The Novel Approach of Minimally Invasive Parathyroid Surgery Requires Precise Identification and Localization of the Lesion Prior to Exploration

2010年10月21日 更新者:Rambam Health Care Campus

A Novel Approach to Ultrafast Parathyroid SPECT Imaging Using a Solid State CZT SPECT Camera

Purpose of this study is to compare the image quality and diagnostic accuracy obtained with ultrafast solid state short SPECT in comparison with the routine SPECT protocol.

研究概览

详细说明

Single-tracer, dual-phase Tc-MIBI parathyroid scintigraphy is based on the differential washout rate of the tracer (MIBI) from the thyroid and the parathyroid tissue. A distinct focus of increased MIBI uptake relative to the thyroid gland, either on the early or late image or on both, or a focal uptake in the mediastinum, is considered positive for abnormal parathyroid tissue. Tc99m-MIBI planar scintigraphy was found to play a major role in the preoperative localization of a parathyroid adenoma (PTA), with a sensitivity ranging from 85% to 95% and specificity of up to 99%. Subsequently, the use of MIBI- Single photon emission computed tomography (SPECT) significantly improved the sensitivity of the test and improved the accuracy of lesion localization.

A limitation of adding the SPECT component is related to its relatively long duration. The duration of a MIBI-SPECT acquisition of neck and the mediastinal area may take up to 15-20 minutes using a standard nuclear medicine camera. Long acquisition time may lead to patient discomfort and movement resulting in image degradation, artifacts and may lead to overall decreased diagnostic accuracy.

A reduced SPECT acquisition time without image quality degradation may decrease patient discomfort and increase clinical throughput. An ultrafast solid state CZT camera (GE Healthcare Discovery 570C) is currently used for routine cardiac SPECT imaging achieving high quality cardiac studies for a significantly shorter acquisition time. Present study evaluates the potential use of the ultrafast camera in patients with a clinically suspected PTA who perform Tc-MIBI imaging.

研究类型

观察性的

注册 (预期的)

50

联系人和位置

本节提供了进行研究的人员的详细联系信息,以及有关进行该研究的地点的信息。

学习地点

      • Haifa、以色列、36029
        • Rambam Healthcare Campus

参与标准

研究人员寻找符合特定描述的人,称为资格标准。这些标准的一些例子是一个人的一般健康状况或先前的治疗。

资格标准

适合学习的年龄

18年 至 75年 (成人、年长者)

接受健康志愿者

不

有资格学习的性别

全部

取样方法

非概率样本

研究人群

Patients referred for the parathyroid scan.

描述

Inclusion Criteria:

1) The subject is 18 years old or older. (2) The subject is clinically suspected or known to have parathyroid adenoma and is scheduled to have a MIBI study as part of his/her standard clinical evaluation.

(3) The subject is able and willing to comply with the additional procedure (ultrafast MIBI SPECT) and a signed and dated informed consent is obtained before any procedure for study purposes is performed.

Exclusion Criteria:

  1. Pregnancy.
  2. Psychosis or any other condition, which, in the investigators opinion would prevent adherence to the study protocol.

学习计划

本节提供研究计划的详细信息,包括研究的设计方式和研究的衡量标准。

研究是如何设计的?

设计细节

合作者和调查者

在这里您可以找到参与这项研究的人员和组织。

出版物和有用的链接

负责输入研究信息的人员自愿提供这些出版物。这些可能与研究有关。

研究记录日期

这些日期跟踪向 ClinicalTrials.gov 提交研究记录和摘要结果的进度。研究记录和报告的结果由国家医学图书馆 (NLM) 审查,以确保它们在发布到公共网站之前符合特定的质量控制标准。

研究主要日期

学习开始

2011年1月1日

研究注册日期

首次提交

2010年10月21日

首先提交符合 QC 标准的

2010年10月21日

首次发布 (估计)

2010年10月22日

研究记录更新

最后更新发布 (估计)

2010年10月22日

上次提交的符合 QC 标准的更新

2010年10月21日

最后验证

2010年10月1日

更多信息

与本研究相关的术语

此信息直接从 clinicaltrials.gov 网站检索,没有任何更改。如果您有任何更改、删除或更新研究详细信息的请求,请联系 register@clinicaltrials.gov. clinicaltrials.gov 上实施更改,我们的网站上也会自动更新.