Denne siden ble automatisk oversatt og nøyaktigheten av oversettelsen er ikke garantert. Vennligst referer til engelsk versjon for en kildetekst.

Pulse Diagnosis of Traditional Chinese Medicine

29. april 2021 oppdatert av: Taipei Veterans General Hospital, Taiwan

To Develop Pulse Diagnosis of Traditional Chinese Medicine by Deep Learning.

Taking pulse as a disease diagnosis process has a long history in traditional Chinese medicine (TCM). Ancient physicians used the common attributes of pulse conditions and finger-feeling characteristics as a basis for pulse classification, which " position, rate, shape and tendency " is the principle for pulse differentiation. However, it is not easy to express feelings of hands in a scientific way and not easy for clinical teaching and practice.

To develope a new direction of pulse diagnosis in TCM by deep learning and integrative time-frequency domain analysis maybe can be solved the problem.

Studieoversikt

Status

Rekruttering

Forhold

Detaljert beskrivelse

Taking pulse as a disease diagnosis process has a long history in traditional Chinese medicine (TCM). Ancient physicians used the common attributes of pulse conditions and finger-feeling characteristics as a basis for pulse classification, which " position, rate, shape and tendency " is the principle for pulse differentiation. However, it is not easy to express feelings of hands in a scientific way and not easy for clinical teaching and practice. The modernization of pulse diagnosis in Taiwan originated in the 1970s. By using pressure waves of the radial artery, two methods were developed : time-domain analysis and frequency domain analysis. Dr. Huang used time-domain analysis combined with frequency-domain analysis of 6-sec pulse waves, to quantify 28 pulse patterns in TCM. Professor Wang measured a single pulse wave and performed Fourier transformation to obtain the corresponding 12 meridian frequency spectrum, but it is very different from the clinical practice of pulse diagnosis. Our team found that the frequency-domain and the tim-domain analysis can be integrated if Fourier transformation integral formula is applied. Because the extracted data is big, the characteristic values of time and frequency domain analysis are calculated and judged by deep learning method.

The purpose of this study is to use the " Integration analysis of time-domain" method to extract the characteristic values of the radial pulse, and then use deep learning for model training. That is, after measuring the pulse waves at different positions and depths of the bilateral radial arteries, by using the pulse diagnostic instrument, to initial signal processing and to get a single pulse. Then Fourier transformation is performed to obtain the magnitude and phase parameters of the 12 harmonics (24 variables in total), and then extract 7 time-domain characteristic parameters of a single pulse. The next step to perform Fourier transformation again using the 6-second pulse waves to obtain high and low frequency spectrum by using above parameters. The feature parameters obtained by the above two analysis methods are simultaneously sent to the deep learning-convolution neuron network (CNN) training. Since the pulse wave changes of the radial artery are related to time, CNN combined with long-short-term memory work (LSTM) is also used to do the above-mentioned model training. It is set to compare the differences between the pulse waves of healthy subjects and subjects with the suboptimal health status. It is also proved whether the frequency-domain analysis analysis method by Professor Wang and the time-domain analysis method by Dr. Huang is the same through the deep learning training process. It is possible to develope a new direction of pulse diagnosis in TCM by deep learning and integrative time-frequency domain analysis.

Studietype

Observasjonsmessig

Registrering (Forventet)

100

Kontakter og plasseringer

Denne delen inneholder kontaktinformasjon for de som utfører studien, og informasjon om hvor denne studien blir utført.

Studiekontakt

Studiesteder

      • Taipei, Taiwan, 112
        • Rekruttering
        • Center for Traditional Medicine, Taipei Veterans General Hospital

Deltakelseskriterier

Forskere ser etter personer som passer til en bestemt beskrivelse, kalt kvalifikasjonskriterier. Noen eksempler på disse kriteriene er en persons generelle helsetilstand eller tidligere behandlinger.

Kvalifikasjonskriterier

Alder som er kvalifisert for studier

20 år til 70 år (Voksen, Eldre voksen)

Tar imot friske frivillige

N/A

Kjønn som er kvalifisert for studier

Alle

Prøvetakingsmetode

Ikke-sannsynlighetsprøve

Studiepopulasjon

"Sub-healthy state" is defined as a condition where there is no illness but unhealthy. It causes abnormal psychological and physiological changes under internal and external environmental stimulation, but it has not yet reached the level of obvious pathological response.

Beskrivelse

Inclusion Criteria:

People who do not have a clear diagnosis of chronic diseases by Western medicine

Exclusion Criteria:

  1. Western medicine confirms the diagnosis of chronic diseases, such as high blood pressure, diabetes, chronic hepatitis, chronic kidney disease, chronic hyperlipidemia, coronary heart disease, etc.
  2. There is a clear diagnosis of mental illness by Western medicine
  3. Cancer patients

Studieplan

Denne delen gir detaljer om studieplanen, inkludert hvordan studien er utformet og hva studien måler.

Hvordan er studiet utformet?

Designdetaljer

Hva måler studien?

Primære resultatmål

Resultatmål
Tiltaksbeskrivelse
Tidsramme
"Skylark" Pulse Analysis System
Tidsramme: 6 second
That is, after measuring the pulse waves at different positions and depths of the bilateral radial arteries, by using the pulse diagnostic instrument, to initial signal processing and to get a single pulse. Then Fourier transformation is performed to obtain the magnitude and phase parameters of the 12 harmonics (24 variables in total), and then extract 7 time-domain characteristic parameters of a single pulse. The next step to perform Fourier transformation again using the 6-second pulse waves to obtain high and low frequency spectrum by using above parameters. The feature parameters obtained by the above two analysis methods are simultaneously sent to the deep learning-convolution neuron network (CNN) training.
6 second

Samarbeidspartnere og etterforskere

Det er her du vil finne personer og organisasjoner som er involvert i denne studien.

Etterforskere

  • Studieleder: Yen-Ying Yen-Ying, MD, Taipei Veterans General Hospital Center for Traditional Medicine

Studierekorddatoer

Disse datoene sporer fremdriften for innsending av studieposter og sammendragsresultater til ClinicalTrials.gov. Studieposter og rapporterte resultater gjennomgås av National Library of Medicine (NLM) for å sikre at de oppfyller spesifikke kvalitetskontrollstandarder før de legges ut på det offentlige nettstedet.

Studer hoveddatoer

Studiestart (Faktiske)

17. februar 2021

Primær fullføring (Forventet)

5. mai 2021

Studiet fullført (Forventet)

5. januar 2022

Datoer for studieregistrering

Først innsendt

14. mars 2021

Først innsendt som oppfylte QC-kriteriene

14. mars 2021

Først lagt ut (Faktiske)

16. mars 2021

Oppdateringer av studieposter

Sist oppdatering lagt ut (Faktiske)

30. april 2021

Siste oppdatering sendt inn som oppfylte QC-kriteriene

29. april 2021

Sist bekreftet

1. april 2021

Mer informasjon

Begreper knyttet til denne studien

Andre studie-ID-numre

  • 2020-12-015CC

Legemiddel- og utstyrsinformasjon, studiedokumenter

Studerer et amerikansk FDA-regulert medikamentprodukt

Nei

Studerer et amerikansk FDA-regulert enhetsprodukt

Nei

Denne informasjonen ble hentet direkte fra nettstedet clinicaltrials.gov uten noen endringer. Hvis du har noen forespørsler om å endre, fjerne eller oppdatere studiedetaljene dine, vennligst kontakt register@clinicaltrials.gov. Så snart en endring er implementert på clinicaltrials.gov, vil denne også bli oppdatert automatisk på nettstedet vårt. .

Abonnere