Inter-Rater Reliability of Ultra Sound Based Rectus Abdominis Thickness Following Blood Flow Restriction Training

2026년 8월 5일 업데이트: Riphah International University

Inter-Rater Reliability of Ultra Sound Based Rectus Abdominis Thickness Following Blood Flow Restriction Training : A Retrospective Analysis.

Accurate assessment of skeletal muscle morphology is important in sports physiotherapy, exercise rehabilitation, and research. B-mode ultrasonography is a non-invasive and accessible method for assessing muscle thickness; however, ultrasound-based measurements may be influenced by image acquisition, anatomical landmark identification, and operator-dependent measurement procedures. Establishing inter-rater reliability is therefore essential to determine whether different assessors can obtain consistent measurements of muscle thickness from the same ultrasound images. The rectus abdominis is an important component of the abdominal musculature and contributes to trunk stabilization and functional performance during exercise. Blood flow restriction (BFR) training has gained increasing attention as a low-load exercise strategy for promoting muscular adaptations, although research has predominantly focused on peripheral limb muscles. Therefore, this study aims to evaluate the inter-rater reliability of ultrasound-based rectus abdominis muscle thickness measurements following a standardized BFR training protocol using ImageJ software. Establishing reliable measurement of rectus abdominis thickness will provide a methodological basis for future research investigating abdominal muscle morphology and adaptations in sports physiotherapy, exercise rehabilitation, and BFR-based training.

연구 개요

상태

모병

상세 설명

A retrospective methodological reliability study design will be employed to evaluate the inter-rater reliability of ultrasound-based measurements of rectus abdominis muscle thickness following a standardized blood flow restriction (BFR) training protocol. The study will utilize previously collected B-mode ultrasound images obtained from healthy young adult male participants who completed the original BFR training protocol. The existing dataset will be reviewed according to predefined eligibility criteria, and only ultrasound images of sufficient quality for identification and measurement of the rectus abdominis muscle will be included in the analysis.

The original BFR training protocol involved low-load resistance exercise performed under blood flow restriction. During the intervention, pneumatic cuffs were applied to the limbs, and participants performed a standardized squat exercise protocol at a low percentage of one-repetition maximum with prescribed repetitions and rest intervals. Ultrasound images of the rectus abdominis obtained according to the standardized imaging protocol will be analyzed retrospectively. The rectus abdominis was selected because it is a superficial abdominal muscle that can be visualized using B-mode ultrasonography and has relatively well-defined anatomical boundaries, allowing its thickness to be assessed using a standardized measurement procedure. Furthermore, the rectus abdominis contributes to trunk stabilization during functional and resistance exercises.

Ultrasound images will be analyzed using ImageJ software. Two independent raters will perform the measurements of rectus abdominis muscle thickness using the same standardized measurement protocol. The raters will independently identify the anatomical boundaries of the rectus abdominis and obtain linear thickness measurements from the ultrasound images. The use of a single standardized image-analysis platform and identical measurement procedures for both raters will minimize variability related to software and measurement techniques. The primary outcome will be the rectus abdominis muscle thickness measured in millimeters (mm).

Inter-rater reliability will be assessed using the Intraclass Correlation Coefficient (ICC) with a two-way random-effects model for absolute agreement and single measurements [ICC (2,1)], reported with the corresponding 95% confidence interval. ICC values below 0.50 will be interpreted as poor reliability, values from 0.50 to 0.75 as moderate reliability, values from 0.75 to 0.90 as good reliability, and values above 0.90 as excellent reliability. Absolute reliability and measurement error will additionally be assessed using the Standard Error of Measurement (SEM) and Minimal Detectable Change at the 95% confidence level (MDC95), where appropriate. Bland-Altman analysis will be performed to evaluate systematic differences and limits of agreement between the two raters. All statistical analyses will be conducted using SPSS, with the level of statistical significance set at p < 0.05.

If the ultrasound-based rectus abdominis thickness measurement demonstrates good to excellent inter-rater reliability, the findings will support the reproducibility of the standardized measurement protocol and its application in future research involving abdominal muscle morphology. The study may provide a methodological foundation for future investigations examining changes in abdominal muscle morphology following BFR and other exercise interventions, with potential relevance to sports physiotherapy, rehabilitation, and exercise science.

연구 유형

관찰

등록 (추정된)

50

연락처 및 위치

이 섹션에서는 연구를 수행하는 사람들의 연락처 정보와 이 연구가 수행되는 장소에 대한 정보를 제공합니다.

연구 연락처

연구 연락처 백업

  • 이름: Dr Saad Rauf, PhD
  • 전화번호: 03325957732

연구 장소

      • Islamabad, 파키스탄, 44000
        • 모병
        • Faculty of Rehabilitation for Data Collection and Research Work
        • 연락하다:
          • Muhammad Haris
          • 전화번호: 03437181808

참여기준

연구원은 적격성 기준이라는 특정 설명에 맞는 사람을 찾습니다. 이러한 기준의 몇 가지 예는 개인의 일반적인 건강 상태 또는 이전 치료입니다.

자격 기준

공부할 수 있는 나이

  • 성인

건강한 자원 봉사자를 받아들입니다

아니

샘플링 방법

비확률 샘플

연구 인구

Non Athletes

설명

Inclusion Criteria:

  • Recreationally Active

Exclusion Criteria:

  • Known Musculoskeletal injury

공부 계획

이 섹션에서는 연구 설계 방법과 연구가 측정하는 내용을 포함하여 연구 계획에 대한 세부 정보를 제공합니다.

연구는 어떻게 설계됩니까?

디자인 세부사항

코호트 및 개입

그룹/코호트
Retrospective BFR Cohort
Healthy active male participants who underwent a short-duration blood flow restriction (BFR) training protocol. Pre- and post-training ultrasound images of the rectus abdominis muscle were retrospectively analyzed to assess inter-rater reliability of ultrasound-based muscle thickness measurements.
Group 1
Healthy active male participants assessed before the BFR training program. Baseline B-mode ultrasound images of the rectus abdominis muscle were obtained and used for measurement of muscle thickness.

연구는 무엇을 측정합니까?

주요 결과 측정

결과 측정
측정값 설명
기간
Inter-rater reliability of ultrasound-based rectus abdominis muscle thickness measurement
기간: Baseline (pre-training) and post-training ultrasound images obtained at the completion of the two-week BFR training protocol.
Inter-rater reliability between two independent raters in measuring rectus abdominis muscle thickness from B-mode ultrasound images using ImageJ software.
Baseline (pre-training) and post-training ultrasound images obtained at the completion of the two-week BFR training protocol.

2차 결과 측정

결과 측정
측정값 설명
기간
Inter-rater reliability of ultrasound-based rectus abdominis muscle thickness measurement
기간: Pre-training and immediately post-training.
Rectus abdominis muscle thickness
Pre-training and immediately post-training.

공동 작업자 및 조사자

여기에서 이 연구와 관련된 사람과 조직을 찾을 수 있습니다.

수사관

  • 수석 연구원: Saad Rauf, PhD, Riphah International University, Isra University, Islamabad

연구 기록 날짜

이 날짜는 ClinicalTrials.gov에 대한 연구 기록 및 요약 결과 제출의 진행 상황을 추적합니다. 연구 기록 및 보고된 결과는 공개 웹사이트에 게시되기 전에 특정 품질 관리 기준을 충족하는지 확인하기 위해 국립 의학 도서관(NLM)에서 검토합니다.

연구 주요 날짜

연구 시작 (실제)

2026년 8월 4일

기본 완료 (추정된)

2026년 9월 6일

연구 완료 (추정된)

2026년 9월 20일

연구 등록 날짜

최초 제출

2026년 8월 5일

QC 기준을 충족하는 최초 제출

2026년 8월 5일

처음 게시됨 (실제)

2026년 8월 10일

연구 기록 업데이트

마지막 업데이트 게시됨 (실제)

2026년 8월 10일

QC 기준을 충족하는 마지막 업데이트 제출

2026년 8월 5일

마지막으로 확인됨

2026년 8월 1일

추가 정보

이 연구와 관련된 용어

기타 연구 ID 번호

  • REC/MS-PT/02569

개별 참가자 데이터(IPD) 계획

개별 참가자 데이터(IPD)를 공유할 계획입니까?

아니요

약물 및 장치 정보, 연구 문서

미국 FDA 규제 의약품 연구

아니

미국 FDA 규제 기기 제품 연구

아니