REPARA Study: REgistry of PAtients With bioResorbable Device in Daily Clinical prActice (REPARA)

Registry of Patients With Bioresorbable Device in Daily Clinical Practice. REPARA Study

A multicentre, observational, prospective device registry, with no control group, designed to evaluate the efficacy and safety of the bioresorbable coronary device, used according to the indications of use, in daily clinical practice in a consecutive number of patients undergoing PCI in de novo coronary artery lesions. A total of 1,500 patients are planned to be included in the registry.

研究概览

详细说明

The patients will be included consecutively at each site for one year. They will be individuals from both sexes, requiring endovascular intervention and meeting the authorised criteria for the indications of use of the device to be used and where dual anti-platelet therapy (DAPT) with aspirin and thienopyridines is considered.

STUDY OBJECTIVES To evaluate the MACE rate after implantation of the bioresorbable coronary device in patients with de novo coronary artery lesions, where a follow-up of 12 months will be performed.

Primary objective:

MACE rate at 12 months of follow-up:

Cardiac death Myocardial infarction TLR driven by ischaemia of the lesion treated or of the region of 5 mm proximally or distally to the site of implantation of the device (ID-TLR).

Secondary objectives:

  • Angina
  • Death due to any cause.
  • Myocardial infarction of any type (MI: QMI, NQMI, TV, NTV)
  • All TLR driven or not by ischaemia
  • All TVR driven or not by ischaemia.
  • All coronary revascularisations performed (PCI vs CABG)
  • Device thrombosis (acute, sub-acute, late) and evidence (definitive, probable, possible).
  • Immediate success of the device.
  • Immediate success of the procedure.
  • Rate of patients with DAPT at < 1 month, 1-3 months, 3-6 months, and 6-12 months and relationship with the occurrence of events
  • Composite endpoints:

Cardiac death, TV-MI and ID-TLR: (Target Lesion Failure (TLF)) Cardiac death, any myocardial infarction (MI) and ID-TVR: (Target Vessel Failure (TVF))

  • Rate of overlapping devices: characteristics and relationship with occurrence of events
  • Collection of imaging data of the cases where, according to the judgement of the investigator, intravascular imaging tests have been performed (IVUS, OCT).

研究类型

观察性的

注册 (实际的)

2440

联系人和位置

本节提供了进行研究的人员的详细联系信息,以及有关进行该研究的地点的信息。

学习地点

      • Madrid、西班牙、28041
        • Hospital 12 de Octubre

参与标准

研究人员寻找符合特定描述的人,称为资格标准。这些标准的一些例子是一个人的一般健康状况或先前的治疗。

资格标准

适合学习的年龄

18年 及以上 (成人、年长者)

接受健康志愿者

不

有资格学习的性别

全部

取样方法

非概率样本

研究人群

Patients with native coronary artery de novo lesions with indication for revascularization with a coronary device

描述

Inclusion Criteria:

  • Patient must be at least 18 years of age at the time of signing the Informed Consent Form
  • Patient is to be treated for de novo coronary lesions in a native coronary artery and amenable to receive a bioresorbable device
  • The length of the treated lesion should be inferior to the nominal length of the device (12 mm, 18 mm, 28 mm) with a reference vessel diameter > 2 mm y < 3,8 mm.
  • The patient will not have any relative contraindication for double antiplatelet therapy, with aspirin indefinitely and with a thienopyridine for at least 6 months

Exclusion Criteria:

  • Cardiogenic shock
  • Left main disease
  • Aortocoronary graft
  • Intrastent restenosis
  • Potentially child-bearing women with no contraceptive methods
  • Pregnant or breast-feeding women

学习计划

本节提供研究计划的详细信息,包括研究的设计方式和研究的衡量标准。

研究是如何设计的?

设计细节

  • 观测模型:队列
  • 时间观点:预期

队列和干预

团体/队列
BVS patients
Use of bioresorbable coronary device, according to the indications of use, in daily clinical practice, in patients undergoing PCI in de novo coronary artery lesions.

研究衡量的是什么?

主要结果指标

结果测量
大体时间
MACE rate (major adverse cardiac events) at 12 months of follow-up: Cardiac death; Myocardial infarction; Target lesion revascularisation (TLR) ischemia-driven: Cardiac Death/All MI/ID-TLR
大体时间:Clinical follow-up at 12 months
Clinical follow-up at 12 months

次要结果测量

结果测量
大体时间
Immediate success of the device/procedure
大体时间:1 day
1 day
心脏死亡
大体时间:12个月
12个月
心肌梗塞
大体时间:12个月
12个月
Scaffold/Stent Thrombosis: Timing and Evidence
大体时间:12 months
12 months
Target lesion/vessel revascularization (TLR/TVR)
大体时间:12 months
12 months
Angina Events
大体时间:12 months
12 months
Rate of patients with DAPT at 12 months
大体时间:12 months
12 months
Rate of overlapping devices and characteristics
大体时间:12 months
12 months

合作者和调查者

在这里您可以找到参与这项研究的人员和组织。

调查人员

  • 首席研究员:Felipe Hernandez, MD、Seccion Hemodinamica y Cardiologia Intervencionista

研究记录日期

这些日期跟踪向 ClinicalTrials.gov 提交研究记录和摘要结果的进度。研究记录和报告的结果由国家医学图书馆 (NLM) 审查,以确保它们在发布到公共网站之前符合特定的质量控制标准。

研究主要日期

学习开始

2014年1月1日

初级完成 (实际的)

2015年9月1日

研究完成 (预期的)

2016年10月1日

研究注册日期

首次提交

2014年9月23日

首先提交符合 QC 标准的

2014年9月30日

首次发布 (估计)

2014年10月3日

研究记录更新

最后更新发布 (估计)

2016年7月18日

上次提交的符合 QC 标准的更新

2016年7月15日

最后验证

2016年7月1日

更多信息

与本研究相关的术语

其他研究编号

  • COR-BVS-2013-01