此页面是自动翻译的,不保证翻译的准确性。请参阅 英文版 对于源文本。

Segmented Indirect Versus Direct Bracket Bonding

2026年9月30日 更新者:Omar Alkadhi、Riyadh Elm University

Bond Failure of a Segmented Modified Indirect Bonding Technique Versus Direct Bonding: A Randomized Clinical Trial

This randomized clinical trial compared two methods of attaching orthodontic brackets to teeth: conventional direct bonding, in which each bracket is placed and bonded individually in the mouth, and a segmented modified indirect bonding technique, in which brackets are first positioned on a plaster model of the patient's teeth and then transferred to the mouth in segments using a hot-glue transfer tray. The purpose was to find out whether the two techniques differ in how often brackets come loose (bond failure) during treatment.

Eighteen patients receiving fixed orthodontic appliances at Riyadh Elm University, Riyadh, Saudi Arabia, were randomly assigned so that their brackets were placed by either the direct or the modified indirect technique. The same bracket type and adhesive were used in both groups. Patients were examined every four weeks for six months, and any bracket that debonded was recorded along with the tooth involved, the arch (upper or lower), the side (right or left), and the time from bonding to failure. The main outcome was the time from bonding to bracket failure; the investigators also compared failure rates and examined whether failure varied by tooth type, arch, or side.

研究概览

详细说明

Background and rationale: Direct bonding, in which orthodontic brackets are positioned and light-cured individually on each tooth, remains the most common technique but depends heavily on operator visibility and isolation at the moment of placement, which is constrained on posterior teeth. Indirect bonding positions brackets on a working cast under direct vision and transfers them to the dentition in a tray, and has been proposed to improve placement and reduce chairside time. Whether indirect bonding reduces clinical bond failure compared with direct bonding is not established, and clinical failure data for low-cost analogue (hot-glue) transfer-tray methods are limited.

Objective: To compare time to bracket bond failure (primary outcome) and bond-failure rate (secondary outcome) between conventional direct bonding and a segmented modified indirect bonding technique, and to examine whether failure varied by tooth type, arch, or side.

Design: Prospective, parallel-arm, single-center randomized clinical trial. Participants were allocated by simple randomization from a computer-generated sequence to direct bonding or segmented modified indirect bonding. The trial was open-label, as the bonding technique could not be masked from the operator.

Setting: Orthodontic clinics, Riyadh Elm University, Riyadh, Saudi Arabia. Participants: Patients seeking fixed-appliance orthodontic treatment were screened against eligibility criteria. Patients with overbite greater than 3 mm; with crowns, bridges, veneers, restorations, or enamel hypoplasia on the teeth to be bonded; with severely rotated or blocked-out teeth; or with partially erupted teeth were excluded. Eighteen participants were enrolled after written informed consent.

Interventions: In the direct group, teeth were pumiced, etched with 37% phosphoric acid (Meta Etchant, Meta Biomed), rinsed thoroughly, and excess water was removed; Ortho Solo Universal Sealant and Bond Enhancer (Ormco) was applied, and brackets were bonded with Enlight light-cured adhesive (Ormco), then light-cured for 20 seconds occlusally and 20 seconds gingivally. In the modified indirect group, alginate impressions were poured in dental stone; brackets were fixed to the casts in planned positions; segmented transfer trays (separate segments for molars, premolar-canine, and lateral/central incisors per quadrant) were fabricated with thermal (hot) glue covering the occlusal and partial lingual surfaces, leaving the bracket exposed below the slot. Teeth were pumiced, etched with the same 37% phosphoric acid, rinsed thoroughly, and excess water was removed; Ortho Solo Universal Sealant and Bond Enhancer was applied to the etched teeth and Enlight adhesive to the bracket bases before tray insertion; the trays were then seated and light-cured for 20 seconds before removal. The same bracket type and adhesive system were used in both arms.

Outcomes: The primary outcome was time to bracket bond failure (days from bonding to first debonding); the secondary outcome was the bond-failure rate. Each event was recorded with the tooth, arch (maxilla/mandible), side (right/left), date, and time from bonding to failure in days. The unit of analysis was the individual bracket. Participants were reviewed every four weeks for six months; debonded brackets were re-bonded directly.

Analysis: Time to failure was analysed with Kaplan-Meier estimates, the log-rank test and Cox proportional-hazards regression. Failure rates were compared with chi-square and exact tests and Firth penalized logistic regression, with an exploratory Holm-corrected analysis of technique by tooth type and side.

研究类型

介入性

注册 (实际的)

18

阶段

  • 不适用

联系人和位置

本节提供了进行研究的人员的详细联系信息,以及有关进行该研究的地点的信息。

学习地点

    • Riyadh Region
      • Riyadh、Riyadh Region、沙特阿拉伯、12734
        • Riyadh Elm university

参与标准

研究人员寻找符合特定描述的人,称为资格标准。这些标准的一些例子是一个人的一般健康状况或先前的治疗。

资格标准

适合学习的年龄

  • 孩子
  • 成人
  • 年长者

接受健康志愿者

是的

有资格学习的性别

全部

描述

Inclusion Criteria:

  • Patients seeking fixed-appliance orthodontic treatment
  • Permanent dentition
  • Teeth to be bonded free of crowns, bridges, veneers, restorations, or enamel hypoplasia

Exclusion Criteria:

  • Overbite greater than 3 mm
  • Teeth with crowns, bridges, veneers, restorations, or enamel hypoplasia
  • Severely rotated or blocked-out teeth
  • Partially erupted teeth

学习计划

本节提供研究计划的详细信息,包括研究的设计方式和研究的衡量标准。

研究是如何设计的?

设计细节

  • 主要用途:治疗
  • 分配:随机化
  • 介入模型:并行分配
  • 屏蔽:无(打开标签)

武器和干预

参与者组/臂
干预/治疗
有源比较器:Direct bonding

Orthodontic brackets were bonded directly onto each tooth in the mouth. Teeth were pumiced, etched with 37% phosphoric acid (Meta Etchant, Meta Biomed), rinsed thoroughly, and excess water was removed. Ortho Solo Universal Sealant and Bond Enhancer (Ormco) was applied to the teeth, and each bracket was seated with Enlight light-cured adhesive (Ormco) along the tooth's long axis, vertical height, and mesiodistal midline, then light-cured for 20 seconds occlusally and 20 seconds gingivally. This arm comprised 160 brackets.

Orthodontic brackets bonded individually onto each tooth intraorally. Teeth were pumiced, etched with 37% phosphoric acid (Meta Etchant, Meta Biomed), rinsed thoroughly, and excess water was removed; Ortho Solo Universal Sealant and Bond Enhancer (Ormco) was applied to the teeth, and each bracket was seated with Enlight light-cured adhesive (Ormco) along the tooth's long axis, vertical height, and mesiodistal midline, then light-cured for 20 seconds occlusally and 20 seconds gingivally. The same bracket type and adhesive system were used as in the experimental arm.

实验性的:Segmented modified indirect bonding

Orthodontic brackets were first positioned on a dental stone cast in their planned locations, then transferred to the teeth using segmented hot-glue transfer trays (separate segments for molars, premolar-canine, and lateral and central incisors in each quadrant). Teeth were pumiced, etched with 37% phosphoric acid (Meta Etchant, Meta Biomed), rinsed thoroughly, and excess water was removed. Ortho Solo Universal Sealant and Bond Enhancer (Ormco) was applied to the etched teeth and Enlight light-cured adhesive (Ormco) to the bracket bases; the tray was then seated, light-cured for 20 seconds, and removed. This arm comprised 224 brackets.

Orthodontic brackets positioned on a dental stone cast in their planned locations and transferred to the teeth using segmented hot-glue (thermal-glue) transfer trays, fabricated separately for molar, premolar-canine, and lateral and central incisor segments in each quadrant. Teeth were pumiced, etched with 37% phosphoric acid (Meta Etchant, Meta Biomed), rinsed thoroughly, and excess water was removed; Ortho Solo Universal Sealant and Bond Enhancer (Ormco) was applied to the etched teeth and Enlight light-cured adhesive (Ormco) to the bracket bases before tray insertion; the tray was then seated, light-cured for 20 seconds, and removed. The same bracket type and adhesive system were used as in the comparator arm.

研究衡量的是什么?

主要结果指标

结果测量
措施说明
大体时间
Time to bracket bond failure (time to debond)
大体时间:6 months from bonding

For each bonded bracket, the number of days from bracket placement (bonding) to the first bond failure (debonding). A bracket still bonded at the end of follow-up is right-censored at the date of its last assessment. Only the first failure per bracket is the event; debonded brackets that were re-bonded are not re-entered.

6 months from bonding

次要结果测量

结果测量
措施说明
大体时间
Time to failure among debonded brackets
大体时间:6 months from bonding

For brackets that debonded, the time interval from initial bonding to the recorded failure, measured in days.

6 months from bonding
Bracket bond failure rate
大体时间:6 months from bonding

Proportion of bonded brackets that debonded (bond failure) during the follow-up period. Each tooth was examined at four-weekly recall visits; a bracket was recorded as failed if it had detached from the tooth. Failure was assessed at the individual-bracket level and expressed as the percentage of brackets that debonded in each group.

6 months from bonding
Bracket bond failure by tooth type, arch, and side
大体时间:6 months from bonding

Bracket bond-failure rate compared across tooth type (incisor, canine, premolar, molar), arch (maxilla, mandible), and side (right, left), to assess whether failure varied by bracket location.

6 months from bonding

合作者和调查者

在这里您可以找到参与这项研究的人员和组织。

调查人员

  • 研究主任:Omar H Alkadhi, Orthodontist、Riyadh Elm University

出版物和有用的链接

负责输入研究信息的人员自愿提供这些出版物。这些可能与研究有关。

研究记录日期

这些日期跟踪向 ClinicalTrials.gov 提交研究记录和摘要结果的进度。研究记录和报告的结果由国家医学图书馆 (NLM) 审查,以确保它们在发布到公共网站之前符合特定的质量控制标准。

研究主要日期

学习开始 (实际的)

2020年11月22日

初级完成 (实际的)

2021年10月19日

研究完成 (实际的)

2021年10月19日

研究注册日期

首次提交

2026年5月31日

首先提交符合 QC 标准的

2026年9月30日

首次发布 (实际的)

2026年10月6日

研究记录更新

最后更新发布 (实际的)

2026年10月6日

上次提交的符合 QC 标准的更新

2026年9月30日

最后验证

2026年9月1日

更多信息

与本研究相关的术语

计划个人参与者数据 (IPD)

计划共享个人参与者数据 (IPD)?

不

药物和器械信息、研究文件

研究美国 FDA 监管的药品

不

研究美国 FDA 监管的设备产品

不

此信息直接从 clinicaltrials.gov 网站检索,没有任何更改。如果您有任何更改、删除或更新研究详细信息的请求,请联系 register@clinicaltrials.gov. clinicaltrials.gov 上实施更改,我们的网站上也会自动更新.

订阅