此页面是自动翻译的,不保证翻译的准确性。请参阅 英文版 对于源文本。

Inter-Rater Reliability of Ultra Sound Based Rectus Abdominis Thickness Following Blood Flow Restriction Training

2026年8月5日 更新者:Riphah International University

Inter-Rater Reliability of Ultra Sound Based Rectus Abdominis Thickness Following Blood Flow Restriction Training : A Retrospective Analysis.

Accurate assessment of skeletal muscle morphology is important in sports physiotherapy, exercise rehabilitation, and research. B-mode ultrasonography is a non-invasive and accessible method for assessing muscle thickness; however, ultrasound-based measurements may be influenced by image acquisition, anatomical landmark identification, and operator-dependent measurement procedures. Establishing inter-rater reliability is therefore essential to determine whether different assessors can obtain consistent measurements of muscle thickness from the same ultrasound images. The rectus abdominis is an important component of the abdominal musculature and contributes to trunk stabilization and functional performance during exercise. Blood flow restriction (BFR) training has gained increasing attention as a low-load exercise strategy for promoting muscular adaptations, although research has predominantly focused on peripheral limb muscles. Therefore, this study aims to evaluate the inter-rater reliability of ultrasound-based rectus abdominis muscle thickness measurements following a standardized BFR training protocol using ImageJ software. Establishing reliable measurement of rectus abdominis thickness will provide a methodological basis for future research investigating abdominal muscle morphology and adaptations in sports physiotherapy, exercise rehabilitation, and BFR-based training.

研究概览

地位

招聘中

详细说明

A retrospective methodological reliability study design will be employed to evaluate the inter-rater reliability of ultrasound-based measurements of rectus abdominis muscle thickness following a standardized blood flow restriction (BFR) training protocol. The study will utilize previously collected B-mode ultrasound images obtained from healthy young adult male participants who completed the original BFR training protocol. The existing dataset will be reviewed according to predefined eligibility criteria, and only ultrasound images of sufficient quality for identification and measurement of the rectus abdominis muscle will be included in the analysis.

The original BFR training protocol involved low-load resistance exercise performed under blood flow restriction. During the intervention, pneumatic cuffs were applied to the limbs, and participants performed a standardized squat exercise protocol at a low percentage of one-repetition maximum with prescribed repetitions and rest intervals. Ultrasound images of the rectus abdominis obtained according to the standardized imaging protocol will be analyzed retrospectively. The rectus abdominis was selected because it is a superficial abdominal muscle that can be visualized using B-mode ultrasonography and has relatively well-defined anatomical boundaries, allowing its thickness to be assessed using a standardized measurement procedure. Furthermore, the rectus abdominis contributes to trunk stabilization during functional and resistance exercises.

Ultrasound images will be analyzed using ImageJ software. Two independent raters will perform the measurements of rectus abdominis muscle thickness using the same standardized measurement protocol. The raters will independently identify the anatomical boundaries of the rectus abdominis and obtain linear thickness measurements from the ultrasound images. The use of a single standardized image-analysis platform and identical measurement procedures for both raters will minimize variability related to software and measurement techniques. The primary outcome will be the rectus abdominis muscle thickness measured in millimeters (mm).

Inter-rater reliability will be assessed using the Intraclass Correlation Coefficient (ICC) with a two-way random-effects model for absolute agreement and single measurements [ICC (2,1)], reported with the corresponding 95% confidence interval. ICC values below 0.50 will be interpreted as poor reliability, values from 0.50 to 0.75 as moderate reliability, values from 0.75 to 0.90 as good reliability, and values above 0.90 as excellent reliability. Absolute reliability and measurement error will additionally be assessed using the Standard Error of Measurement (SEM) and Minimal Detectable Change at the 95% confidence level (MDC95), where appropriate. Bland-Altman analysis will be performed to evaluate systematic differences and limits of agreement between the two raters. All statistical analyses will be conducted using SPSS, with the level of statistical significance set at p < 0.05.

If the ultrasound-based rectus abdominis thickness measurement demonstrates good to excellent inter-rater reliability, the findings will support the reproducibility of the standardized measurement protocol and its application in future research involving abdominal muscle morphology. The study may provide a methodological foundation for future investigations examining changes in abdominal muscle morphology following BFR and other exercise interventions, with potential relevance to sports physiotherapy, rehabilitation, and exercise science.

研究类型

观察性的

注册 (估计的)

50

联系人和位置

本节提供了进行研究的人员的详细联系信息,以及有关进行该研究的地点的信息。

学习联系方式

研究联系人备份

  • 姓名:Dr Saad Rauf, PhD
  • 电话号码:03325957732

学习地点

      • Islamabad、巴基斯坦、44000
        • 招聘中
        • Faculty of Rehabilitation for Data Collection and Research Work
        • 接触:
          • Muhammad Haris
          • 电话号码:03437181808

参与标准

研究人员寻找符合特定描述的人,称为资格标准。这些标准的一些例子是一个人的一般健康状况或先前的治疗。

资格标准

适合学习的年龄

  • 成人

接受健康志愿者

取样方法

非概率样本

研究人群

Non Athletes

描述

Inclusion Criteria:

  • Recreationally Active

Exclusion Criteria:

  • Known Musculoskeletal injury

学习计划

本节提供研究计划的详细信息,包括研究的设计方式和研究的衡量标准。

研究是如何设计的?

设计细节

队列和干预

团体/队列
Retrospective BFR Cohort
Healthy active male participants who underwent a short-duration blood flow restriction (BFR) training protocol. Pre- and post-training ultrasound images of the rectus abdominis muscle were retrospectively analyzed to assess inter-rater reliability of ultrasound-based muscle thickness measurements.
Group 1
Healthy active male participants assessed before the BFR training program. Baseline B-mode ultrasound images of the rectus abdominis muscle were obtained and used for measurement of muscle thickness.

研究衡量的是什么?

主要结果指标

结果测量
措施说明
大体时间
Inter-rater reliability of ultrasound-based rectus abdominis muscle thickness measurement
大体时间:Baseline (pre-training) and post-training ultrasound images obtained at the completion of the two-week BFR training protocol.
Inter-rater reliability between two independent raters in measuring rectus abdominis muscle thickness from B-mode ultrasound images using ImageJ software.
Baseline (pre-training) and post-training ultrasound images obtained at the completion of the two-week BFR training protocol.

次要结果测量

结果测量
措施说明
大体时间
Inter-rater reliability of ultrasound-based rectus abdominis muscle thickness measurement
大体时间:Pre-training and immediately post-training.
Rectus abdominis muscle thickness
Pre-training and immediately post-training.

合作者和调查者

在这里您可以找到参与这项研究的人员和组织。

调查人员

  • 首席研究员:Saad Rauf, PhD、Riphah International University, Isra University, Islamabad

研究记录日期

这些日期跟踪向 ClinicalTrials.gov 提交研究记录和摘要结果的进度。研究记录和报告的结果由国家医学图书馆 (NLM) 审查,以确保它们在发布到公共网站之前符合特定的质量控制标准。

研究主要日期

学习开始 (实际的)

2026年8月4日

初级完成 (估计的)

2026年9月6日

研究完成 (估计的)

2026年9月20日

研究注册日期

首次提交

2026年8月5日

首先提交符合 QC 标准的

2026年8月5日

首次发布 (实际的)

2026年8月10日

研究记录更新

最后更新发布 (实际的)

2026年8月10日

上次提交的符合 QC 标准的更新

2026年8月5日

最后验证

2026年8月1日

更多信息

与本研究相关的术语

其他研究编号

  • REC/MS-PT/02569

计划个人参与者数据 (IPD)

计划共享个人参与者数据 (IPD)?

药物和器械信息、研究文件

研究美国 FDA 监管的药品

研究美国 FDA 监管的设备产品

此信息直接从 clinicaltrials.gov 网站检索,没有任何更改。如果您有任何更改、删除或更新研究详细信息的请求,请联系 register@clinicaltrials.gov. clinicaltrials.gov 上实施更改,我们的网站上也会自动更新.

订阅