및 위치
연구 연락처
- 이름: Alina Malik, BDS
- 전화번호: +923049579435
- 이메일: alinamalik32198@gmail.com
연구 연락처 백업
- 이름: Alina Malik, BDS
- 이메일: alinamalik32198@gmail.com
참여기준
자격 기준
공부할 수 있는 나이
- 어린이
- 성인
- 고령자
건강한 자원 봉사자를 받아들입니다
설명
Inclusion Criteria:
Extracted permanent single-rooted teeth. Teeth with fully formed mature apices. Teeth with intact roots and no structural defects. Root canals with curvature less than 15 degrees. Teeth with patent canals allowing negotiation with a size #10 K-file.
Exclusion Criteria:
Teeth with caries, fractures, cracks, or root defects. Teeth with previous endodontic treatment. Teeth showing root resorption or calcified canals. Teeth with unusual root canal anatomy or multiple canals. Teeth with severe canal curvature greater than 15 degrees. Teeth with immature apices or open apices.
공부 계획
연구는 어떻게 설계됩니까?
디자인 세부사항
- 주 목적: 치료
- 할당: 무작위
- 중재 모델: 병렬 할당
- 마스킹: 하나의
무기와 개입
참가자 그룹 / 팔 |
개입 / 치료 |
|---|---|
|
실험적: Manual Glide Path Preparation
Teeth in this arm will undergo glide path preparation using manual stainless steel K-files (size #10) with a watch-winding motion and gentle vertical filing to establish a smooth glide path up to the predetermined working length.
|
Glide path is created using stainless steel K-files (size #10) with a watch-winding motion and gentle vertical filing to establish a smooth path from the canal orifice to the apex.
|
|
활성 비교기: Mechanical Glide Path Preparation
Teeth in this arm will undergo glide path preparation using rotary PathFile instruments (#13 and #16) with an engine-driven handpiece, following the manufacturer's instructions to establish the glide path up to the predetermined working length.
|
Glide path is created using rotary PathFile instruments (#13 and #16) with an engine-driven handpiece, following manufacturer instructions to establish a smooth path from the canal orifice to the apex.
|
연구는 무엇을 측정합니까?
주요 결과 측정
결과 측정 |
측정값 설명 |
기간 |
|---|---|---|
|
Accuracy of working length achievement in mm
기간: Six months
|
The primary outcome of this study will be the accuracy of working length achievement after glide path preparation using manual and mechanical techniques.
It will be assessed by measuring the difference between the initial working length (recorded before instrumentation) and the final working length (recorded after glide path preparation and canal shaping) in millimeters.
Working length measurements will be obtained using an apex locator and confirmed with digital periapical radiographs.
A smaller difference between the initial and final working lengths will indicate better maintenance and achievement of the accurate working length.
|
Six months
|
공동 작업자 및 조사자
수사관
- 수석 연구원: Aleena Malik, BDS, Pakistan
- 수석 연구원: Alina Malik, School Of Dentistry,Shaheed Zulfiqar Ali Bhutto Medical University,Islamabad
연구 기록 날짜
연구 주요 날짜
연구 시작 (추정된)
기본 완료 (추정된)
연구 완료 (추정된)
연구 등록 날짜
최초 제출
QC 기준을 충족하는 최초 제출
처음 게시됨 (실제)
연구 기록 업데이트
마지막 업데이트 게시됨 (실제)
QC 기준을 충족하는 마지막 업데이트 제출
마지막으로 확인됨
추가 정보
이 연구와 관련된 용어
기타 연구 ID 번호
- SOD/ERB/2025/72
개별 참가자 데이터(IPD) 계획
개별 참가자 데이터(IPD)를 공유할 계획입니까?
약물 및 장치 정보, 연구 문서
미국 FDA 규제 의약품 연구
미국 FDA 규제 기기 제품 연구
이 정보는 변경 없이 clinicaltrials.gov 웹사이트에서 직접 가져온 것입니다. 귀하의 연구 세부 정보를 변경, 제거 또는 업데이트하도록 요청하는 경우 register@clinicaltrials.gov. 문의하십시오. 변경 사항이 clinicaltrials.gov에 구현되는 즉시 저희 웹사이트에도 자동으로 업데이트됩니다. .