AI ECG Algorithm for Detecting LV Systolic Dysfunction
Prospective Observational Cohort Study of Deep Learning-based ECG Algorithm for Detecting Left Ventricular Systolic Dysfunction
연구 개요
상세 설명
Left ventricular systolic dysfunction (LVSD) is associated with an increased risk of heart failure, hospitalization, and mortality. Although transthoracic echocardiography is the standard method for assessing left ventricular ejection fraction (LVEF), its widespread use as a screening tool is limited by availability, cost, and the need for specialized personnel. Artificial intelligence (AI)-based electrocardiography (ECG) algorithms have emerged as promising tools for identifying patients with reduced LVEF using routinely acquired ECG signals.
DeepECG LVSD is a deep learning-based ECG algorithm developed to detect LVSD (LVEF ≤40%) from standard 12-lead ECG recordings. Previous retrospective validation studies demonstrated high diagnostic performance; however, prospective clinical validation in real-world practice remains limited.
The purpose of this prospective observational cohort study is to evaluate the diagnostic performance and clinical utility of DeepECG LVSD in adult patients undergoing both ECG and transthoracic echocardiography at Ajou University Hospital. Approximately 15,000 patients aged 19 years or older who have undergone ECG and echocardiography within 30 days will be enrolled.
The primary objective is to assess the accuracy of the AI algorithm for detecting LVSD using echocardiographic LVEF as the reference standard. Diagnostic performance will be evaluated using the area under the receiver operating characteristic curve (AUROC), sensitivity, specificity, positive predictive value, negative predictive value, and overall accuracy.
Secondary objectives include evaluating the association between AI-predicted LVSD and short-term clinical outcomes, including 30-day all-cause mortality, emergency department visits, and heart failure rehospitalization. Exploratory subgroup analyses will assess algorithm performance according to demographic and clinical characteristics, including age, sex, heart failure status, chronic kidney disease, hypertension, diabetes mellitus, and the interval between ECG and echocardiography.
This study is designed as a minimal-risk observational study and will provide prospective evidence regarding the effectiveness of AI-enabled ECG screening for LVSD in routine clinical practice. Findings from this study may support broader implementation of AI-based ECG tools for the early identification of patients at risk for heart failure and reduced left ventricular systolic function.
연구 유형
등록 (추정된)
연락처 및 위치
연구 연락처
- 이름: MOONSEUNG SOH, MD
- 전화번호: +82-31-219-5111
- 이메일: mssoh7701@gmail.com
연구 장소
-
-
Gyeonggi-do
-
Suwon, Gyeonggi-do, 대한민국, 16499
- 모병
- Ajou University School of Medicine
-
연락하다:
- MOONSEUNG SOH, MD
- 전화번호: +82-31-219-5111
- 이메일: mssoh7701@gmail.com
-
-
참여기준
자격 기준
공부할 수 있는 나이
- 성인
- 고령자
건강한 자원 봉사자를 받아들입니다
샘플링 방법
연구 인구
설명
Inclusion Criteria:
- Adults aged ≥19 years.
- Patients who underwent both transthoracic echocardiography and 12-lead electrocardiography (ECG) at Ajou University Hospital in the outpatient, inpatient, or emergency department setting.
- ECG and echocardiography performed within 30 days of each other.
Exclusion Criteria:
- Interval between ECG and echocardiography greater than 30 days.
- Missing or corrupted original ECG waveform data (XML or HL7 format).
- Presence of an implanted cardiac device, including a permanent pacemaker, implantable cardioverter-defibrillator (ICD), or cardiac resynchronization therapy (CRT) device.
- Missing age, sex, or left ventricular ejection fraction (LVEF) data.
공부 계획
연구는 어떻게 설계됩니까?
디자인 세부사항
코호트 및 개입
그룹/코호트 |
개입 / 치료 |
|---|---|
|
Adults aged ≥19 years with ECG and echocardiography performed within 30 days
Adult patients aged 19 years or older who underwent both transthoracic echocardiography and electrocardiography (ECG) within 30 days of each other
|
There is no intervention group
|
연구는 무엇을 측정합니까?
주요 결과 측정
결과 측정 |
측정값 설명 |
기간 |
|---|---|---|
|
AUROC for detection of LVSD (LVEF ≤40%)
기간: During procedure
|
Diagnostic performance including AUROC, sensitivity, specificity, positive predictive value, negative predictive value, and accuracy.
|
During procedure
|
공동 작업자 및 조사자
간행물 및 유용한 링크
일반 간행물
- Lopez-Jimenez F, Alger HM, Attia ZI, Barry B, Chatterjee R, Dolor R, Friedman PA, Greene SJ, Greenwood J, Gundurao V, Hackett S, Jain P, Kinaszczuk A, Mehta K, O'Grady J, Pandey A, Pullins C, Puranik AR, Ranganathan MK, Rushlow D, Stampehl M, Subramanian V, Vassor K, Zhu X, Awasthi S. A multicenter pragmatic implementation study of AI-ECG-based clinical decision support software to identify low LVEF: Clinical trial design and methods. Am Heart J Plus. 2025 Mar 21;54:100528. doi: 10.1016/j.ahjo.2025.100528. eCollection 2025 Jun.
- Choi J, Lee S, Chang M, Lee Y, Oh GC, Lee HY. Author Correction: Deep learning of ECG waveforms for diagnosis of heart failure with a reduced left ventricular ejection fraction. Sci Rep. 2022 Oct 13;12(1):17191. doi: 10.1038/s41598-022-22012-7. No abstract available.
- Attia ZI, Kapa S, Lopez-Jimenez F, McKie PM, Ladewig DJ, Satam G, Pellikka PA, Enriquez-Sarano M, Noseworthy PA, Munger TM, Asirvatham SJ, Scott CG, Carter RE, Friedman PA. Screening for cardiac contractile dysfunction using an artificial intelligence-enabled electrocardiogram. Nat Med. 2019 Jan;25(1):70-74. doi: 10.1038/s41591-018-0240-2. Epub 2019 Jan 7.
연구 기록 날짜
연구 주요 날짜
연구 시작 (실제)
기본 완료 (추정된)
연구 완료 (추정된)
연구 등록 날짜
최초 제출
QC 기준을 충족하는 최초 제출
처음 게시됨 (실제)
연구 기록 업데이트
마지막 업데이트 게시됨 (실제)
QC 기준을 충족하는 마지막 업데이트 제출
마지막으로 확인됨
추가 정보
이 연구와 관련된 용어
개별 참가자 데이터(IPD) 계획
개별 참가자 데이터(IPD)를 공유할 계획입니까?
IPD 계획 설명
약물 및 장치 정보, 연구 문서
미국 FDA 규제 의약품 연구
미국 FDA 규제 기기 제품 연구
이 정보는 변경 없이 clinicaltrials.gov 웹사이트에서 직접 가져온 것입니다. 귀하의 연구 세부 정보를 변경, 제거 또는 업데이트하도록 요청하는 경우 register@clinicaltrials.gov. 문의하십시오. 변경 사항이 clinicaltrials.gov에 구현되는 즉시 저희 웹사이트에도 자동으로 업데이트됩니다. .