The AID Study: Artificial Intelligence for Colorectal Adenoma Detection (AID)
Colonoscopy is clinically used as the gold standard for detection of colon cancer (CRC) and removal of adenomatous polyps. Despite the success of colonoscopy in reducing cancer-related deaths, there exists a disappointing level of adenomas missed at colonoscopy. "Back-to-back" colonoscopies have indicated significant miss rates of 27% for small adenomas (< 5 mm) and 6% for adenomas of more than 10 mm in diameter. Studies performing both CT colonography and colonoscopy estimate that the colonoscopy miss rate for polyps over 10 mm in size may be as high as 12%. The clinical importance of missed lesions should be emphasized because these lesions may ultimately progress to CRC8.
Limitations in human visual perception and other human biases such as fatigue, distraction, level of alertness during examination increases such recognition errors and way of mitigating them may be the key to improve polyp detection and further reduction in mortality from CRC. In the past years, a number of CAD systems for detection of polyps from endoscopy images have been described. However, the benefits of traditional CAD technologies in colonoscopy appear to be contradictory, therefore they should be improved to be ultimately considered useful. Recent advances in artificial intelligence (AI), deep learning (DL), and computer vision have shown potential to assist polyp detection during colonoscopy.
研究概览
研究类型
注册 (实际的)
联系人和位置
学习地点
-
-
Milano
-
Rozzano、Milano、意大利、20089
- Endoscopy Unit, Humanitas Research Hospital
-
-
参与标准
资格标准
适合学习的年龄
接受健康志愿者
有资格学习的性别
取样方法
研究人群
描述
Inclusion Criteria:
All 40-80 years-old subjects undergoing a colonoscopy.
Exclusion Criteria:
- subjects with personal history of CRC, or IBD.
- patients with inadequate bowel preparation (defined as Boston Bowel Preparation Scale > 2 in any colonic segment).
- patients with previous colonic resection.
- patients on antithrombotic therapy, precluding polyp resection.
- patients who were not able or refused to give informed written consent.
学习计划
研究是如何设计的?
设计细节
队列和干预
团体/队列 |
干预/治疗 |
|---|---|
|
控制
白光结肠镜检查
|
|
|
AI
Artificial Intelligence colonoscopy
|
Artificial intellignece colonoscopy
|
研究衡量的是什么?
主要结果指标
结果测量 |
措施说明 |
大体时间 |
|---|---|---|
|
Additional diagnostic yield obtained by AI-aided colonoscopy to the yield obtained by the Standard (high-definition) colonoscopy
大体时间:3 Months
|
To compare the additional diagnostic yield obtained by AI-aided colonoscopy to the yield obtained by the Standard (high-definition) colonoscopy
|
3 Months
|
合作者和调查者
调查人员
- 首席研究员:Alessandro Repici, MD、HUMANITAS Research Hospital
研究记录日期
研究主要日期
学习开始 (实际的)
初级完成 (实际的)
研究完成 (实际的)
研究注册日期
首次提交
首先提交符合 QC 标准的
首次发布 (实际的)
研究记录更新
最后更新发布 (实际的)
上次提交的符合 QC 标准的更新
最后验证
更多信息