Denna sida har översatts automatiskt och översättningens korrekthet kan inte garanteras. Vänligen se engelsk version för en källtext.

Validation of Buccolingual Ridge Width Measurements on CBCT Using Direct Intraoperative Measurements

13 november 2026 uppdaterad av: Nayra Mohammed Ahmed Zaki, Tanta University

Validation of Buccolingual Ridge Width Measurements on CBCT Using Direct Intraoperative Measurements in The Posterior Mandible During Implant Placement.

This study aims to validate the accuracy of cone beam computed tomography (CBCT) in assessing buccolingual ridge width at posterior mandibular implant sites by comparing CBCT-derived measurements with standardized direct intraoperative caliper measurements obtained at the planned implant position.

Studieöversikt

Detaljerad beskrivning

The alveolar ridge is a dynamic anatomical structure that undergoes continuous remodeling throughout life in response to functional and biological changes. Following tooth extraction, progressive dimensional alterations occur in the alveolar bone, resulting in reduction of ridge height and width. Several studies have demonstrated that post-extraction bone resorption predominantly affecting the buccolingual dimension, leading to changes in ridge morphology and contour(1, 2). These dimensional changes may complicate accurate radiographic and clinical assessment of the residual alveolar ridge(3).

The success of implant therapy is influenced by several endogenous and exogenous factors. Endogenous factors include the quality and quantity of the supporting alveolar bone, whereas exogenous factors include implant length, diameter, design, and surgical technique. Bone quality varies considerably among different regions of jaws. In general, the mandible demonstrates denser cortical bone than the maxilla, while posterior regions of both jaws tend to exhibit reduced cortical thickness and increased trabecular porosity(4). Therefore, accurate assessment of alveolar bone dimensions is considered a fundamental prerequisite for proper implant planning and successful treatment outcomes(5).

The posterior mandibular region exhibits considerable anatomical variability in alveolar ridge morphology and cortical bone configuration. Buccolingual ridge width in this region may be influenced by residual ridge resorption, cortical plate thickness, and individual anatomical characteristics. In addition, the lingual aspect of the posterior mandible may present anatomical concavities that increase the complexity of ridge assessment and necessitate accurate evaluation of bone dimensions prior to the surgical procedures(6).

Accurate evaluation of buccolingual ridge dimensions is essential for reliable assessment of alveolar bone morphology. Inaccurate estimation of ridge width may result in discrepancies between radiographic findings and actual bone dimensions. Therefore, precise and reproducible measurement methods are required to ensure reliable assessment of alveolar ridge width, particularly in posterior mandibular regions where anatomical variations including lingual concavities and undercut are frequently encountered(5).

Conventional two-dimensional radiographic techniques, including panoramic and periapical radiography, have been widely used for assessment of alveolar bone. However, these imaging modalities have several limitations related to magnification, distortion, superimposition, and inability to evaluate the buccolingual dimension of the alveolar ridge. Such limitations may reduce the accuracy of linear measurements and compromise reliable assessment of bone morphology in posterior mandibular regions(7).

The inherent limitations of conventional two-dimensional imaging techniques have increased the demand for volumetric imaging modalities capable of providing accurate three-dimensional visualization of alveolar bone morphology. Three-dimensional imaging modality eliminates the superimposition and geometric distortion commonly associated with conventional radiography and enables precise multiplanar reconstruction of osseous structures in the axial, coronal, and sagittal planes(8).This capability enables more accurate assessment of the buccolingual dimension of the alveolar ridge and improves radiographic evaluation of anatomical structures in posterior mandibular regions. Consequently, volumetric imaging modalities have become increasingly important for accurate evaluation of alveolar bone dimensions and morphology(9).

Cone-beam computed tomography (CBCT) has become widely utilized in dentomaxillofacial imaging because of its ability to provide high-resolution three-dimensional images with relatively low radiation exposure compared with conventional computed tomography. CBCT enables accurate linear measurements of alveolar bone dimensions and facilitates detailed evaluation of anatomical structures relevant to implant site assessment and surgical planning(9).

Although CBCT has demonstrated high accuracy in assessment of alveolar bone dimensions, validation of CBCT-derived measurements under clinical conditions remains essential. Minor discrepancies between radiographic measurements and actual bone dimensions may still occur due to factors related to image acquisition, voxel size, observer variability, and image interpretation(10). Therefore, direct intraoperative measurements continue to be considered an important reference standard for evaluation of the accuracy and reproducibility of CBCT linear measurements(11).

Direct intraoperative measurements provide accurate assessment of alveolar bone dimensions and are considered the reference standard for validating radiographic measurements in clinical studies. The variations in measurement techniques, anatomical reference points, and imaging protocols may influence the reported accuracy of CBCT measurements. Consequently, further validation studies remain necessary to assess the reliability of CBCT measurements in anatomically variable posterior mandibular regions(12).

Although previous validation studies have reported favorable agreement between CBCT-derived measurements and direct intraoperative measurements in posterior mandibular implant sites, these studies have not employed standardized localization devices to ensure identical measurement points between the radiographic and surgical phases(12, 13). The absence of a standardized point localization method may introduce positional variability in reported measurements, potentially affecting the reliability of comparison outcomes(13). Ridge mapping by CBCT needs to be compared to what would seem to be the most accurate measurement, which is direct caliper measurement following surgical exposure of the bone(11, 14). Therefore, a validated measurement protocol incorporating a standardized stent-based localization device is required to ensure reproducible and accurate comparison between CBCT-derived and intraoperative ridge width measurements.

To the best of our knowledge, there are insufficient clinical studies that have compared CBCT-derived buccolingual ridge width measurements with direct intraoperative caliper measurements obtained at standardized levels corresponding to planned implant positions in posterior mandibular sites. Therefore, the aim of the present study is to validate the accuracy and reliability of buccolingual ridge width measurements obtained from cone-beam computed tomography (CBCT) by comparing them with direct intraoperative caliper measurements in posterior mandibular implant sites using a standardized stent-based localization protocol.

The null hypothesis of the present study is that there will be no statistically significant difference between buccolingual ridge width measurements obtained from CBCT and those obtained through direct intraoperative measurements at posterior mandibular implant sites.

Studietyp

Observationell

Inskrivning (Beräknad)

30

Kontakter och platser

Det här avsnittet innehåller kontaktuppgifter för dem som genomför studien och information om var denna studie genomförs.

Studiekontakt

Deltagandekriterier

Forskare letar efter personer som passar en viss beskrivning, så kallade behörighetskriterier. Några exempel på dessa kriterier är en persons allmänna hälsotillstånd eller tidigare behandlingar.

Urvalskriterier

Åldrar som är berättigade till studier

18 år och äldre (Vuxen, Äldre vuxen)

Tar emot friska volontärer

Nej

Kön som är behöriga för studier

Allt

Testmetod

Icke-sannolikhetsprov

Studera befolkning

Adults aged 18 years or older who are scheduled for single-tooth dental implant placement in the posterior mandible at a previously extracted mandibular first or second molar site. Participants must have sufficient post-extraction healing, identifiable buccolingual ridge morphology, and adequate residual alveolar bone dimensions for implant placement. Patients must be in good general health, have a stable periodontal condition without active inflammation, and meet all inclusion criteria while excluding those with conditions or factors that may interfere with implant surgery or bone healing.

Beskrivning

Inclusion Criteria:

  1. Site in Patients aged 18 years or above.
  2. Patients indicated for posterior mandibular implant placement at the site of a previously extracted mandibular first or second molar.
  3. Sufficient post-extraction healing time with preservation of identifiable buccolingual ridge morphology including lingual ridge contour.
  4. Adequate residual alveolar bone dimensions to permit implant placement.
  5. Patients in good general health with no systemic conditions contraindicated for implant surgery.
  6. Patients with stable periodontal condition and no signs of active inflammation.

Exclusion Criteria:

  1. History of malignancy or head and neck radiation therapy.
  2. Uncontrolled systemic diseases contraindicated for surgical procedures.
  3. Active periodontal infection or acute inflammation at the planned implant site.
  4. History of periodontal or bone augmentation surgery at the planned site.
  5. Parafunctional occlusal habits including bruxism or clenching.
  6. Pregnant or lactating females.
  7. Patients with smoking habits that may affect bone healing.
  8. Insufficient residual alveolar bone dimensions precluding implant placement without augmentation procedures.

Studieplan

Det här avsnittet ger detaljer om studieplanen, inklusive hur studien är utformad och vad studien mäter.

Hur är studien utformad?

Designdetaljer

  • Observationsmodeller: OTHER
  • Tidsperspektiv: PROSPECTIVE

Vad mäter studien?

Primära resultatmått

Resultatmått
Åtgärdsbeskrivning
Tidsram
Difference between CBCT-derived and direct intraoperative buccolingual ridge width
Tidsram: At the time of implant placement surgery (before implant placement

Mean difference, absolute difference, and agreement between buccolingual alveolar ridge width measured on CBCT cross-sectional images and direct intraoperative caliper measurements at the standardized stent-based planned implant position. Measurements will be recorded in millimeters (mm).

At the time of implant placement surgery (before implant placement

Sekundära resultatmått

Resultatmått
Åtgärdsbeskrivning
Tidsram
Interobserver and intraobserver reliability of CBCT buccolingual ridge-width measurements
Tidsram: At CBCT image analysis, before implant placement surgery

reproducibility of CBCT-derived buccolingual alveolar ridge-width measurements, assessed as intraobserver and interobserver agreement between repeated measurements by two independent calibrated examiners. Measurements will be recorded in millimeters (mm)."

At CBCT image analysis, before implant placement surgery

Samarbetspartners och utredare

Det är här du hittar personer och organisationer som är involverade i denna studie.

Utredare

  • Huvudutredare: Dr. Malak Youssef Mohammed, professor, Faculty of Dentistry, Tanta University, Egypt

Studieavstämningsdatum

Dessa datum spårar framstegen för inlämningar av studieposter och sammanfattande resultat till ClinicalTrials.gov. Studieposter och rapporterade resultat granskas av National Library of Medicine (NLM) för att säkerställa att de uppfyller specifika kvalitetskontrollstandarder innan de publiceras på den offentliga webbplatsen.

Studera stora datum

Studiestart (Beräknad)

1 november 2026

Primärt slutförande (Beräknad)

30 november 2027

Avslutad studie (Beräknad)

30 december 2027

Studieregistreringsdatum

Först inskickad

13 november 2026

Först inskickad som uppfyllde QC-kriterierna

13 november 2026

Första postat (Faktisk)

19 november 2026

Uppdateringar av studier

Senaste uppdatering publicerad (Faktisk)

19 november 2026

Senaste inskickade uppdateringen som uppfyllde QC-kriterierna

13 november 2026

Senast verifierad

1 november 2026

Mer information

Termer relaterade till denna studie

Andra studie-ID-nummer

  • Validation of CBCT measurement

Plan för individuella deltagardata (IPD)

Planerar du att dela individuella deltagardata (IPD)?

NEJ

Läkemedels- och apparatinformation, studiedokument

Studerar en amerikansk FDA-reglerad läkemedelsprodukt

Nej

Studerar en amerikansk FDA-reglerad produktprodukt

Nej

Denna information hämtades direkt från webbplatsen clinicaltrials.gov utan några ändringar. Om du har några önskemål om att ändra, ta bort eller uppdatera dina studieuppgifter, vänligen kontakta register@clinicaltrials.gov. Så snart en ändring har implementerats på clinicaltrials.gov, kommer denna att uppdateras automatiskt även på vår webbplats .

Prenumerera