Inter-Rater Reliability of Ultra Sound Based Rectus Abdominis Thickness Following Blood Flow Restriction Training
Inter-Rater Reliability of Ultra Sound Based Rectus Abdominis Thickness Following Blood Flow Restriction Training : A Retrospective Analysis.
연구 개요
상세 설명
A retrospective methodological reliability study design will be employed to evaluate the inter-rater reliability of ultrasound-based measurements of rectus abdominis muscle thickness following a standardized blood flow restriction (BFR) training protocol. The study will utilize previously collected B-mode ultrasound images obtained from healthy young adult male participants who completed the original BFR training protocol. The existing dataset will be reviewed according to predefined eligibility criteria, and only ultrasound images of sufficient quality for identification and measurement of the rectus abdominis muscle will be included in the analysis.
The original BFR training protocol involved low-load resistance exercise performed under blood flow restriction. During the intervention, pneumatic cuffs were applied to the limbs, and participants performed a standardized squat exercise protocol at a low percentage of one-repetition maximum with prescribed repetitions and rest intervals. Ultrasound images of the rectus abdominis obtained according to the standardized imaging protocol will be analyzed retrospectively. The rectus abdominis was selected because it is a superficial abdominal muscle that can be visualized using B-mode ultrasonography and has relatively well-defined anatomical boundaries, allowing its thickness to be assessed using a standardized measurement procedure. Furthermore, the rectus abdominis contributes to trunk stabilization during functional and resistance exercises.
Ultrasound images will be analyzed using ImageJ software. Two independent raters will perform the measurements of rectus abdominis muscle thickness using the same standardized measurement protocol. The raters will independently identify the anatomical boundaries of the rectus abdominis and obtain linear thickness measurements from the ultrasound images. The use of a single standardized image-analysis platform and identical measurement procedures for both raters will minimize variability related to software and measurement techniques. The primary outcome will be the rectus abdominis muscle thickness measured in millimeters (mm).
Inter-rater reliability will be assessed using the Intraclass Correlation Coefficient (ICC) with a two-way random-effects model for absolute agreement and single measurements [ICC (2,1)], reported with the corresponding 95% confidence interval. ICC values below 0.50 will be interpreted as poor reliability, values from 0.50 to 0.75 as moderate reliability, values from 0.75 to 0.90 as good reliability, and values above 0.90 as excellent reliability. Absolute reliability and measurement error will additionally be assessed using the Standard Error of Measurement (SEM) and Minimal Detectable Change at the 95% confidence level (MDC95), where appropriate. Bland-Altman analysis will be performed to evaluate systematic differences and limits of agreement between the two raters. All statistical analyses will be conducted using SPSS, with the level of statistical significance set at p < 0.05.
If the ultrasound-based rectus abdominis thickness measurement demonstrates good to excellent inter-rater reliability, the findings will support the reproducibility of the standardized measurement protocol and its application in future research involving abdominal muscle morphology. The study may provide a methodological foundation for future investigations examining changes in abdominal muscle morphology following BFR and other exercise interventions, with potential relevance to sports physiotherapy, rehabilitation, and exercise science.
연구 유형
등록 (추정된)
연락처 및 위치
연구 연락처
- 이름: Muhammad Haris, DPT
- 전화번호: 03437181808
- 이메일: harismughal5154@gmail.com
연구 연락처 백업
- 이름: Dr Saad Rauf, PhD
- 전화번호: 03325957732
연구 장소
-
-
-
Islamabad, 파키스탄, 44000
- 모병
- Faculty of Rehabilitation for Data Collection and Research Work
-
연락하다:
- Muhammad Haris
- 전화번호: 03437181808
-
-
참여기준
자격 기준
공부할 수 있는 나이
- 성인
건강한 자원 봉사자를 받아들입니다
샘플링 방법
연구 인구
설명
Inclusion Criteria:
- Recreationally Active
Exclusion Criteria:
- Known Musculoskeletal injury
공부 계획
연구는 어떻게 설계됩니까?
디자인 세부사항
코호트 및 개입
그룹/코호트 |
|---|
|
Retrospective BFR Cohort
Healthy active male participants who underwent a short-duration blood flow restriction (BFR) training protocol.
Pre- and post-training ultrasound images of the rectus abdominis muscle were retrospectively analyzed to assess inter-rater reliability of ultrasound-based muscle thickness measurements.
|
|
Group 1
Healthy active male participants assessed before the BFR training program.
Baseline B-mode ultrasound images of the rectus abdominis muscle were obtained and used for measurement of muscle thickness.
|
연구는 무엇을 측정합니까?
주요 결과 측정
결과 측정 |
측정값 설명 |
기간 |
|---|---|---|
|
Inter-rater reliability of ultrasound-based rectus abdominis muscle thickness measurement
기간: Baseline (pre-training) and post-training ultrasound images obtained at the completion of the two-week BFR training protocol.
|
Inter-rater reliability between two independent raters in measuring rectus abdominis muscle thickness from B-mode ultrasound images using ImageJ software.
|
Baseline (pre-training) and post-training ultrasound images obtained at the completion of the two-week BFR training protocol.
|
2차 결과 측정
결과 측정 |
측정값 설명 |
기간 |
|---|---|---|
|
Inter-rater reliability of ultrasound-based rectus abdominis muscle thickness measurement
기간: Pre-training and immediately post-training.
|
Rectus abdominis muscle thickness
|
Pre-training and immediately post-training.
|
공동 작업자 및 조사자
수사관
- 수석 연구원: Saad Rauf, PhD, Riphah International University, Isra University, Islamabad
연구 기록 날짜
연구 주요 날짜
연구 시작 (실제)
기본 완료 (추정된)
연구 완료 (추정된)
연구 등록 날짜
최초 제출
QC 기준을 충족하는 최초 제출
처음 게시됨 (실제)
연구 기록 업데이트
마지막 업데이트 게시됨 (실제)
QC 기준을 충족하는 마지막 업데이트 제출
마지막으로 확인됨
추가 정보
이 연구와 관련된 용어
기타 연구 ID 번호
- REC/MS-PT/02569
개별 참가자 데이터(IPD) 계획
개별 참가자 데이터(IPD)를 공유할 계획입니까?
약물 및 장치 정보, 연구 문서
미국 FDA 규제 의약품 연구
미국 FDA 규제 기기 제품 연구
이 정보는 변경 없이 clinicaltrials.gov 웹사이트에서 직접 가져온 것입니다. 귀하의 연구 세부 정보를 변경, 제거 또는 업데이트하도록 요청하는 경우 register@clinicaltrials.gov. 문의하십시오. 변경 사항이 clinicaltrials.gov에 구현되는 즉시 저희 웹사이트에도 자동으로 업데이트됩니다. .