Segmented Indirect Versus Direct Bracket Bonding

2026년 9월 30일 업데이트: Omar Alkadhi, Riyadh Elm University

Bond Failure of a Segmented Modified Indirect Bonding Technique Versus Direct Bonding: A Randomized Clinical Trial

This randomized clinical trial compared two methods of attaching orthodontic brackets to teeth: conventional direct bonding, in which each bracket is placed and bonded individually in the mouth, and a segmented modified indirect bonding technique, in which brackets are first positioned on a plaster model of the patient's teeth and then transferred to the mouth in segments using a hot-glue transfer tray. The purpose was to find out whether the two techniques differ in how often brackets come loose (bond failure) during treatment.

Eighteen patients receiving fixed orthodontic appliances at Riyadh Elm University, Riyadh, Saudi Arabia, were randomly assigned so that their brackets were placed by either the direct or the modified indirect technique. The same bracket type and adhesive were used in both groups. Patients were examined every four weeks for six months, and any bracket that debonded was recorded along with the tooth involved, the arch (upper or lower), the side (right or left), and the time from bonding to failure. The main outcome was the time from bonding to bracket failure; the investigators also compared failure rates and examined whether failure varied by tooth type, arch, or side.

연구 개요

상세 설명

Background and rationale: Direct bonding, in which orthodontic brackets are positioned and light-cured individually on each tooth, remains the most common technique but depends heavily on operator visibility and isolation at the moment of placement, which is constrained on posterior teeth. Indirect bonding positions brackets on a working cast under direct vision and transfers them to the dentition in a tray, and has been proposed to improve placement and reduce chairside time. Whether indirect bonding reduces clinical bond failure compared with direct bonding is not established, and clinical failure data for low-cost analogue (hot-glue) transfer-tray methods are limited.

Objective: To compare time to bracket bond failure (primary outcome) and bond-failure rate (secondary outcome) between conventional direct bonding and a segmented modified indirect bonding technique, and to examine whether failure varied by tooth type, arch, or side.

Design: Prospective, parallel-arm, single-center randomized clinical trial. Participants were allocated by simple randomization from a computer-generated sequence to direct bonding or segmented modified indirect bonding. The trial was open-label, as the bonding technique could not be masked from the operator.

Setting: Orthodontic clinics, Riyadh Elm University, Riyadh, Saudi Arabia. Participants: Patients seeking fixed-appliance orthodontic treatment were screened against eligibility criteria. Patients with overbite greater than 3 mm; with crowns, bridges, veneers, restorations, or enamel hypoplasia on the teeth to be bonded; with severely rotated or blocked-out teeth; or with partially erupted teeth were excluded. Eighteen participants were enrolled after written informed consent.

Interventions: In the direct group, teeth were pumiced, etched with 37% phosphoric acid (Meta Etchant, Meta Biomed), rinsed thoroughly, and excess water was removed; Ortho Solo Universal Sealant and Bond Enhancer (Ormco) was applied, and brackets were bonded with Enlight light-cured adhesive (Ormco), then light-cured for 20 seconds occlusally and 20 seconds gingivally. In the modified indirect group, alginate impressions were poured in dental stone; brackets were fixed to the casts in planned positions; segmented transfer trays (separate segments for molars, premolar-canine, and lateral/central incisors per quadrant) were fabricated with thermal (hot) glue covering the occlusal and partial lingual surfaces, leaving the bracket exposed below the slot. Teeth were pumiced, etched with the same 37% phosphoric acid, rinsed thoroughly, and excess water was removed; Ortho Solo Universal Sealant and Bond Enhancer was applied to the etched teeth and Enlight adhesive to the bracket bases before tray insertion; the trays were then seated and light-cured for 20 seconds before removal. The same bracket type and adhesive system were used in both arms.

Outcomes: The primary outcome was time to bracket bond failure (days from bonding to first debonding); the secondary outcome was the bond-failure rate. Each event was recorded with the tooth, arch (maxilla/mandible), side (right/left), date, and time from bonding to failure in days. The unit of analysis was the individual bracket. Participants were reviewed every four weeks for six months; debonded brackets were re-bonded directly.

Analysis: Time to failure was analysed with Kaplan-Meier estimates, the log-rank test and Cox proportional-hazards regression. Failure rates were compared with chi-square and exact tests and Firth penalized logistic regression, with an exploratory Holm-corrected analysis of technique by tooth type and side.

연구 유형

중재적

등록 (실제)

18

단계

  • 해당 없음

연락처 및 위치

이 섹션에서는 연구를 수행하는 사람들의 연락처 정보와 이 연구가 수행되는 장소에 대한 정보를 제공합니다.

연구 장소

    • Riyadh Region
      • Riyadh, Riyadh Region, 사우디 아라비아, 12734
        • Riyadh Elm university

참여기준

연구원은 적격성 기준이라는 특정 설명에 맞는 사람을 찾습니다. 이러한 기준의 몇 가지 예는 개인의 일반적인 건강 상태 또는 이전 치료입니다.

자격 기준

공부할 수 있는 나이

  • 어린이
  • 성인
  • 고령자

건강한 자원 봉사자를 받아들입니다

예

연구 대상 성별

모두

설명

Inclusion Criteria:

  • Patients seeking fixed-appliance orthodontic treatment
  • Permanent dentition
  • Teeth to be bonded free of crowns, bridges, veneers, restorations, or enamel hypoplasia

Exclusion Criteria:

  • Overbite greater than 3 mm
  • Teeth with crowns, bridges, veneers, restorations, or enamel hypoplasia
  • Severely rotated or blocked-out teeth
  • Partially erupted teeth

공부 계획

이 섹션에서는 연구 설계 방법과 연구가 측정하는 내용을 포함하여 연구 계획에 대한 세부 정보를 제공합니다.

연구는 어떻게 설계됩니까?

디자인 세부사항

  • 주 목적: 치료
  • 할당: 무작위
  • 중재 모델: 병렬 할당
  • 마스킹: 없음(오픈 라벨)

무기와 개입

참가자 그룹 / 팔
개입 / 치료
활성 비교기: Direct bonding

Orthodontic brackets were bonded directly onto each tooth in the mouth. Teeth were pumiced, etched with 37% phosphoric acid (Meta Etchant, Meta Biomed), rinsed thoroughly, and excess water was removed. Ortho Solo Universal Sealant and Bond Enhancer (Ormco) was applied to the teeth, and each bracket was seated with Enlight light-cured adhesive (Ormco) along the tooth's long axis, vertical height, and mesiodistal midline, then light-cured for 20 seconds occlusally and 20 seconds gingivally. This arm comprised 160 brackets.

Orthodontic brackets bonded individually onto each tooth intraorally. Teeth were pumiced, etched with 37% phosphoric acid (Meta Etchant, Meta Biomed), rinsed thoroughly, and excess water was removed; Ortho Solo Universal Sealant and Bond Enhancer (Ormco) was applied to the teeth, and each bracket was seated with Enlight light-cured adhesive (Ormco) along the tooth's long axis, vertical height, and mesiodistal midline, then light-cured for 20 seconds occlusally and 20 seconds gingivally. The same bracket type and adhesive system were used as in the experimental arm.

실험적: Segmented modified indirect bonding

Orthodontic brackets were first positioned on a dental stone cast in their planned locations, then transferred to the teeth using segmented hot-glue transfer trays (separate segments for molars, premolar-canine, and lateral and central incisors in each quadrant). Teeth were pumiced, etched with 37% phosphoric acid (Meta Etchant, Meta Biomed), rinsed thoroughly, and excess water was removed. Ortho Solo Universal Sealant and Bond Enhancer (Ormco) was applied to the etched teeth and Enlight light-cured adhesive (Ormco) to the bracket bases; the tray was then seated, light-cured for 20 seconds, and removed. This arm comprised 224 brackets.

Orthodontic brackets positioned on a dental stone cast in their planned locations and transferred to the teeth using segmented hot-glue (thermal-glue) transfer trays, fabricated separately for molar, premolar-canine, and lateral and central incisor segments in each quadrant. Teeth were pumiced, etched with 37% phosphoric acid (Meta Etchant, Meta Biomed), rinsed thoroughly, and excess water was removed; Ortho Solo Universal Sealant and Bond Enhancer (Ormco) was applied to the etched teeth and Enlight light-cured adhesive (Ormco) to the bracket bases before tray insertion; the tray was then seated, light-cured for 20 seconds, and removed. The same bracket type and adhesive system were used as in the comparator arm.

연구는 무엇을 측정합니까?

주요 결과 측정

결과 측정
측정값 설명
기간
Time to bracket bond failure (time to debond)
기간: 6 months from bonding

For each bonded bracket, the number of days from bracket placement (bonding) to the first bond failure (debonding). A bracket still bonded at the end of follow-up is right-censored at the date of its last assessment. Only the first failure per bracket is the event; debonded brackets that were re-bonded are not re-entered.

6 months from bonding

2차 결과 측정

결과 측정
측정값 설명
기간
Time to failure among debonded brackets
기간: 6 months from bonding

For brackets that debonded, the time interval from initial bonding to the recorded failure, measured in days.

6 months from bonding
Bracket bond failure rate
기간: 6 months from bonding

Proportion of bonded brackets that debonded (bond failure) during the follow-up period. Each tooth was examined at four-weekly recall visits; a bracket was recorded as failed if it had detached from the tooth. Failure was assessed at the individual-bracket level and expressed as the percentage of brackets that debonded in each group.

6 months from bonding
Bracket bond failure by tooth type, arch, and side
기간: 6 months from bonding

Bracket bond-failure rate compared across tooth type (incisor, canine, premolar, molar), arch (maxilla, mandible), and side (right, left), to assess whether failure varied by bracket location.

6 months from bonding

공동 작업자 및 조사자

여기에서 이 연구와 관련된 사람과 조직을 찾을 수 있습니다.

수사관

  • 연구 책임자: Omar H Alkadhi, Orthodontist, Riyadh Elm University

간행물 및 유용한 링크

연구에 대한 정보 입력을 담당하는 사람이 자발적으로 이러한 간행물을 제공합니다. 이것은 연구와 관련된 모든 것에 관한 것일 수 있습니다.

연구 기록 날짜

이 날짜는 ClinicalTrials.gov에 대한 연구 기록 및 요약 결과 제출의 진행 상황을 추적합니다. 연구 기록 및 보고된 결과는 공개 웹사이트에 게시되기 전에 특정 품질 관리 기준을 충족하는지 확인하기 위해 국립 의학 도서관(NLM)에서 검토합니다.

연구 주요 날짜

연구 시작 (실제)

2020년 11월 22일

기본 완료 (실제)

2021년 10월 19일

연구 완료 (실제)

2021년 10월 19일

연구 등록 날짜

최초 제출

2026년 5월 31일

QC 기준을 충족하는 최초 제출

2026년 9월 30일

처음 게시됨 (실제)

2026년 10월 6일

연구 기록 업데이트

마지막 업데이트 게시됨 (실제)

2026년 10월 6일

QC 기준을 충족하는 마지막 업데이트 제출

2026년 9월 30일

마지막으로 확인됨

2026년 9월 1일

추가 정보

이 연구와 관련된 용어

개별 참가자 데이터(IPD) 계획

개별 참가자 데이터(IPD)를 공유할 계획입니까?

아니요

약물 및 장치 정보, 연구 문서

미국 FDA 규제 의약품 연구

아니

미국 FDA 규제 기기 제품 연구

아니

이 정보는 변경 없이 clinicaltrials.gov 웹사이트에서 직접 가져온 것입니다. 귀하의 연구 세부 정보를 변경, 제거 또는 업데이트하도록 요청하는 경우 register@clinicaltrials.gov. 문의하십시오. 변경 사항이 clinicaltrials.gov에 구현되는 즉시 저희 웹사이트에도 자동으로 업데이트됩니다. .

구독하다