Optimal Head Rotation and External Landmark for Internal Jugular Vein Cannulation After Placement of Proseal Laryngeal Mask Airway
Recently, laryngeal mask airway (LMA) placements are frequently performed for general anesthesia. The investigators occasionally encounter a clinical situation to perform internal jugular vein (IJV) cannulation after LMA insertion, especially for difficult airway in subjects undergoing major surgery. However, anatomic relations of IJV and common carotid artery (CCA) in patient with LMA placement have been reported to be different from those in patients with endotracheal tube. The degree of overlapping of the right IJV and CCA after LMA placement was greater than before LMA placement. Furthermore, there are many cases of complete overlapping right IJV and CCA after LMA placement. Therefore, the risk of puncturing CCA increases when the investigators try to cannulate IJV after LMA placement. Furthermore, the central landmark commonly used for IJV cannulation was proved to show low success rate after LMA placement in previous report.
The investigators carefully examined the anatomic relations of IJV and CCA after LMA insertion with ultrasonography, and found that the degree of overlapping is different according to the degree of head rotation. The investigators postulated that if the degree of overlapping is different according to the degree of head rotation after LMA insertion, the investigators can find the angle of head rotation for least overlapping and reduce the risk of CCA puncture. Therefore, the investigators tried (1) to find the optimal head rotation angle appropriate for puncturing IJV after LMA placement, and (2) to find suitable landmark adequate for IJV cannulation after LMA placement.
研究概览
详细说明
研究类型
注册 (实际的)
联系人和位置
学习地点
-
-
-
Seoul、大韩民国、135-710
- Samsung Medical Center
-
-
参与标准
资格标准
适合学习的年龄
接受健康志愿者
有资格学习的性别
取样方法
研究人群
描述
Inclusion Criteria:
- patients undergoing general anesthesia with laryngeal mask airway insertion
Exclusion Criteria:
- patients undergoing emergency surgery
- patients with anatomical problem of airway
- anticipated difficult airway
- patients with hemodynamic unstability
- patients with severe cardiopulmonary disease
学习计划
研究是如何设计的?
设计细节
队列和干预
团体/队列 |
干预/治疗 |
|---|---|
|
LMA group
patients undergoing general anesthesia with LMA insertion
|
Repeated ultrasonographic examination according to the degree of head rotation (examination of overlap index of internal jugular vein and common carotid artery, and accuracy of external landmark of jugular cannulation)
|
|
E-tube group
patients undergoing general anesthesia with e-tube
|
Repeated ultrasonographic examination according to the degree of head rotation (examination of overlap index of internal jugular vein and common carotid artery, and accuracy of external landmark of jugular cannulation)
|
研究衡量的是什么?
主要结果指标
结果测量 |
措施说明 |
大体时间 |
|---|---|---|
|
overlap index
大体时间:at 5 min after anesthesia induction
|
The overlap index was derived from the ratio of the overlapping length of the IJV to the horizontal diameter of the CCA measured on the ultrasonographic image.
The formula of calculation is as follows: overlap index = [overlap length (mm)/ CCA diameter (mm)] X 100(%), the measurements were repeated according to the degree of head rotation (neutral, 15 degree, 30 degree, 45 degree)
|
at 5 min after anesthesia induction
|
次要结果测量
结果测量 |
措施说明 |
大体时间 |
|---|---|---|
|
The success of simulated internal jugular vein puncture (central landmark)
大体时间:at 5 min after anesthesia induction
|
The success of internal jugular vein puncture guided by the central landmark simulated on the ultrasonographic images, the measurements were repeated according to the degree of head rotation (neutral, 15 degree, 30 degree, 45 degree)
|
at 5 min after anesthesia induction
|
|
The success of simulated internal jugular vein puncture (external jugular vein landmark)
大体时间:at 5 min after anesthesia induction
|
The success of internal jugular vein puncture as guided by 1.5 cm or 2.5 cm medial to the external jugular vein simulated on the ultrasonographic images, the measurements were repeated according to the degree of head rotation (neutral, 15 degrees, 30 degrees, 45 degrees)
|
at 5 min after anesthesia induction
|
合作者和调查者
研究记录日期
研究主要日期
学习开始
初级完成 (实际的)
研究完成 (实际的)
研究注册日期
首次提交
首先提交符合 QC 标准的
首次发布 (估计)
研究记录更新
最后更新发布 (估计)
上次提交的符合 QC 标准的更新
最后验证
更多信息
此信息直接从 clinicaltrials.gov 网站检索,没有任何更改。如果您有任何更改、删除或更新研究详细信息的请求,请联系 register@clinicaltrials.gov. clinicaltrials.gov 上实施更改,我们的网站上也会自动更新.