Validation of Buccolingual Ridge Width Measurements on CBCT Using Direct Intraoperative Measurements
Validation of Buccolingual Ridge Width Measurements on CBCT Using Direct Intraoperative Measurements in The Posterior Mandible During Implant Placement.
This study aims to validate the accuracy of cone beam computed tomography (CBCT) in assessing buccolingual ridge width at posterior mandibular implant sites by comparing CBCT-derived measurements with standardized direct intraoperative caliper measurements obtained at the planned implant position.
研究概览
地位
详细说明
The alveolar ridge is a dynamic anatomical structure that undergoes continuous remodeling throughout life in response to functional and biological changes. Following tooth extraction, progressive dimensional alterations occur in the alveolar bone, resulting in reduction of ridge height and width. Several studies have demonstrated that post-extraction bone resorption predominantly affecting the buccolingual dimension, leading to changes in ridge morphology and contour(1, 2). These dimensional changes may complicate accurate radiographic and clinical assessment of the residual alveolar ridge(3).
The success of implant therapy is influenced by several endogenous and exogenous factors. Endogenous factors include the quality and quantity of the supporting alveolar bone, whereas exogenous factors include implant length, diameter, design, and surgical technique. Bone quality varies considerably among different regions of jaws. In general, the mandible demonstrates denser cortical bone than the maxilla, while posterior regions of both jaws tend to exhibit reduced cortical thickness and increased trabecular porosity(4). Therefore, accurate assessment of alveolar bone dimensions is considered a fundamental prerequisite for proper implant planning and successful treatment outcomes(5).
The posterior mandibular region exhibits considerable anatomical variability in alveolar ridge morphology and cortical bone configuration. Buccolingual ridge width in this region may be influenced by residual ridge resorption, cortical plate thickness, and individual anatomical characteristics. In addition, the lingual aspect of the posterior mandible may present anatomical concavities that increase the complexity of ridge assessment and necessitate accurate evaluation of bone dimensions prior to the surgical procedures(6).
Accurate evaluation of buccolingual ridge dimensions is essential for reliable assessment of alveolar bone morphology. Inaccurate estimation of ridge width may result in discrepancies between radiographic findings and actual bone dimensions. Therefore, precise and reproducible measurement methods are required to ensure reliable assessment of alveolar ridge width, particularly in posterior mandibular regions where anatomical variations including lingual concavities and undercut are frequently encountered(5).
Conventional two-dimensional radiographic techniques, including panoramic and periapical radiography, have been widely used for assessment of alveolar bone. However, these imaging modalities have several limitations related to magnification, distortion, superimposition, and inability to evaluate the buccolingual dimension of the alveolar ridge. Such limitations may reduce the accuracy of linear measurements and compromise reliable assessment of bone morphology in posterior mandibular regions(7).
The inherent limitations of conventional two-dimensional imaging techniques have increased the demand for volumetric imaging modalities capable of providing accurate three-dimensional visualization of alveolar bone morphology. Three-dimensional imaging modality eliminates the superimposition and geometric distortion commonly associated with conventional radiography and enables precise multiplanar reconstruction of osseous structures in the axial, coronal, and sagittal planes(8).This capability enables more accurate assessment of the buccolingual dimension of the alveolar ridge and improves radiographic evaluation of anatomical structures in posterior mandibular regions. Consequently, volumetric imaging modalities have become increasingly important for accurate evaluation of alveolar bone dimensions and morphology(9).
Cone-beam computed tomography (CBCT) has become widely utilized in dentomaxillofacial imaging because of its ability to provide high-resolution three-dimensional images with relatively low radiation exposure compared with conventional computed tomography. CBCT enables accurate linear measurements of alveolar bone dimensions and facilitates detailed evaluation of anatomical structures relevant to implant site assessment and surgical planning(9).
Although CBCT has demonstrated high accuracy in assessment of alveolar bone dimensions, validation of CBCT-derived measurements under clinical conditions remains essential. Minor discrepancies between radiographic measurements and actual bone dimensions may still occur due to factors related to image acquisition, voxel size, observer variability, and image interpretation(10). Therefore, direct intraoperative measurements continue to be considered an important reference standard for evaluation of the accuracy and reproducibility of CBCT linear measurements(11).
Direct intraoperative measurements provide accurate assessment of alveolar bone dimensions and are considered the reference standard for validating radiographic measurements in clinical studies. The variations in measurement techniques, anatomical reference points, and imaging protocols may influence the reported accuracy of CBCT measurements. Consequently, further validation studies remain necessary to assess the reliability of CBCT measurements in anatomically variable posterior mandibular regions(12).
Although previous validation studies have reported favorable agreement between CBCT-derived measurements and direct intraoperative measurements in posterior mandibular implant sites, these studies have not employed standardized localization devices to ensure identical measurement points between the radiographic and surgical phases(12, 13). The absence of a standardized point localization method may introduce positional variability in reported measurements, potentially affecting the reliability of comparison outcomes(13). Ridge mapping by CBCT needs to be compared to what would seem to be the most accurate measurement, which is direct caliper measurement following surgical exposure of the bone(11, 14). Therefore, a validated measurement protocol incorporating a standardized stent-based localization device is required to ensure reproducible and accurate comparison between CBCT-derived and intraoperative ridge width measurements.
To the best of our knowledge, there are insufficient clinical studies that have compared CBCT-derived buccolingual ridge width measurements with direct intraoperative caliper measurements obtained at standardized levels corresponding to planned implant positions in posterior mandibular sites. Therefore, the aim of the present study is to validate the accuracy and reliability of buccolingual ridge width measurements obtained from cone-beam computed tomography (CBCT) by comparing them with direct intraoperative caliper measurements in posterior mandibular implant sites using a standardized stent-based localization protocol.
The null hypothesis of the present study is that there will be no statistically significant difference between buccolingual ridge width measurements obtained from CBCT and those obtained through direct intraoperative measurements at posterior mandibular implant sites.
研究类型
注册 (估计的)
联系人和位置
学习联系方式
- 姓名:Nayra Mohammed zaki, master degree=
- 电话号码:+201205233092
- 邮箱:PG_198213@dent.tanta.edu.eg
参与标准
资格标准
适合学习的年龄
接受健康志愿者
有资格学习的性别
取样方法
研究人群
Adults aged 18 years or older who are scheduled for single-tooth dental implant placement in the posterior mandible at a previously extracted mandibular first or second molar site. Participants must have sufficient post-extraction healing, identifiable buccolingual ridge morphology, and adequate residual alveolar bone dimensions for implant placement. Patients must be in good general health, have a stable periodontal condition without active inflammation, and meet all inclusion criteria while excluding those with conditions or factors that may interfere with implant surgery or bone healing.
描述
Inclusion Criteria:
- Site in Patients aged 18 years or above.
- Patients indicated for posterior mandibular implant placement at the site of a previously extracted mandibular first or second molar.
- Sufficient post-extraction healing time with preservation of identifiable buccolingual ridge morphology including lingual ridge contour.
- Adequate residual alveolar bone dimensions to permit implant placement.
- Patients in good general health with no systemic conditions contraindicated for implant surgery.
- Patients with stable periodontal condition and no signs of active inflammation.
Exclusion Criteria:
- History of malignancy or head and neck radiation therapy.
- Uncontrolled systemic diseases contraindicated for surgical procedures.
- Active periodontal infection or acute inflammation at the planned implant site.
- History of periodontal or bone augmentation surgery at the planned site.
- Parafunctional occlusal habits including bruxism or clenching.
- Pregnant or lactating females.
- Patients with smoking habits that may affect bone healing.
- Insufficient residual alveolar bone dimensions precluding implant placement without augmentation procedures.
学习计划
研究是如何设计的?
设计细节
- 观测模型:OTHER
- 时间观点:PROSPECTIVE
研究衡量的是什么?
主要结果指标
结果测量 |
措施说明 |
大体时间 |
|---|---|---|
|
Difference between CBCT-derived and direct intraoperative buccolingual ridge width
大体时间:At the time of implant placement surgery (before implant placement
|
Mean difference, absolute difference, and agreement between buccolingual alveolar ridge width measured on CBCT cross-sectional images and direct intraoperative caliper measurements at the standardized stent-based planned implant position. Measurements will be recorded in millimeters (mm). |
At the time of implant placement surgery (before implant placement
|
次要结果测量
结果测量 |
措施说明 |
大体时间 |
|---|---|---|
|
Interobserver and intraobserver reliability of CBCT buccolingual ridge-width measurements
大体时间:At CBCT image analysis, before implant placement surgery
|
reproducibility of CBCT-derived buccolingual alveolar ridge-width measurements, assessed as intraobserver and interobserver agreement between repeated measurements by two independent calibrated examiners. Measurements will be recorded in millimeters (mm)." |
At CBCT image analysis, before implant placement surgery
|
合作者和调查者
调查人员
- 首席研究员:Dr. Malak Youssef Mohammed, professor、Faculty of Dentistry, Tanta University, Egypt
研究记录日期
研究主要日期
学习开始 (估计的)
初级完成 (估计的)
研究完成 (估计的)
研究注册日期
首次提交
首先提交符合 QC 标准的
首次发布 (实际的)
研究记录更新
最后更新发布 (实际的)
上次提交的符合 QC 标准的更新
最后验证
更多信息
与本研究相关的术语
其他研究编号
- Validation of CBCT measurement
计划个人参与者数据 (IPD)
计划共享个人参与者数据 (IPD)?
药物和器械信息、研究文件
研究美国 FDA 监管的药品
研究美国 FDA 监管的设备产品
此信息直接从 clinicaltrials.gov 网站检索,没有任何更改。如果您有任何更改、删除或更新研究详细信息的请求,请联系 register@clinicaltrials.gov. clinicaltrials.gov 上实施更改,我们的网站上也会自动更新.