Local Warming to Improve Pulse Oximetry Accuracy in Critically Ill Patients (PULSEWARM)

24 augusti 2026 uppdaterad av: Carl Sjödin, Vastra Gotaland Region

Effect of Local Warming on Pulse Oximetry Accuracy in Critically Ill Patients With Low Peripheral Perfusion: A Multicenter Randomized Controlled Trial

Pulse oximeters are widely used in intensive care to continuously estimate the oxygen level in the blood. However, pulse oximeter measurements may be less accurate when blood flow to the fingers is poor, which is common in critically ill patients.

This study will investigate whether warming the hand and lower part of the forearm can improve the accuracy of pulse oximeter measurements in mechanically ventilated adult intensive care patients with low blood flow to the fingers.

Participants will be randomly assigned to either a local warming strategy or usual care without warming. In the warming group, the hand and lower forearm will be warmed for 15 minutes to a target temperature of 41-42°C. Pulse oximeter measurements will be compared with oxygen saturation measured from an arterial blood sample before and after the intervention.

The main objective is to determine whether local warming reduces the difference between pulse oximeter oxygen saturation (SpO₂) and arterial oxygen saturation (SaO₂) 15 minutes after the start of the assigned strategy. The study will also assess whether any improvement persists at 60 minutes, how peripheral blood flow changes during 4 hours of follow-up, whether repeat warming is effective when blood flow decreases again, and whether the effect differs according to skin phototype. Safety related to the warming intervention will also be evaluated.

Studieöversikt

Status

Har inte rekryterat ännu

Intervention / Behandling

Detaljerad beskrivning

Pulse oximetry is a fundamental component of monitoring and oxygen titration in critically ill patients. Its accuracy may, however, be impaired by reduced peripheral perfusion. Low peripheral perfusion is common in mechanically ventilated intensive care patients and may contribute to clinically relevant differences between peripheral oxygen saturation measured by pulse oximetry (SpO₂) and arterial oxygen saturation measured by blood gas analysis (SaO₂).

Local warming increases cutaneous blood flow and is routinely used to improve peripheral perfusion during procedures such as capillary blood sampling. Preliminary single-center data suggest that local warming may also improve pulse oximetry accuracy in critically ill patients with low peripheral perfusion. Whether this effect is present when evaluated in a randomized controlled trial is unknown.

This is a prospective, multicenter, parallel-group randomized controlled strategy trial conducted in four intensive care units. Mechanically ventilated adult ICU patients with an arterial catheter and a finger perfusion index (PFI) <1.0 will be randomized in a 1:1 ratio to a protocolized local warming strategy or usual care without protocolized warming. Randomization will be stratified by study site and Fitzpatrick skin phototype.

In the intervention group, local warming will be applied to the dorsum of the hand and distal forearm for 15 minutes, with a target interface temperature of 41-42°C. Repeat warming is permitted during follow-up if finger PFI decreases below 0.5 according to the prespecified study strategy. The control group will receive usual care without protocolized local warming.

SpO₂, finger PFI, earlobe PFI, and arterial SaO₂ will be assessed at baseline, 15 minutes, and 60 minutes. Additional PFI measurements will be obtained at 120 and 240 minutes. Oxygen therapy will otherwise be managed according to standard clinical care.

The primary objective is to compare pulse oximetry bias between the randomized groups at 15 minutes. Bias is defined as SpO₂ minus SaO₂, expressed in percentage points. The primary analysis will compare the groups using an analysis of covariance adjusted for baseline SpO₂-SaO₂ bias and study site.

Secondary objectives include assessment of pulse oximetry accuracy at 60 minutes, the proportion of measurements within ±2 percentage points of SaO₂, changes in peripheral perfusion during 4 hours of follow-up, the local versus systemic perfusion response assessed using finger and earlobe PFI, the response to repeat warming, safety outcomes, and possible treatment-effect modification according to Fitzpatrick skin phototype.

The planned sample size is 240 participants, with 120 participants allocated to each study group.

Studietyp

Interventionell

Inskrivning (Beräknad)

240

Fas

  • Inte tillämpbar

Kontakter och platser

Det här avsnittet innehåller kontaktuppgifter för dem som genomför studien och information om var denna studie genomförs.

Studiekontakt

Studieorter

      • Gothenburg, Sverige
        • Sahlgrenska University Hospital
        • Kontakt:
      • Kungälv, Sverige
        • Kungälvs Sjukhus
      • Skövde, Sverige
        • Skaraborgs Sjukhus
      • Trollhättan, Sverige
        • Norra Älvsborgs Sjukhus

Deltagandekriterier

Forskare letar efter personer som passar en viss beskrivning, så kallade behörighetskriterier. Några exempel på dessa kriterier är en persons allmänna hälsotillstånd eller tidigare behandlingar.

Urvalskriterier

Åldrar som är berättigade till studier

  • Vuxen
  • Äldre vuxen

Tar emot friska volontärer

Nej

Beskrivning

Inclusion Criteria:

  • Age 18 years or older.
  • Admitted to an intensive care unit.
  • Receiving invasive mechanical ventilation via endotracheal tube or tracheostomy.
  • Existing arterial catheter placed for a clinical indication.
  • Objectively verified low peripheral perfusion, defined as finger perfusion index (PFI) <1.0 at screening.
  • Stable baseline pulse oximetry signal permitting calculation of the SpO2-SaO2 difference.
  • Clinical condition considered sufficiently stable to allow study measurements without interfering with ongoing treatment.

Exclusion Criteria:

  • Absence of a stable baseline pulse oximetry signal on all available sensors, preventing calculation of the SpO2-SaO2 difference.
  • Skin injury, burn, infection, or other local skin condition of the hand or forearm that prevents safe application of the warming pad or pulse oximetry sensor.
  • Clinical instability for which the treating physician considers study participation likely to interfere with acute treatment or patient safety.
  • Known hypersensitivity to materials used in the warming pad or sensors.
  • Participation in another ongoing interventional study that could affect the primary outcome.

Studieplan

Det här avsnittet ger detaljer om studieplanen, inklusive hur studien är utformad och vad studien mäter.

Hur är studien utformad?

Designdetaljer

  • Primärt syfte: Stödjande vård
  • Tilldelning: Randomiserad
  • Interventionsmodell: Parallellt uppdrag
  • Maskning: Ingen (Open Label)

Vapen och interventioner

Deltagargrupp / Arm
Intervention / Behandling
Experimentell: Protocolized Local Warming
Participants receive protocolized local warming applied to the dorsum of the hand and distal forearm for 15 minutes, targeting an interface temperature of 41-42°C. Repeat warming is permitted during follow-up if finger perfusion index decreases below 0.5.
Local warming is applied to the dorsum of the hand and distal forearm for 15 minutes using a warming device adjusted to achieve a target interface temperature of 41-42°C. During follow-up, repeat warming is permitted if finger perfusion index decreases below 0.5.
Inget ingripande: Usual Care Without Protocolized Warming
Participants receive usual care without protocolized local warming. Oxygen therapy and all other clinical management are provided according to standard intensive care practice.

Vad mäter studien?

Primära resultatmått

Resultatmått
Åtgärdsbeskrivning
Tidsram
SpO2-SaO2 Bias at 15 Minutes
Tidsram: 15 minutes after initiation of the randomized strategy
Pulse oximetry bias is defined as peripheral oxygen saturation measured by pulse oximetry (SpO2) minus arterial oxygen saturation measured by blood gas analysis (SaO2), expressed in percentage points. The primary analysis will compare SpO2-SaO2 bias between the local warming and control groups at 15 minutes, adjusted for baseline bias and study site.
15 minutes after initiation of the randomized strategy

Sekundära resultatmått

Resultatmått
Åtgärdsbeskrivning
Tidsram
SpO2-SaO2 Bias at 60 Minutes
Tidsram: 60 minutes after initiation of the randomized strategy
Pulse oximetry bias is defined as SpO2 minus SaO2, expressed in percentage points. Bias at 60 minutes will be compared between randomized groups to evaluate durability of the effect of the warming strategy.
60 minutes after initiation of the randomized strategy
Proportion of SpO2 Measurements Within ±2 Percentage Points of SaO2
Tidsram: 15 and 60 minutes after initiation of the randomized strategy
The proportion of participants with an absolute difference between SpO2 and SaO2 of 2 percentage points or less will be determined at 15 and 60 minutes and compared between randomized groups.
15 and 60 minutes after initiation of the randomized strategy
Change in Finger Perfusion Index
Tidsram: Baseline and 15, 60, 120, and 240 minutes
Finger perfusion index (PFI) will be measured serially to assess the peripheral perfusion response to the randomized strategy and its durability during 4 hours of follow-up.
Baseline and 15, 60, 120, and 240 minutes
Difference Between Finger and Earlobe Perfusion Index Response
Tidsram: Baseline, 15 minutes, and 60 minutes
Changes in perfusion index measured at the finger and earlobe will be compared to assess whether the perfusion response to local warming is predominantly local rather than systemic.
Baseline, 15 minutes, and 60 minutes
Perfusion Index Response to Repeat Local Warming
Tidsram: Up to 240 minutes after randomization
Among participants in the warming group who undergo repeat warming because finger PFI decreases below 0.5 during follow-up, the change in finger PFI following repeat warming will be assessed to evaluate repeatability of the perfusion response.
Up to 240 minutes after randomization
Warming-Related Adverse Events
Tidsram: From initiation of the randomized strategy through 240 minutes
Number of participants experiencing adverse events considered related to local warming, including skin injury, erythema requiring discontinuation of warming, or other prespecified adverse reactions during the study period.
From initiation of the randomized strategy through 240 minutes

Andra resultatmått

Resultatmått
Åtgärdsbeskrivning
Tidsram
Treatment Effect on SpO2-SaO2 Bias According to Fitzpatrick Skin Phototype
Tidsram: 15 minutes after initiation of the randomized strategy
Prespecified analysis of treatment-effect modification according to Fitzpatrick skin phototype. The interaction between randomized treatment group and Fitzpatrick skin phototype will be evaluated for the primary outcome of SpO2-SaO2 bias at 15 minutes.
15 minutes after initiation of the randomized strategy

Samarbetspartners och utredare

Det är här du hittar personer och organisationer som är involverade i denna studie.

Studieavstämningsdatum

Dessa datum spårar framstegen för inlämningar av studieposter och sammanfattande resultat till ClinicalTrials.gov. Studieposter och rapporterade resultat granskas av National Library of Medicine (NLM) för att säkerställa att de uppfyller specifika kvalitetskontrollstandarder innan de publiceras på den offentliga webbplatsen.

Studera stora datum

Studiestart (Beräknad)

1 oktober 2026

Primärt slutförande (Beräknad)

1 oktober 2028

Avslutad studie (Beräknad)

1 december 2028

Studieregistreringsdatum

Först inskickad

24 augusti 2026

Först inskickad som uppfyllde QC-kriterierna

24 augusti 2026

Första postat (Faktisk)

28 augusti 2026

Uppdateringar av studier

Senaste uppdatering publicerad (Faktisk)

28 augusti 2026

Senaste inskickade uppdateringen som uppfyllde QC-kriterierna

24 augusti 2026

Senast verifierad

1 augusti 2026

Mer information

Termer relaterade till denna studie

Plan för individuella deltagardata (IPD)

Planerar du att dela individuella deltagardata (IPD)?

OBESLUTSAM

IPD-planbeskrivning

The feasibility and conditions for sharing de-identified individual participant data have not yet been determined. Any future data sharing will be subject to applicable ethical approvals, data protection regulations, institutional policies, and appropriate data-sharing agreements.

Läkemedels- och apparatinformation, studiedokument

Studerar en amerikansk FDA-reglerad läkemedelsprodukt

Nej

Studerar en amerikansk FDA-reglerad produktprodukt

Nej

Denna information hämtades direkt från webbplatsen clinicaltrials.gov utan några ändringar. Om du har några önskemål om att ändra, ta bort eller uppdatera dina studieuppgifter, vänligen kontakta register@clinicaltrials.gov. Så snart en ändring har implementerats på clinicaltrials.gov, kommer denna att uppdateras automatiskt även på vår webbplats .

Prenumerera