- ICH GCP
- 미국 임상 시험 레지스트리
- 임상시험 NCT07948057
Validation of Buccolingual Ridge Width Measurements on CBCT Using Direct Intraoperative Measurements
Validation of Buccolingual Ridge Width Measurements on CBCT Using Direct Intraoperative Measurements in The Posterior Mandible During Implant Placement.
This study aims to validate the accuracy of cone beam computed tomography (CBCT) in assessing buccolingual ridge width at posterior mandibular implant sites by comparing CBCT-derived measurements with standardized direct intraoperative caliper measurements obtained at the planned implant position.
연구 개요
상태
상세 설명
The alveolar ridge is a dynamic anatomical structure that undergoes continuous remodeling throughout life in response to functional and biological changes. Following tooth extraction, progressive dimensional alterations occur in the alveolar bone, resulting in reduction of ridge height and width. Several studies have demonstrated that post-extraction bone resorption predominantly affecting the buccolingual dimension, leading to changes in ridge morphology and contour(1, 2). These dimensional changes may complicate accurate radiographic and clinical assessment of the residual alveolar ridge(3).
The success of implant therapy is influenced by several endogenous and exogenous factors. Endogenous factors include the quality and quantity of the supporting alveolar bone, whereas exogenous factors include implant length, diameter, design, and surgical technique. Bone quality varies considerably among different regions of jaws. In general, the mandible demonstrates denser cortical bone than the maxilla, while posterior regions of both jaws tend to exhibit reduced cortical thickness and increased trabecular porosity(4). Therefore, accurate assessment of alveolar bone dimensions is considered a fundamental prerequisite for proper implant planning and successful treatment outcomes(5).
The posterior mandibular region exhibits considerable anatomical variability in alveolar ridge morphology and cortical bone configuration. Buccolingual ridge width in this region may be influenced by residual ridge resorption, cortical plate thickness, and individual anatomical characteristics. In addition, the lingual aspect of the posterior mandible may present anatomical concavities that increase the complexity of ridge assessment and necessitate accurate evaluation of bone dimensions prior to the surgical procedures(6).
Accurate evaluation of buccolingual ridge dimensions is essential for reliable assessment of alveolar bone morphology. Inaccurate estimation of ridge width may result in discrepancies between radiographic findings and actual bone dimensions. Therefore, precise and reproducible measurement methods are required to ensure reliable assessment of alveolar ridge width, particularly in posterior mandibular regions where anatomical variations including lingual concavities and undercut are frequently encountered(5).
Conventional two-dimensional radiographic techniques, including panoramic and periapical radiography, have been widely used for assessment of alveolar bone. However, these imaging modalities have several limitations related to magnification, distortion, superimposition, and inability to evaluate the buccolingual dimension of the alveolar ridge. Such limitations may reduce the accuracy of linear measurements and compromise reliable assessment of bone morphology in posterior mandibular regions(7).
The inherent limitations of conventional two-dimensional imaging techniques have increased the demand for volumetric imaging modalities capable of providing accurate three-dimensional visualization of alveolar bone morphology. Three-dimensional imaging modality eliminates the superimposition and geometric distortion commonly associated with conventional radiography and enables precise multiplanar reconstruction of osseous structures in the axial, coronal, and sagittal planes(8).This capability enables more accurate assessment of the buccolingual dimension of the alveolar ridge and improves radiographic evaluation of anatomical structures in posterior mandibular regions. Consequently, volumetric imaging modalities have become increasingly important for accurate evaluation of alveolar bone dimensions and morphology(9).
Cone-beam computed tomography (CBCT) has become widely utilized in dentomaxillofacial imaging because of its ability to provide high-resolution three-dimensional images with relatively low radiation exposure compared with conventional computed tomography. CBCT enables accurate linear measurements of alveolar bone dimensions and facilitates detailed evaluation of anatomical structures relevant to implant site assessment and surgical planning(9).
Although CBCT has demonstrated high accuracy in assessment of alveolar bone dimensions, validation of CBCT-derived measurements under clinical conditions remains essential. Minor discrepancies between radiographic measurements and actual bone dimensions may still occur due to factors related to image acquisition, voxel size, observer variability, and image interpretation(10). Therefore, direct intraoperative measurements continue to be considered an important reference standard for evaluation of the accuracy and reproducibility of CBCT linear measurements(11).
Direct intraoperative measurements provide accurate assessment of alveolar bone dimensions and are considered the reference standard for validating radiographic measurements in clinical studies. The variations in measurement techniques, anatomical reference points, and imaging protocols may influence the reported accuracy of CBCT measurements. Consequently, further validation studies remain necessary to assess the reliability of CBCT measurements in anatomically variable posterior mandibular regions(12).
Although previous validation studies have reported favorable agreement between CBCT-derived measurements and direct intraoperative measurements in posterior mandibular implant sites, these studies have not employed standardized localization devices to ensure identical measurement points between the radiographic and surgical phases(12, 13). The absence of a standardized point localization method may introduce positional variability in reported measurements, potentially affecting the reliability of comparison outcomes(13). Ridge mapping by CBCT needs to be compared to what would seem to be the most accurate measurement, which is direct caliper measurement following surgical exposure of the bone(11, 14). Therefore, a validated measurement protocol incorporating a standardized stent-based localization device is required to ensure reproducible and accurate comparison between CBCT-derived and intraoperative ridge width measurements.
To the best of our knowledge, there are insufficient clinical studies that have compared CBCT-derived buccolingual ridge width measurements with direct intraoperative caliper measurements obtained at standardized levels corresponding to planned implant positions in posterior mandibular sites. Therefore, the aim of the present study is to validate the accuracy and reliability of buccolingual ridge width measurements obtained from cone-beam computed tomography (CBCT) by comparing them with direct intraoperative caliper measurements in posterior mandibular implant sites using a standardized stent-based localization protocol.
The null hypothesis of the present study is that there will be no statistically significant difference between buccolingual ridge width measurements obtained from CBCT and those obtained through direct intraoperative measurements at posterior mandibular implant sites.
연구 유형
등록 (추정된)
연락처 및 위치
연구 연락처
- 이름: Nayra Mohammed zaki, master degree=
- 전화번호: +201205233092
- 이메일: PG_198213@dent.tanta.edu.eg
참여기준
자격 기준
공부할 수 있는 나이
건강한 자원 봉사자를 받아들입니다
연구 대상 성별
샘플링 방법
연구 인구
Adults aged 18 years or older who are scheduled for single-tooth dental implant placement in the posterior mandible at a previously extracted mandibular first or second molar site. Participants must have sufficient post-extraction healing, identifiable buccolingual ridge morphology, and adequate residual alveolar bone dimensions for implant placement. Patients must be in good general health, have a stable periodontal condition without active inflammation, and meet all inclusion criteria while excluding those with conditions or factors that may interfere with implant surgery or bone healing.
설명
Inclusion Criteria:
- Site in Patients aged 18 years or above.
- Patients indicated for posterior mandibular implant placement at the site of a previously extracted mandibular first or second molar.
- Sufficient post-extraction healing time with preservation of identifiable buccolingual ridge morphology including lingual ridge contour.
- Adequate residual alveolar bone dimensions to permit implant placement.
- Patients in good general health with no systemic conditions contraindicated for implant surgery.
- Patients with stable periodontal condition and no signs of active inflammation.
Exclusion Criteria:
- History of malignancy or head and neck radiation therapy.
- Uncontrolled systemic diseases contraindicated for surgical procedures.
- Active periodontal infection or acute inflammation at the planned implant site.
- History of periodontal or bone augmentation surgery at the planned site.
- Parafunctional occlusal habits including bruxism or clenching.
- Pregnant or lactating females.
- Patients with smoking habits that may affect bone healing.
- Insufficient residual alveolar bone dimensions precluding implant placement without augmentation procedures.
공부 계획
연구는 어떻게 설계됩니까?
디자인 세부사항
- 관찰 모델: OTHER
- 시간 관점: PROSPECTIVE
연구는 무엇을 측정합니까?
주요 결과 측정
결과 측정 |
측정값 설명 |
기간 |
|---|---|---|
|
Difference between CBCT-derived and direct intraoperative buccolingual ridge width
기간: At the time of implant placement surgery (before implant placement
|
Mean difference, absolute difference, and agreement between buccolingual alveolar ridge width measured on CBCT cross-sectional images and direct intraoperative caliper measurements at the standardized stent-based planned implant position. Measurements will be recorded in millimeters (mm). |
At the time of implant placement surgery (before implant placement
|
2차 결과 측정
결과 측정 |
측정값 설명 |
기간 |
|---|---|---|
|
Interobserver and intraobserver reliability of CBCT buccolingual ridge-width measurements
기간: At CBCT image analysis, before implant placement surgery
|
reproducibility of CBCT-derived buccolingual alveolar ridge-width measurements, assessed as intraobserver and interobserver agreement between repeated measurements by two independent calibrated examiners. Measurements will be recorded in millimeters (mm)." |
At CBCT image analysis, before implant placement surgery
|
공동 작업자 및 조사자
스폰서
수사관
- 수석 연구원: Dr. Malak Youssef Mohammed, professor, Faculty of Dentistry, Tanta University, Egypt
연구 기록 날짜
연구 주요 날짜
연구 시작 (추정된)
기본 완료 (추정된)
연구 완료 (추정된)
연구 등록 날짜
최초 제출
QC 기준을 충족하는 최초 제출
처음 게시됨 (실제)
연구 기록 업데이트
마지막 업데이트 게시됨 (실제)
QC 기준을 충족하는 마지막 업데이트 제출
마지막으로 확인됨
추가 정보
이 연구와 관련된 용어
기타 연구 ID 번호
- Validation of CBCT measurement
개별 참가자 데이터(IPD) 계획
개별 참가자 데이터(IPD)를 공유할 계획입니까?
약물 및 장치 정보, 연구 문서
미국 FDA 규제 의약품 연구
미국 FDA 규제 기기 제품 연구
이 정보는 변경 없이 clinicaltrials.gov 웹사이트에서 직접 가져온 것입니다. 귀하의 연구 세부 정보를 변경, 제거 또는 업데이트하도록 요청하는 경우 register@clinicaltrials.gov. 문의하십시오. 변경 사항이 clinicaltrials.gov에 구현되는 즉시 저희 웹사이트에도 자동으로 업데이트됩니다. .