此页面是自动翻译的,不保证翻译的准确性。请参阅 英文版 对于源文本。

Impact of Pre-cooling in Adolescent Tennis Athletes

2019年12月12日 更新者:Petros Dinas

Impact of Pre-cooling in Adolescent Athletes While Playing Tennis in Hot Conditions

Many tennis tournaments are played outdoors in hot and humid conditions, which poses a significant challenge particularly for children athletes. The purpose of this investigation is to examine if a precooling method can reduce thermal strain and consequently improve the performance of adolescent tennis athletes while exercising in hot conditions.

研究概览

详细说明

Matches were conducted on hard-court surfaces separated by 24h (n=4 pairs) or 144h (n=1pair) between 9am and 6pm and were played in winning two sets. Participants were paired according to their level of play and competed against the same component at the same time of the day in both matches.

Three hours before the start of their scheduled match, each player ingested a telemetric pill in order to estimate the visceral temperature. Upon arrival, all participants provided a urine sample for assessment of urine specific gravity as an indicator of their hydration status and they emptied their bladders before were weighed. They were weighed twice, at baseline and at the end of the match with a precision weight scale (Kern DE 150K2D, KERN & SOHN GmbH, Balingen, Germany). During the match the participants consumed water and any other sport drink and food ad libitum. The total weight of the players' food and fluids that was consumed was measured using a precision weight scale. If participants wished to urinate during the match, they were asked to use a urine cup and their urine was weighed.

One hour before the match, the precooling group was wearing a Cooling Cap (WElkins Sideline Cooling System, SCS) for 45 minutes. On removal from a -20oC freezer, the cap surface was 10.7±2.5oC. After 45 minutes, participants removed the cap and they performed a 5 minutes standardized warm-up (running around the court and running exercises from baseline to net and back to baseline) and 10 min tennis specific warm up (rallies and serves) on court. Each participant, before the warm-up, was outfitted with a heart rate chest strap and iBUTTON sensors at four sites of the body (chest, upper arm, thigh and calf).

The scoring and timing characteristics of the matches complied with 2016 ITF rules. Three new balls were used for each match with the players retrieving balls between points. Matches were filmed from one end of the court, using a digital video camera (Sony DCR-VX2000E PAL, Japan). Participants were performed on perceptual measurements at baseline, after each set, and at the end of the match.

Thermoregulatory, cardiovascular and perceptual responses were recorded with standardized techniques: 1) visceral temperature using telemetric pill (BodyCap, Caen, France) was continuously recorded throughout the match; 2) skin temperature using iBUTTON sensors (type DS1921 H, Maxim/Dallas Semiconductor Corp., USA) on chest, upper arm, thigh and calf was recorded continuously; 3) heart rate (HR) variability data were sampled through short-range telemetry at 1,000 Hz with a Polar RS800CX (Polar Electro , Kempele, Finland). The heart rate monitor signal will be transferred to the Polar Precision Performance Software (release 3.00; Polar Electro Oy); 4) thermal comfort (scale 1-5), thermal sensation (scale 1-10) and rating of perceived exertion using standardized questionnaires were recorded at baseline, after each set, and at the end of the match.

Hydration status was recorded with urine specific gravity. All the collected urine samples will be analyzed using a refractrometer (Atago, Tokyo, Japan) for the determination of urine specific gravity. Euhydration will be defined as urine specific gravity <1.02 according to internationally accepted standards.

A digital video camera (Sony DCR-VX2000E PAL, Japan) was used to record the match - play characteristics. The footage was used to conduct the retrospective notational analysis. The quantitative performance indices that assessed had been: games and points won in each set and normalized to the number of games and points that record in each set respectively. Also unforced errors, first and second serve accuracy, aces, shots per rally and direction changes in each point calculated. Point's duration, between point-duration as well the effective point time calculated. The effective point time starting with the ball toss of the serve and ending when the ball passed the player or bounced twice on court. In case of double fault, starting time recorded from the beginning of the second serve.

Environmental data including air temperature, relative humidity, and wind speed were measured continuously using a portable weather station (Kestrel 5500FW Fire Weather Meter Pro, USA). The weather station was placed 1 meter above the ground according to the manufacturer's guidelines.

研究类型

介入性

注册 (实际的)

8

阶段

  • 不适用

联系人和位置

本节提供了进行研究的人员的详细联系信息,以及有关进行该研究的地点的信息。

学习地点

    • Thessaly
      • Tríkala、Thessaly、希腊、42100
        • FAME Lab, Department of Exercise Science, University of Thessaly

参与标准

研究人员寻找符合特定描述的人,称为资格标准。这些标准的一些例子是一个人的一般健康状况或先前的治疗。

资格标准

适合学习的年龄

14年 至 17年 (孩子)

接受健康志愿者

是的

有资格学习的性别

全部

描述

Inclusion Criteria:

  • Healthy adolescent athletes

Exclusion Criteria:

  • Diagnosed chronic medical condition;
  • Symptoms of acute illness;
  • Recent (past 4 weeks) usage of medications known to affect the circulatory system, the thyroid, the pituitary function, or the metabolic status.

学习计划

本节提供研究计划的详细信息,包括研究的设计方式和研究的衡量标准。

研究是如何设计的?

设计细节

  • 主要用途:预防
  • 分配:随机化
  • 介入模型:交叉作业
  • 屏蔽:单身的

武器和干预

参与者组/臂
干预/治疗
实验性的:Pre-cooling scenario
One hour before a tennis match, the pre-cooling group was wearing a Cooling Cap (WElkins Sideline Cooling System, SCS) for 45 minutes.
One hour before a tennis match, participants were wearing a Cooling Cap (WElkins Sideline Cooling System, SCS) for 45 minutes. During the tennis match the following variables were monitored: heart rate, core temperature, skin temperature, thermal sensation and comfort, rating of perceived exertion and hydration status.
假比较器:Sham evaluation
Participants were monitored during a usual game without any kind of pre-cooling strategy
During a tennis match the following variables were monitored: heart rate, core temperature, skin temperature, thermal sensation and comfort, rating of perceived exertion and hydration status.

研究衡量的是什么?

主要结果指标

结果测量
措施说明
大体时间
Heart rate
大体时间:Up to 4 hours, during a one complete tennis match
Heart rate data were continuously monitored using a Polar Team system (Polar® Team 2, Polar Electro Oy, Kempele, Finland
Up to 4 hours, during a one complete tennis match
Core temperature
大体时间:Up to 4 hours, during a one complete tennis match
Visceral temperature was continuously recorded throughout the match using telemetric pills (BodyCap, Caen, France)
Up to 4 hours, during a one complete tennis match
Skin temperature
大体时间:Up to 4 hours, during a one complete tennis match
Skin temperature was continuously recorded throughout the match using iBUTTON sensors (type DS1921 H, Maxim/Dallas Semiconductor Corp., USA)
Up to 4 hours, during a one complete tennis match
Change from baseline thermal comfort at after each set
大体时间:Change from baseline up to 1 hour after each set and up to 4 hours at the end of the match
Thermal comfort was assessed via the thermal comfort scale (1 = comfortable; 5 = extremely uncomfortable).
Change from baseline up to 1 hour after each set and up to 4 hours at the end of the match
Change from baseline thermal sensation at after each set
大体时间:Change from baseline up to 1 hour after each set and up to 4 hours at the end of the match
Thermal sensation was assessed via the thermal sensation scale (-3 = cold; +3 = hot)
Change from baseline up to 1 hour after each set and up to 4 hours at the end of the match
Change from baseline rating of perceived exertion at after each set
大体时间:Change from baseline up to 1 hour after each set and up to 4 hours at the end of the match
We used the Borg 20th Scale (6 = no exertion at all; 20 = maximal exertion)
Change from baseline up to 1 hour after each set and up to 4 hours at the end of the match
Change from baseline urine specific gravity (hydration status) at the end of each match
大体时间:Change from baseline up to 4 hours at the end of the tennis match
Urine samples was obtained to evaluate the urine specific gravity. Urine specific gravity (single assessmentno units) was assessed using a refractometer (PAL-10S, ATAGO CO., LTD., Fukaya, Saitama Prefecture, Japan). Urine color was assessed using a urine color scale
Change from baseline up to 4 hours at the end of the tennis match
Match - play characteristics (i.e., performance)
大体时间:Up to 4 hours, during a one complete tennis match
They were recorded by analyzing the video footage from the match. The quantitative performance indices assessed were: games and points won in each set and normalized to the number of games and points recorded in each set, respectively. Unforced errors, first and second serve accuracy, aces, shots per rally and direction changes in each point calculated. Point's duration, between point-duration as well the effective point time calculated. The effective point time starting with the ball toss of the serve and ending when the ball passed the player or bounced twice on court. In case of double fault, starting time recorded from the beginning of the second serve.
Up to 4 hours, during a one complete tennis match
Air temperature
大体时间:Up to 4 hours, during a one complete tennis match
It was measured continuously using a portable weather station (Kestrel 5500FW Fire Weather Meter Pro, USA) placed 1 meter above the ground according to the manufacturer's
Up to 4 hours, during a one complete tennis match
Relative humidity
大体时间:Up to 4 hours, during a one complete tennis match
It was measured continuously using a portable weather station (Kestrel 5500FW Fire Weather Meter Pro, USA) placed 1 meter above the ground according to the manufacturer's guidelines
Up to 4 hours, during a one complete tennis match
Wind speed
大体时间:Up to 4 hours, during a one complete tennis match
It was measured continuously using a portable weather station (Kestrel 5500FW Fire Weather Meter Pro, USA) placed 1 meter above the ground according to the manufacturer's guidelines
Up to 4 hours, during a one complete tennis match
Solar radiation
大体时间:Up to 4 hours, during a one complete tennis match
It was measured continuously using a portable weather station (Kestrel 5500FW Fire Weather Meter Pro, USA) placed 1 meter above the ground according to the manufacturer's guidelines. Solar radiation is measured directly by the device of portable weather station.
Up to 4 hours, during a one complete tennis match

合作者和调查者

在这里您可以找到参与这项研究的人员和组织。

赞助

出版物和有用的链接

负责输入研究信息的人员自愿提供这些出版物。这些可能与研究有关。

研究记录日期

这些日期跟踪向 ClinicalTrials.gov 提交研究记录和摘要结果的进度。研究记录和报告的结果由国家医学图书馆 (NLM) 审查,以确保它们在发布到公共网站之前符合特定的质量控制标准。

研究主要日期

学习开始 (实际的)

2018年8月1日

初级完成 (实际的)

2018年9月30日

研究完成 (实际的)

2018年9月30日

研究注册日期

首次提交

2019年12月7日

首先提交符合 QC 标准的

2019年12月12日

首次发布 (实际的)

2019年12月13日

研究记录更新

最后更新发布 (实际的)

2019年12月13日

上次提交的符合 QC 标准的更新

2019年12月12日

最后验证

2019年12月1日

更多信息

与本研究相关的术语

其他相关的 MeSH 术语

其他研究编号

  • 8. Tennis pre-cooling

计划个人参与者数据 (IPD)

计划共享个人参与者数据 (IPD)?

未定

药物和器械信息、研究文件

研究美国 FDA 监管的药品

不

研究美国 FDA 监管的设备产品

不

此信息直接从 clinicaltrials.gov 网站检索,没有任何更改。如果您有任何更改、删除或更新研究详细信息的请求,请联系 register@clinicaltrials.gov. clinicaltrials.gov 上实施更改,我们的网站上也会自动更新.

订阅