Esta página se tradujo automáticamente y no se garantiza la precisión de la traducción. por favor refiérase a versión inglesa para un texto fuente.

Optimal Head Rotation and External Landmark for Internal Jugular Vein Cannulation After Placement of Proseal Laryngeal Mask Airway

24 de diciembre de 2013 actualizado por: Gwak Mi Sook, Samsung Medical Center

Recently, laryngeal mask airway (LMA) placements are frequently performed for general anesthesia. The investigators occasionally encounter a clinical situation to perform internal jugular vein (IJV) cannulation after LMA insertion, especially for difficult airway in subjects undergoing major surgery. However, anatomic relations of IJV and common carotid artery (CCA) in patient with LMA placement have been reported to be different from those in patients with endotracheal tube. The degree of overlapping of the right IJV and CCA after LMA placement was greater than before LMA placement. Furthermore, there are many cases of complete overlapping right IJV and CCA after LMA placement. Therefore, the risk of puncturing CCA increases when the investigators try to cannulate IJV after LMA placement. Furthermore, the central landmark commonly used for IJV cannulation was proved to show low success rate after LMA placement in previous report.

The investigators carefully examined the anatomic relations of IJV and CCA after LMA insertion with ultrasonography, and found that the degree of overlapping is different according to the degree of head rotation. The investigators postulated that if the degree of overlapping is different according to the degree of head rotation after LMA insertion, the investigators can find the angle of head rotation for least overlapping and reduce the risk of CCA puncture. Therefore, the investigators tried (1) to find the optimal head rotation angle appropriate for puncturing IJV after LMA placement, and (2) to find suitable landmark adequate for IJV cannulation after LMA placement.

Descripción general del estudio

Estado

Terminado

Intervención / Tratamiento

Descripción detallada

Recently, laryngeal mask airway (LMA) placements are frequently performed for general anesthesia. The investigators occasionally encounter a clinical situation to perform internal jugular vein (IJV) cannulation after LMA insertion, especially for difficult airway in subjects undergoing major surgery. However, anatomic relations of IJV and common carotid artery (CCA) in patient with LMA placement have been reported to be different from those in patients with endotracheal tube. The degree of overlapping of the right IJV and CCA after LMA placement was greater than before LMA placement. Furthermore, there are many cases of complete overlapping right IJV and CCA after LMA placement. Therefore, the risk of puncturing CCA increases when the investigators try to cannulate IJV after LMA placement. Furthermore, the central landmark commonly used for IJV cannulation was proved to show low success rate after LMA placement in previous report. Previous study recommended the lower puncture point near that area where the clavicular head of the sternocleidomastoid muscle attaches to the clavicle, because CCA was not observed in the vicinity of the IJV after LMA insertion. Even though they performed test puncture at the lower puncture point in 20 patients and found no complications, the lower puncture point is not the usual site for IJV cannulation for most anesthesiologists. It is known that increased head rotation is associated with high probability of CCA contact. The investigators carefully examined the anatomic relations of IJV and CCA after LMA insertion with ultrasonography, and found that the degree of overlapping is different according to the degree of head rotation. The investigators postulated that if the degree of overlapping is different according to the degree of head rotation after LMA insertion, the investigators can find the angle of head rotation for least overlapping and reduce the risk of CCA puncture. Therefore, the investigators tried (1) to find the optimal head rotation angle appropriate for puncturing IJV after LMA placement, and (2) to find suitable landmark adequate for IJV cannulation after LMA placement.

Tipo de estudio

De observación

Inscripción (Actual)

100

Contactos y Ubicaciones

Esta sección proporciona los datos de contacto de quienes realizan el estudio e información sobre dónde se lleva a cabo este estudio.

Ubicaciones de estudio

Criterios de participación

Los investigadores buscan personas que se ajusten a una determinada descripción, denominada criterio de elegibilidad. Algunos ejemplos de estos criterios son el estado de salud general de una persona o tratamientos previos.

Criterio de elegibilidad

Edades elegibles para estudiar

20 años a 70 años (Adulto, Adulto Mayor)

Acepta Voluntarios Saludables

No

Géneros elegibles para el estudio

Todos

Método de muestreo

Muestra no probabilística

Población de estudio

patients undergoing general anesthesia with laryngeal mask airway insertion

Descripción

Inclusion Criteria:

  • patients undergoing general anesthesia with laryngeal mask airway insertion

Exclusion Criteria:

  • patients undergoing emergency surgery
  • patients with anatomical problem of airway
  • anticipated difficult airway
  • patients with hemodynamic unstability
  • patients with severe cardiopulmonary disease

Plan de estudios

Esta sección proporciona detalles del plan de estudio, incluido cómo está diseñado el estudio y qué mide el estudio.

¿Cómo está diseñado el estudio?

Detalles de diseño

Cohortes e Intervenciones

Grupo / Cohorte
Intervención / Tratamiento
LMA group
patients undergoing general anesthesia with LMA insertion
Repeated ultrasonographic examination according to the degree of head rotation (examination of overlap index of internal jugular vein and common carotid artery, and accuracy of external landmark of jugular cannulation)
E-tube group
patients undergoing general anesthesia with e-tube
Repeated ultrasonographic examination according to the degree of head rotation (examination of overlap index of internal jugular vein and common carotid artery, and accuracy of external landmark of jugular cannulation)

¿Qué mide el estudio?

Medidas de resultado primarias

Medida de resultado
Medida Descripción
Periodo de tiempo
overlap index
Periodo de tiempo: at 5 min after anesthesia induction
The overlap index was derived from the ratio of the overlapping length of the IJV to the horizontal diameter of the CCA measured on the ultrasonographic image. The formula of calculation is as follows: overlap index = [overlap length (mm)/ CCA diameter (mm)] X 100(%), the measurements were repeated according to the degree of head rotation (neutral, 15 degree, 30 degree, 45 degree)
at 5 min after anesthesia induction

Medidas de resultado secundarias

Medida de resultado
Medida Descripción
Periodo de tiempo
The success of simulated internal jugular vein puncture (central landmark)
Periodo de tiempo: at 5 min after anesthesia induction
The success of internal jugular vein puncture guided by the central landmark simulated on the ultrasonographic images, the measurements were repeated according to the degree of head rotation (neutral, 15 degree, 30 degree, 45 degree)
at 5 min after anesthesia induction
The success of simulated internal jugular vein puncture (external jugular vein landmark)
Periodo de tiempo: at 5 min after anesthesia induction
The success of internal jugular vein puncture as guided by 1.5 cm or 2.5 cm medial to the external jugular vein simulated on the ultrasonographic images, the measurements were repeated according to the degree of head rotation (neutral, 15 degrees, 30 degrees, 45 degrees)
at 5 min after anesthesia induction

Colaboradores e Investigadores

Aquí es donde encontrará personas y organizaciones involucradas en este estudio.

Patrocinador

Fechas de registro del estudio

Estas fechas rastrean el progreso del registro del estudio y los envíos de resultados resumidos a ClinicalTrials.gov. Los registros del estudio y los resultados informados son revisados ​​por la Biblioteca Nacional de Medicina (NLM) para asegurarse de que cumplan con los estándares de control de calidad específicos antes de publicarlos en el sitio web público.

Fechas importantes del estudio

Inicio del estudio

1 de julio de 2011

Finalización primaria (Actual)

1 de diciembre de 2012

Finalización del estudio (Actual)

1 de diciembre de 2012

Fechas de registro del estudio

Enviado por primera vez

21 de julio de 2011

Primero enviado que cumplió con los criterios de control de calidad

31 de julio de 2011

Publicado por primera vez (Estimar)

2 de agosto de 2011

Actualizaciones de registros de estudio

Última actualización publicada (Estimar)

25 de diciembre de 2013

Última actualización enviada que cumplió con los criterios de control de calidad

24 de diciembre de 2013

Última verificación

1 de diciembre de 2013

Más información

Términos relacionados con este estudio

Otros números de identificación del estudio

  • 2011-04-024

Esta información se obtuvo directamente del sitio web clinicaltrials.gov sin cambios. Si tiene alguna solicitud para cambiar, eliminar o actualizar los detalles de su estudio, comuníquese con register@clinicaltrials.gov. Tan pronto como se implemente un cambio en clinicaltrials.gov, también se actualizará automáticamente en nuestro sitio web. .