Segmented Indirect Versus Direct Bracket Bonding

30 de setembro de 2026 atualizado por: Omar Alkadhi, Riyadh Elm University

Bond Failure of a Segmented Modified Indirect Bonding Technique Versus Direct Bonding: A Randomized Clinical Trial

This randomized clinical trial compared two methods of attaching orthodontic brackets to teeth: conventional direct bonding, in which each bracket is placed and bonded individually in the mouth, and a segmented modified indirect bonding technique, in which brackets are first positioned on a plaster model of the patient's teeth and then transferred to the mouth in segments using a hot-glue transfer tray. The purpose was to find out whether the two techniques differ in how often brackets come loose (bond failure) during treatment.

Eighteen patients receiving fixed orthodontic appliances at Riyadh Elm University, Riyadh, Saudi Arabia, were randomly assigned so that their brackets were placed by either the direct or the modified indirect technique. The same bracket type and adhesive were used in both groups. Patients were examined every four weeks for six months, and any bracket that debonded was recorded along with the tooth involved, the arch (upper or lower), the side (right or left), and the time from bonding to failure. The main outcome was the time from bonding to bracket failure; the investigators also compared failure rates and examined whether failure varied by tooth type, arch, or side.

Visão geral do estudo

Descrição detalhada

Background and rationale: Direct bonding, in which orthodontic brackets are positioned and light-cured individually on each tooth, remains the most common technique but depends heavily on operator visibility and isolation at the moment of placement, which is constrained on posterior teeth. Indirect bonding positions brackets on a working cast under direct vision and transfers them to the dentition in a tray, and has been proposed to improve placement and reduce chairside time. Whether indirect bonding reduces clinical bond failure compared with direct bonding is not established, and clinical failure data for low-cost analogue (hot-glue) transfer-tray methods are limited.

Objective: To compare time to bracket bond failure (primary outcome) and bond-failure rate (secondary outcome) between conventional direct bonding and a segmented modified indirect bonding technique, and to examine whether failure varied by tooth type, arch, or side.

Design: Prospective, parallel-arm, single-center randomized clinical trial. Participants were allocated by simple randomization from a computer-generated sequence to direct bonding or segmented modified indirect bonding. The trial was open-label, as the bonding technique could not be masked from the operator.

Setting: Orthodontic clinics, Riyadh Elm University, Riyadh, Saudi Arabia. Participants: Patients seeking fixed-appliance orthodontic treatment were screened against eligibility criteria. Patients with overbite greater than 3 mm; with crowns, bridges, veneers, restorations, or enamel hypoplasia on the teeth to be bonded; with severely rotated or blocked-out teeth; or with partially erupted teeth were excluded. Eighteen participants were enrolled after written informed consent.

Interventions: In the direct group, teeth were pumiced, etched with 37% phosphoric acid (Meta Etchant, Meta Biomed), rinsed thoroughly, and excess water was removed; Ortho Solo Universal Sealant and Bond Enhancer (Ormco) was applied, and brackets were bonded with Enlight light-cured adhesive (Ormco), then light-cured for 20 seconds occlusally and 20 seconds gingivally. In the modified indirect group, alginate impressions were poured in dental stone; brackets were fixed to the casts in planned positions; segmented transfer trays (separate segments for molars, premolar-canine, and lateral/central incisors per quadrant) were fabricated with thermal (hot) glue covering the occlusal and partial lingual surfaces, leaving the bracket exposed below the slot. Teeth were pumiced, etched with the same 37% phosphoric acid, rinsed thoroughly, and excess water was removed; Ortho Solo Universal Sealant and Bond Enhancer was applied to the etched teeth and Enlight adhesive to the bracket bases before tray insertion; the trays were then seated and light-cured for 20 seconds before removal. The same bracket type and adhesive system were used in both arms.

Outcomes: The primary outcome was time to bracket bond failure (days from bonding to first debonding); the secondary outcome was the bond-failure rate. Each event was recorded with the tooth, arch (maxilla/mandible), side (right/left), date, and time from bonding to failure in days. The unit of analysis was the individual bracket. Participants were reviewed every four weeks for six months; debonded brackets were re-bonded directly.

Analysis: Time to failure was analysed with Kaplan-Meier estimates, the log-rank test and Cox proportional-hazards regression. Failure rates were compared with chi-square and exact tests and Firth penalized logistic regression, with an exploratory Holm-corrected analysis of technique by tooth type and side.

Tipo de estudo

Intervencional

Inscrição (Real)

18

Estágio

  • Não aplicável

Contactos e Locais

Esta seção fornece os detalhes de contato para aqueles que conduzem o estudo e informações sobre onde este estudo está sendo realizado.

Locais de estudo

    • Riyadh Region
      • Riyadh, Riyadh Region, Arábia Saudita, 12734
        • Riyadh Elm university

Critérios de participação

Os pesquisadores procuram pessoas que se encaixem em uma determinada descrição, chamada de critérios de elegibilidade. Alguns exemplos desses critérios são a condição geral de saúde de uma pessoa ou tratamentos anteriores.

Critérios de elegibilidade

Idades elegíveis para estudo

  • Filho
  • Adulto
  • Adulto mais velho

Aceita Voluntários Saudáveis

Sim

Gêneros Elegíveis para o Estudo

Tudo

Descrição

Inclusion Criteria:

  • Patients seeking fixed-appliance orthodontic treatment
  • Permanent dentition
  • Teeth to be bonded free of crowns, bridges, veneers, restorations, or enamel hypoplasia

Exclusion Criteria:

  • Overbite greater than 3 mm
  • Teeth with crowns, bridges, veneers, restorations, or enamel hypoplasia
  • Severely rotated or blocked-out teeth
  • Partially erupted teeth

Plano de estudo

Esta seção fornece detalhes do plano de estudo, incluindo como o estudo é projetado e o que o estudo está medindo.

Como o estudo é projetado?

Detalhes do projeto

  • Finalidade Principal: Tratamento
  • Alocação: Randomizado
  • Modelo Intervencional: Atribuição Paralela
  • Mascaramento: Nenhum (rótulo aberto)

Armas e Intervenções

Grupo de Participantes / Braço
Intervenção / Tratamento
Comparador Ativo: Direct bonding

Orthodontic brackets were bonded directly onto each tooth in the mouth. Teeth were pumiced, etched with 37% phosphoric acid (Meta Etchant, Meta Biomed), rinsed thoroughly, and excess water was removed. Ortho Solo Universal Sealant and Bond Enhancer (Ormco) was applied to the teeth, and each bracket was seated with Enlight light-cured adhesive (Ormco) along the tooth's long axis, vertical height, and mesiodistal midline, then light-cured for 20 seconds occlusally and 20 seconds gingivally. This arm comprised 160 brackets.

Orthodontic brackets bonded individually onto each tooth intraorally. Teeth were pumiced, etched with 37% phosphoric acid (Meta Etchant, Meta Biomed), rinsed thoroughly, and excess water was removed; Ortho Solo Universal Sealant and Bond Enhancer (Ormco) was applied to the teeth, and each bracket was seated with Enlight light-cured adhesive (Ormco) along the tooth's long axis, vertical height, and mesiodistal midline, then light-cured for 20 seconds occlusally and 20 seconds gingivally. The same bracket type and adhesive system were used as in the experimental arm.

Experimental: Segmented modified indirect bonding

Orthodontic brackets were first positioned on a dental stone cast in their planned locations, then transferred to the teeth using segmented hot-glue transfer trays (separate segments for molars, premolar-canine, and lateral and central incisors in each quadrant). Teeth were pumiced, etched with 37% phosphoric acid (Meta Etchant, Meta Biomed), rinsed thoroughly, and excess water was removed. Ortho Solo Universal Sealant and Bond Enhancer (Ormco) was applied to the etched teeth and Enlight light-cured adhesive (Ormco) to the bracket bases; the tray was then seated, light-cured for 20 seconds, and removed. This arm comprised 224 brackets.

Orthodontic brackets positioned on a dental stone cast in their planned locations and transferred to the teeth using segmented hot-glue (thermal-glue) transfer trays, fabricated separately for molar, premolar-canine, and lateral and central incisor segments in each quadrant. Teeth were pumiced, etched with 37% phosphoric acid (Meta Etchant, Meta Biomed), rinsed thoroughly, and excess water was removed; Ortho Solo Universal Sealant and Bond Enhancer (Ormco) was applied to the etched teeth and Enlight light-cured adhesive (Ormco) to the bracket bases before tray insertion; the tray was then seated, light-cured for 20 seconds, and removed. The same bracket type and adhesive system were used as in the comparator arm.

O que o estudo está medindo?

Medidas de resultados primários

Medida de resultado
Descrição da medida
Prazo
Time to bracket bond failure (time to debond)
Prazo: 6 months from bonding

For each bonded bracket, the number of days from bracket placement (bonding) to the first bond failure (debonding). A bracket still bonded at the end of follow-up is right-censored at the date of its last assessment. Only the first failure per bracket is the event; debonded brackets that were re-bonded are not re-entered.

6 months from bonding

Medidas de resultados secundários

Medida de resultado
Descrição da medida
Prazo
Time to failure among debonded brackets
Prazo: 6 months from bonding

For brackets that debonded, the time interval from initial bonding to the recorded failure, measured in days.

6 months from bonding
Bracket bond failure rate
Prazo: 6 months from bonding

Proportion of bonded brackets that debonded (bond failure) during the follow-up period. Each tooth was examined at four-weekly recall visits; a bracket was recorded as failed if it had detached from the tooth. Failure was assessed at the individual-bracket level and expressed as the percentage of brackets that debonded in each group.

6 months from bonding
Bracket bond failure by tooth type, arch, and side
Prazo: 6 months from bonding

Bracket bond-failure rate compared across tooth type (incisor, canine, premolar, molar), arch (maxilla, mandible), and side (right, left), to assess whether failure varied by bracket location.

6 months from bonding

Colaboradores e Investigadores

É aqui que você encontrará pessoas e organizações envolvidas com este estudo.

Patrocinador

Investigadores

  • Diretor de estudo: Omar H Alkadhi, Orthodontist, Riyadh Elm University

Publicações e links úteis

A pessoa responsável por inserir informações sobre o estudo fornece voluntariamente essas publicações. Estes podem ser sobre qualquer coisa relacionada ao estudo.

Datas de registro do estudo

Essas datas acompanham o progresso do registro do estudo e os envios de resumo dos resultados para ClinicalTrials.gov. Os registros do estudo e os resultados relatados são revisados ​​pela National Library of Medicine (NLM) para garantir que atendam aos padrões específicos de controle de qualidade antes de serem publicados no site público.

Datas Principais do Estudo

Início do estudo (Real)

22 de novembro de 2020

Conclusão Primária (Real)

19 de outubro de 2021

Conclusão do estudo (Real)

19 de outubro de 2021

Datas de inscrição no estudo

Enviado pela primeira vez

31 de maio de 2026

Enviado pela primeira vez que atendeu aos critérios de CQ

30 de setembro de 2026

Primeira postagem (Real)

6 de outubro de 2026

Atualizações de registro de estudo

Última Atualização Postada (Real)

6 de outubro de 2026

Última atualização enviada que atendeu aos critérios de controle de qualidade

30 de setembro de 2026

Última verificação

1 de setembro de 2026

Mais Informações

Termos relacionados a este estudo

Plano para dados de participantes individuais (IPD)

Planeja compartilhar dados de participantes individuais (IPD)?

NÃO

Informações sobre medicamentos e dispositivos, documentos de estudo

Estuda um medicamento regulamentado pela FDA dos EUA

Não

Estuda um produto de dispositivo regulamentado pela FDA dos EUA

Não

Essas informações foram obtidas diretamente do site clinicaltrials.gov sem nenhuma alteração. Se você tiver alguma solicitação para alterar, remover ou atualizar os detalhes do seu estudo, entre em contato com register@clinicaltrials.gov. Assim que uma alteração for implementada em clinicaltrials.gov, ela também será atualizada automaticamente em nosso site .