Optimal Head Rotation and External Landmark for Internal Jugular Vein Cannulation After Placement of Proseal Laryngeal Mask Airway
Recently, laryngeal mask airway (LMA) placements are frequently performed for general anesthesia. The investigators occasionally encounter a clinical situation to perform internal jugular vein (IJV) cannulation after LMA insertion, especially for difficult airway in subjects undergoing major surgery. However, anatomic relations of IJV and common carotid artery (CCA) in patient with LMA placement have been reported to be different from those in patients with endotracheal tube. The degree of overlapping of the right IJV and CCA after LMA placement was greater than before LMA placement. Furthermore, there are many cases of complete overlapping right IJV and CCA after LMA placement. Therefore, the risk of puncturing CCA increases when the investigators try to cannulate IJV after LMA placement. Furthermore, the central landmark commonly used for IJV cannulation was proved to show low success rate after LMA placement in previous report.
The investigators carefully examined the anatomic relations of IJV and CCA after LMA insertion with ultrasonography, and found that the degree of overlapping is different according to the degree of head rotation. The investigators postulated that if the degree of overlapping is different according to the degree of head rotation after LMA insertion, the investigators can find the angle of head rotation for least overlapping and reduce the risk of CCA puncture. Therefore, the investigators tried (1) to find the optimal head rotation angle appropriate for puncturing IJV after LMA placement, and (2) to find suitable landmark adequate for IJV cannulation after LMA placement.
Studieöversikt
Status
Intervention / Behandling
Detaljerad beskrivning
Studietyp
Inskrivning (Faktisk)
Kontakter och platser
Studieorter
-
-
-
Seoul, Korea, Republiken av, 135-710
- Samsung Medical Center
-
-
Deltagandekriterier
Urvalskriterier
Åldrar som är berättigade till studier
Tar emot friska volontärer
Kön som är behöriga för studier
Testmetod
Studera befolkning
Beskrivning
Inclusion Criteria:
- patients undergoing general anesthesia with laryngeal mask airway insertion
Exclusion Criteria:
- patients undergoing emergency surgery
- patients with anatomical problem of airway
- anticipated difficult airway
- patients with hemodynamic unstability
- patients with severe cardiopulmonary disease
Studieplan
Hur är studien utformad?
Designdetaljer
Kohorter och interventioner
Grupp / Kohort |
Intervention / Behandling |
|---|---|
|
LMA group
patients undergoing general anesthesia with LMA insertion
|
Repeated ultrasonographic examination according to the degree of head rotation (examination of overlap index of internal jugular vein and common carotid artery, and accuracy of external landmark of jugular cannulation)
|
|
E-tube group
patients undergoing general anesthesia with e-tube
|
Repeated ultrasonographic examination according to the degree of head rotation (examination of overlap index of internal jugular vein and common carotid artery, and accuracy of external landmark of jugular cannulation)
|
Vad mäter studien?
Primära resultatmått
Resultatmått |
Åtgärdsbeskrivning |
Tidsram |
|---|---|---|
|
overlap index
Tidsram: at 5 min after anesthesia induction
|
The overlap index was derived from the ratio of the overlapping length of the IJV to the horizontal diameter of the CCA measured on the ultrasonographic image.
The formula of calculation is as follows: overlap index = [overlap length (mm)/ CCA diameter (mm)] X 100(%), the measurements were repeated according to the degree of head rotation (neutral, 15 degree, 30 degree, 45 degree)
|
at 5 min after anesthesia induction
|
Sekundära resultatmått
Resultatmått |
Åtgärdsbeskrivning |
Tidsram |
|---|---|---|
|
The success of simulated internal jugular vein puncture (central landmark)
Tidsram: at 5 min after anesthesia induction
|
The success of internal jugular vein puncture guided by the central landmark simulated on the ultrasonographic images, the measurements were repeated according to the degree of head rotation (neutral, 15 degree, 30 degree, 45 degree)
|
at 5 min after anesthesia induction
|
|
The success of simulated internal jugular vein puncture (external jugular vein landmark)
Tidsram: at 5 min after anesthesia induction
|
The success of internal jugular vein puncture as guided by 1.5 cm or 2.5 cm medial to the external jugular vein simulated on the ultrasonographic images, the measurements were repeated according to the degree of head rotation (neutral, 15 degrees, 30 degrees, 45 degrees)
|
at 5 min after anesthesia induction
|
Samarbetspartners och utredare
Sponsor
Studieavstämningsdatum
Studera stora datum
Studiestart
Primärt slutförande (Faktisk)
Avslutad studie (Faktisk)
Studieregistreringsdatum
Först inskickad
Först inskickad som uppfyllde QC-kriterierna
Första postat (Uppskatta)
Uppdateringar av studier
Senaste uppdatering publicerad (Uppskatta)
Senaste inskickade uppdateringen som uppfyllde QC-kriterierna
Senast verifierad
Mer information
Termer relaterade till denna studie
Nyckelord
Andra studie-ID-nummer
- 2011-04-024
Denna information hämtades direkt från webbplatsen clinicaltrials.gov utan några ändringar. Om du har några önskemål om att ändra, ta bort eller uppdatera dina studieuppgifter, vänligen kontakta register@clinicaltrials.gov. Så snart en ändring har implementerats på clinicaltrials.gov, kommer denna att uppdateras automatiskt även på vår webbplats .