- ICH GCP
- US Clinical Trials Registry
- Klinisk utprøving NCT07795138
Comparative Effect of Conventional and 3D-printed Twin Block Appliances on Soft Tissue Changes (Clinic Radiogr)
Studieoversikt
Detaljert beskrivelse
Background: Enhancing facial aesthetics is the main target of orthodontic treatment, as appearance greatly influences a person's social confidence and self-esteem. Skeletal Class II malocclusion is quite common, and the pubertal growth spurt is the perfect time for functional treatment to promote mandibular advancement. The Twin-Block, one of the most widely used functional appliances, is a popular choice for achieving this goal..
Patients and methods: Twenty patients divided into two groups with mixed or early permanent dentition were enrolled. Lateral cephalometric radiographs were taken at the start (T0; before treatment) and end (T1; at the end of the active phase) using the same machine. Those of each patient treated with a conventional Twin Block appliance for class II malocclusion were compared to those of patients treated with a 3D-printed Twin Block appliance for a 6-month follow-up period. Both groups were evaluated for soft tissue changes using various angular and linear geometric measurements, and differences between pre- and post-treatment were analyzed with a paired t-test.
Studietype
Registrering (Faktiske)
Fase
- Fase 1
Kontakter og plasseringer
Studiesteder
-
-
-
Asyut, Egypt, 0000
- Faculty of Dental Medicine,Al-Azhar University
-
-
Deltakelseskriterier
Kvalifikasjonskriterier
Alder som er kvalifisert for studier
- Barn
Tar imot friske frivillige
Beskrivelse
Inclusion Criteria:
- Young, growing age
- Class II malocclusion
- Increased overjet.
Exclusion Criteria:
- Severe proclination of anterior teeth.
- Severe crowding of anterior teeth.
- Systemic disease affecting bone and growth.
Studieplan
Hvordan er studiet utformet?
Designdetaljer
- Primært formål: Screening
- Tildeling: Ikke-randomisert
- Intervensjonsmodell: Parallell tildeling
- Masking: Trippel
Våpen og intervensjoner
Deltakergruppe / Arm |
Intervensjon / Behandling |
|---|---|
|
Eksperimentell: Group 1
ten Patients treated using a conventional twin block appliance
|
Functional Device
|
|
Aktiv komparator: Group 2
ten Patients treated using a 3-D printed twin block appliance
|
Functional Device
|
Hva måler studien?
Primære resultatmål
Resultatmål |
Tiltaksbeskrivelse |
Tidsramme |
|---|---|---|
|
Lateral cephalometric radiographs
Tidsramme: Baseline and 6 months after treatment
|
angular degree
|
Baseline and 6 months after treatment
|
|
Lateral cephalometric radiographs
Tidsramme: Baseline and 6 months after treatment
|
linear measurements by mm
|
Baseline and 6 months after treatment
|
Samarbeidspartnere og etterforskere
Sponsor
Publikasjoner og nyttige lenker
Hjelpsomme linker
Studierekorddatoer
Studer hoveddatoer
Studiestart (Faktiske)
Primær fullføring (Faktiske)
Studiet fullført (Faktiske)
Datoer for studieregistrering
Først innsendt
Først innsendt som oppfylte QC-kriteriene
Først lagt ut (Faktiske)
Oppdateringer av studieposter
Sist oppdatering lagt ut (Faktiske)
Siste oppdatering sendt inn som oppfylte QC-kriteriene
Sist bekreftet
Mer informasjon
Begreper knyttet til denne studien
Nøkkelord
Ytterligere relevante MeSH-vilkår
Andre studie-ID-numre
- AUARC20240003-7
Legemiddel- og utstyrsinformasjon, studiedokumenter
Studerer et amerikansk FDA-regulert medikamentprodukt
Studerer et amerikansk FDA-regulert enhetsprodukt
Denne informasjonen ble hentet direkte fra nettstedet clinicaltrials.gov uten noen endringer. Hvis du har noen forespørsler om å endre, fjerne eller oppdatere studiedetaljene dine, vennligst kontakt register@clinicaltrials.gov. Så snart en endring er implementert på clinicaltrials.gov, vil denne også bli oppdatert automatisk på nettstedet vårt. .