Denna sida har översatts automatiskt och översättningens korrekthet kan inte garanteras. Vänligen se engelsk version för en källtext.

Comparison of the Diagnostic Accuracy Between Three Dimensional and Standard Colonoscopy of Colorectal Polyps

28 maj 2026 uppdaterad av: National Taiwan University Hospital

Colorectal cancer (CRC) is one of the most common cancers worldwide. These malignancies originate in the colon or rectum, and the majority evolve from pre-existing colonic adenomas (a type of colon polyp). Early detection, identification, and removal of these precancerous lesions can effectively reduce the morbidity and mortality of colorectal cancer.

However, not all colonic polyps possess a significant risk of malignant transformation. Polyps can generally be subdivided into "neoplastic" and "non-neoplastic" lesions; major non-neoplastic polyps include inflammatory polyps, hamartomas, lymphoid polyps, mucosal prolapse polyps, and hyperplastic polyps. On the other hand, neoplastic polyps have the potential to develop into malignancies, primarily including adenomatous polyps and serrated polyps. Adenomatous polyps account for more than 50% of all colonic polyps and are the most common precancerous lesions for CRC. Clinically, they can be further classified into tubular, tubulovillous, or villous adenomas based on histological subtypes. As for serrated polyps, traditional serrated adenomas (TSAs) and sessile serrated lesions (SSLs) possess carcinogenic potential.

During a colonoscopy, detecting colonic polyps is crucial, but it is equally important to identify which polyps have malignant potential. This allows for the accurate resection of true precancerous lesions while avoiding the procedural risks associated with unnecessary polypectomies. Furthermore, in rare instances, diminutive polyps may harbor cancer with deep submucosal invasion. Due to the risks of incomplete resection and lymph node metastasis, such lesions are not suitable for endoscopic resection. Therefore, achieving an accurate endoscopic diagnosis is a key step in determining the most appropriate management strategy for colonic polyps.

To improve the diagnostic accuracy of endoscopy for colonic polyps, multiple modalities have been developed, including careful observation of lesion morphology, as well as various image-enhanced technologies and chromoendoscopy. Meanwhile, three-dimensional (3D) endoscopy, a novel technology, offers superior spatial resolution and depth perception compared to conventional two-dimensional (2D) endoscopy. Studies have confirmed that 3D endoscopy can improve the adenoma detection rate (ADR) due to its enhanced ability to detect flat and inconspicuous lesions. However, whether 3D colonoscopy can also enhance the endoscopic diagnostic accuracy for colonic polyps remains to be explored. Therefore, we designed a randomized controlled trial (RCT) to investigate whether 3D colonoscopy can improve the diagnostic accuracy of colonic polyps compared to conventional 2D colonoscopy.

Studieöversikt

Status

Har inte rekryterat ännu

Intervention / Behandling

Detaljerad beskrivning

Colorectal cancer (CRC) is one of the most common cancers worldwide. These malignancies originate in the colon or rectum, and the majority evolve from pre-existing colonic adenomas (a type of colon polyp). Early detection, identification, and removal of these precancerous lesions can effectively reduce the morbidity and mortality of colorectal cancer.

However, not all colonic polyps possess a significant risk of malignant transformation. Polyps can generally be subdivided into "neoplastic" and "non-neoplastic" lesions; major non-neoplastic polyps include inflammatory polyps, hamartomas, lymphoid polyps, mucosal prolapse polyps, and hyperplastic polyps. On the other hand, neoplastic polyps have the potential to develop into malignancies, primarily including adenomatous polyps and serrated polyps. Adenomatous polyps account for more than 50% of all colonic polyps and are the most common precancerous lesions for CRC. Clinically, they can be further classified into tubular, tubulovillous, or villous adenomas based on histological subtypes. As for serrated polyps, traditional serrated adenomas (TSAs) and sessile serrated lesions (SSLs) possess carcinogenic potential.

During a colonoscopy, detecting colonic polyps is crucial, but it is equally important to identify which polyps have malignant potential. This allows for the accurate resection of true precancerous lesions while avoiding the procedural risks associated with unnecessary polypectomies. Furthermore, in rare instances, diminutive polyps may harbor cancer with deep submucosal invasion. Due to the risks of incomplete resection and lymph node metastasis, such lesions are not suitable for endoscopic resection. Therefore, achieving an accurate endoscopic diagnosis is a key step in determining the most appropriate management strategy for colonic polyps.

To improve the diagnostic accuracy of endoscopy for colonic polyps, multiple modalities have been developed, including careful observation of lesion morphology, as well as various image-enhanced technologies and chromoendoscopy. Meanwhile, three-dimensional (3D) endoscopy, a novel technology, offers superior spatial resolution and depth perception compared to conventional two-dimensional (2D) endoscopy. Studies have confirmed that 3D endoscopy can improve the adenoma detection rate (ADR) due to its enhanced ability to detect flat and inconspicuous lesions. However, whether 3D colonoscopy can also enhance the endoscopic diagnostic accuracy for colonic polyps remains to be explored. Therefore, we designed a randomized controlled trial (RCT) to investigate whether 3D colonoscopy can improve the diagnostic accuracy of colonic polyps compared to conventional 2D colonoscopy.

This study is a single-country, multicenter randomized controlled trial (RCT), expected to be conducted at National Taiwan University Hospital, National Taiwan University Cancer Center, NTUH Hsinchu Branch, and Chia-Yi Christian Hospital. The trial includes an experimental group (observed first with 3D endoscopy, then with conventional 2D endoscopy) and a control group (observed first with conventional 2D endoscopy, then with 3D endoscopy). As an exploratory study, we plan to enroll 600 adults aged 18 and above undergoing colonoscopy, randomized in a 1:1 ratio into the experimental and control groups. All endoscopists participating in this research project have extensive endoscopic experience, performing at least 100 polypectomies annually. Informed consent will be obtained in the outpatient clinic and the endoscopy center. When a patient requires a colonoscopy, the principal investigator will inquire about their willingness to join the clinical study in the clinic or the endoscopy room. If the subject is willing to participate, a research assistant will help explain the study and assist with the signing of the informed consent form.

When subjects undergo the colonoscopy, the operator will use the conventional 2D endoscopic mode for insertion. Once the colonoscope reaches the cecum, a research assistant will randomly assign the subject to one of the two endoscopic modality sequences using a sealed envelope, with an expected 1:1 allocation ratio between the two groups. The primary difference between the two groups occurs during the withdrawal of the endoscope from the cecum to the anus. If a polyp lesion is detected, one group will first use conventional 2D imaging for polyp diagnosis, and then switch to 3D endoscopy for a second diagnosis. The other group will do the reverse: completing the diagnosis with 3D endoscopy first, and then switching to conventional 2D endoscopy for a second diagnosis. This design aims to eliminate judgment bias caused by the diagnostic sequence. The resected polyps will be sent to the pathology department for histopathological examination. Subsequently, the pathological diagnosis will be compared with both the 3D and 2D endoscopic diagnoses to determine the endoscopic diagnostic accuracy for each, defined as the diagnostic consistency rate between the endoscopic and pathological diagnoses. Regardless of the subject's assigned group, the operator will utilize other image-enhanced techniques (such as NBI or chromoendoscopy) and perform polypectomies according to routine clinical practice during the withdrawal phase.

Endpoints:

Primary Endpoints: The primary endpoint of this study is to compare the diagnosis accuracy rate (DAR) of polyps under different endoscopic modes to determine if there is a significant difference between 3D and 2D colonoscopy. This is primarily calculated by comparing the pathological diagnosis of the resected polyps sent for laboratory testing with the 3D and 2D endoscopic diagnoses, which represents the diagnostic consistency rate. In practical application, each polyp will receive a 3D diagnosis and a 2D diagnosis (regardless of the order), as well as a pathological diagnosis. If the 3D diagnosis of a polyp aligns with the pathological diagnosis, it is considered a correct diagnosis; otherwise, it is deemed incorrect. The DAR is the proportion of correct diagnoses out of the total number of polyps analyzed.

Secondary Endpoints: The secondary endpoints will evaluate the diagnosis alternation rate, which is the frequency of inconsistent endoscopic diagnoses for the same polyp when utilizing different observation methods. Additionally, the impact of factors such as the sizes of polyps, morphology of polyps, and location of polyps on the aforementioned DAR will be assessed. Furthermore, we will compare the incidence of complications and the differences in procedure time between the different endoscopic modes.

Studietyp

Interventionell

Inskrivning (Beräknad)

600

Fas

  • Inte tillämpbar

Kontakter och platser

Det här avsnittet innehåller kontaktuppgifter för dem som genomför studien och information om var denna studie genomförs.

Studiekontakt

Deltagandekriterier

Forskare letar efter personer som passar en viss beskrivning, så kallade behörighetskriterier. Några exempel på dessa kriterier är en persons allmänna hälsotillstånd eller tidigare behandlingar.

Urvalskriterier

Åldrar som är berättigade till studier

  • Vuxen
  • Äldre vuxen

Tar emot friska volontärer

Nej

Beskrivning

Inclusion Criteria:

  • Patients aged 18 years or older.
  • Patients who meet the indications for undergoing colonoscopy.

Exclusion Criteria:

  • Patients younger than 18 years of age or those with contraindications precluding them from undergoing a colonoscopy.

(Contraindications for colonoscopy: patients with a recent history of myocardial infarction, pulmonary embolism, cerebrovascular infarction, severe unstable cardiovascular disease, acute abdominal inflammation combined with peritonitis, fulminant colitis, acute diverticulitis, colonic perforation, or toxic megacolon).

  • Patients with familial hereditary colorectal cancer or colonic polyposis syndromes.
  • Patients with inflammatory bowel disease (IBD).
  • Subjects who are unable to complete the colonoscopy or those with poor bowel preparation.
  • Subjects who are unable to confirm the date of their previous colonoscopy.

Studieplan

Det här avsnittet ger detaljer om studieplanen, inklusive hur studien är utformad och vad studien mäter.

Hur är studien utformad?

Designdetaljer

  • Primärt syfte: Diagnostisk
  • Tilldelning: Randomiserad
  • Interventionsmodell: Parallellt uppdrag
  • Maskning: Ingen (Open Label)

Vapen och interventioner

Deltagargrupp / Arm
Intervention / Behandling
Experimentell: 2D-3D sequence
When subjects undergo the colonoscopy, the operator will use the conventional 2D endoscopic mode for insertion. Once the colonoscope reaches the cecum, a research assistant will randomly assign the subject to one of the two endoscopic modality sequences using a sealed envelope, with an expected 1:1 allocation ratio between the two groups. The primary difference between the two groups occurs during the withdrawal of the endoscope from the cecum to the anus. If a polyp lesion is detected, one group will first use conventional 2D imaging for polyp diagnosis, and then switch to 3D endoscopy for a second diagnosis. The other group will do the reverse: completing the diagnosis with 3D endoscopy first, and then switching to conventional 2D endoscopy for a second diagnosis. This design aims to eliminate judgment bias caused by the diagnostic sequence.
When subjects undergo the colonoscopy, the operator will use the conventional 2D endoscopic mode for insertion. Once the colonoscope reaches the cecum, a research assistant will randomly assign the subject to one of the two endoscopic modality sequences using a sealed envelope, with an expected 1:1 allocation ratio between the two groups. The primary difference between the two groups occurs during the withdrawal of the endoscope from the cecum to the anus. If a polyp lesion is detected, one group will first use conventional 2D imaging for polyp diagnosis, and then switch to 3D endoscopy for a second diagnosis. The other group will do the reverse: completing the diagnosis with 3D endoscopy first, and then switching to conventional 2D endoscopy for a second diagnosis. This design aims to eliminate judgment bias caused by the diagnostic sequence.
Övrig: 3D-2D sequence
When subjects undergo the colonoscopy, the operator will use the conventional 2D endoscopic mode for insertion. Once the colonoscope reaches the cecum, a research assistant will randomly assign the subject to one of the two endoscopic modality sequences using a sealed envelope, with an expected 1:1 allocation ratio between the two groups. The primary difference between the two groups occurs during the withdrawal of the endoscope from the cecum to the anus. If a polyp lesion is detected, one group will first use conventional 2D imaging for polyp diagnosis, and then switch to 3D endoscopy for a second diagnosis. The other group will do the reverse: completing the diagnosis with 3D endoscopy first, and then switching to conventional 2D endoscopy for a second diagnosis. This design aims to eliminate judgment bias caused by the diagnostic sequence.
When subjects undergo the colonoscopy, the operator will use the conventional 2D endoscopic mode for insertion. Once the colonoscope reaches the cecum, a research assistant will randomly assign the subject to one of the two endoscopic modality sequences using a sealed envelope, with an expected 1:1 allocation ratio between the two groups. The primary difference between the two groups occurs during the withdrawal of the endoscope from the cecum to the anus. If a polyp lesion is detected, one group will first use conventional 2D imaging for polyp diagnosis, and then switch to 3D endoscopy for a second diagnosis. The other group will do the reverse: completing the diagnosis with 3D endoscopy first, and then switching to conventional 2D endoscopy for a second diagnosis. This design aims to eliminate judgment bias caused by the diagnostic sequence.

Vad mäter studien?

Primära resultatmått

Resultatmått
Åtgärdsbeskrivning
Tidsram
diagnosis accuracy rate (DAR) of polyps under different endoscopic modes
Tidsram: 12 months
Primary Endpoints: The primary endpoint of this study is to compare the diagnosis accuracy rate (DAR) of polyps under different endoscopic modes to determine if there is a significant difference between 3D and 2D colonoscopy. This is primarily calculated by comparing the pathological diagnosis of the resected polyps sent for laboratory testing with the 3D and 2D endoscopic diagnoses, which represents the diagnostic consistency rate. In practical application, each polyp will receive a 3D diagnosis and a 2D diagnosis (regardless of the order), as well as a pathological diagnosis. If the 3D diagnosis of a polyp aligns with the pathological diagnosis, it is considered a correct diagnosis; otherwise, it is deemed incorrect. The DAR is the proportion of correct diagnoses out of the total number of polyps analyzed.
12 months

Samarbetspartners och utredare

Det är här du hittar personer och organisationer som är involverade i denna studie.

Studieavstämningsdatum

Dessa datum spårar framstegen för inlämningar av studieposter och sammanfattande resultat till ClinicalTrials.gov. Studieposter och rapporterade resultat granskas av National Library of Medicine (NLM) för att säkerställa att de uppfyller specifika kvalitetskontrollstandarder innan de publiceras på den offentliga webbplatsen.

Studera stora datum

Studiestart (Beräknad)

12 maj 2026

Primärt slutförande (Beräknad)

12 maj 2027

Avslutad studie (Beräknad)

12 maj 2027

Studieregistreringsdatum

Först inskickad

19 maj 2026

Först inskickad som uppfyllde QC-kriterierna

28 maj 2026

Första postat (Faktisk)

1 juni 2026

Uppdateringar av studier

Senaste uppdatering publicerad (Faktisk)

1 juni 2026

Senaste inskickade uppdateringen som uppfyllde QC-kriterierna

28 maj 2026

Senast verifierad

1 maj 2026

Mer information

Termer relaterade till denna studie

Andra studie-ID-nummer

  • 202603028DIPD

Plan för individuella deltagardata (IPD)

Planerar du att dela individuella deltagardata (IPD)?

NEJ

Läkemedels- och apparatinformation, studiedokument

Studerar en amerikansk FDA-reglerad läkemedelsprodukt

Nej

Studerar en amerikansk FDA-reglerad produktprodukt

Nej

Denna information hämtades direkt från webbplatsen clinicaltrials.gov utan några ändringar. Om du har några önskemål om att ändra, ta bort eller uppdatera dina studieuppgifter, vänligen kontakta register@clinicaltrials.gov. Så snart en ändring har implementerats på clinicaltrials.gov, kommer denna att uppdateras automatiskt även på vår webbplats .

Prenumerera