Esta página foi traduzida automaticamente e a precisão da tradução não é garantida. Por favor, consulte o versão em inglês para um texto fonte.

Impact of Pre-cooling in Adolescent Tennis Athletes

12 de dezembro de 2019 atualizado por: Petros Dinas

Impact of Pre-cooling in Adolescent Athletes While Playing Tennis in Hot Conditions

Many tennis tournaments are played outdoors in hot and humid conditions, which poses a significant challenge particularly for children athletes. The purpose of this investigation is to examine if a precooling method can reduce thermal strain and consequently improve the performance of adolescent tennis athletes while exercising in hot conditions.

Visão geral do estudo

Descrição detalhada

Matches were conducted on hard-court surfaces separated by 24h (n=4 pairs) or 144h (n=1pair) between 9am and 6pm and were played in winning two sets. Participants were paired according to their level of play and competed against the same component at the same time of the day in both matches.

Three hours before the start of their scheduled match, each player ingested a telemetric pill in order to estimate the visceral temperature. Upon arrival, all participants provided a urine sample for assessment of urine specific gravity as an indicator of their hydration status and they emptied their bladders before were weighed. They were weighed twice, at baseline and at the end of the match with a precision weight scale (Kern DE 150K2D, KERN & SOHN GmbH, Balingen, Germany). During the match the participants consumed water and any other sport drink and food ad libitum. The total weight of the players' food and fluids that was consumed was measured using a precision weight scale. If participants wished to urinate during the match, they were asked to use a urine cup and their urine was weighed.

One hour before the match, the precooling group was wearing a Cooling Cap (WElkins Sideline Cooling System, SCS) for 45 minutes. On removal from a -20oC freezer, the cap surface was 10.7±2.5oC. After 45 minutes, participants removed the cap and they performed a 5 minutes standardized warm-up (running around the court and running exercises from baseline to net and back to baseline) and 10 min tennis specific warm up (rallies and serves) on court. Each participant, before the warm-up, was outfitted with a heart rate chest strap and iBUTTON sensors at four sites of the body (chest, upper arm, thigh and calf).

The scoring and timing characteristics of the matches complied with 2016 ITF rules. Three new balls were used for each match with the players retrieving balls between points. Matches were filmed from one end of the court, using a digital video camera (Sony DCR-VX2000E PAL, Japan). Participants were performed on perceptual measurements at baseline, after each set, and at the end of the match.

Thermoregulatory, cardiovascular and perceptual responses were recorded with standardized techniques: 1) visceral temperature using telemetric pill (BodyCap, Caen, France) was continuously recorded throughout the match; 2) skin temperature using iBUTTON sensors (type DS1921 H, Maxim/Dallas Semiconductor Corp., USA) on chest, upper arm, thigh and calf was recorded continuously; 3) heart rate (HR) variability data were sampled through short-range telemetry at 1,000 Hz with a Polar RS800CX (Polar Electro , Kempele, Finland). The heart rate monitor signal will be transferred to the Polar Precision Performance Software (release 3.00; Polar Electro Oy); 4) thermal comfort (scale 1-5), thermal sensation (scale 1-10) and rating of perceived exertion using standardized questionnaires were recorded at baseline, after each set, and at the end of the match.

Hydration status was recorded with urine specific gravity. All the collected urine samples will be analyzed using a refractrometer (Atago, Tokyo, Japan) for the determination of urine specific gravity. Euhydration will be defined as urine specific gravity <1.02 according to internationally accepted standards.

A digital video camera (Sony DCR-VX2000E PAL, Japan) was used to record the match - play characteristics. The footage was used to conduct the retrospective notational analysis. The quantitative performance indices that assessed had been: games and points won in each set and normalized to the number of games and points that record in each set respectively. Also unforced errors, first and second serve accuracy, aces, shots per rally and direction changes in each point calculated. Point's duration, between point-duration as well the effective point time calculated. The effective point time starting with the ball toss of the serve and ending when the ball passed the player or bounced twice on court. In case of double fault, starting time recorded from the beginning of the second serve.

Environmental data including air temperature, relative humidity, and wind speed were measured continuously using a portable weather station (Kestrel 5500FW Fire Weather Meter Pro, USA). The weather station was placed 1 meter above the ground according to the manufacturer's guidelines.

Tipo de estudo

Intervencional

Inscrição (Real)

8

Estágio

  • Não aplicável

Contactos e Locais

Esta seção fornece os detalhes de contato para aqueles que conduzem o estudo e informações sobre onde este estudo está sendo realizado.

Locais de estudo

    • Thessaly
      • Tríkala, Thessaly, Grécia, 42100
        • FAME Lab, Department of Exercise Science, University of Thessaly

Critérios de participação

Os pesquisadores procuram pessoas que se encaixem em uma determinada descrição, chamada de critérios de elegibilidade. Alguns exemplos desses critérios são a condição geral de saúde de uma pessoa ou tratamentos anteriores.

Critérios de elegibilidade

Idades elegíveis para estudo

14 anos a 17 anos (Filho)

Aceita Voluntários Saudáveis

Sim

Gêneros Elegíveis para o Estudo

Tudo

Descrição

Inclusion Criteria:

  • Healthy adolescent athletes

Exclusion Criteria:

  • Diagnosed chronic medical condition;
  • Symptoms of acute illness;
  • Recent (past 4 weeks) usage of medications known to affect the circulatory system, the thyroid, the pituitary function, or the metabolic status.

Plano de estudo

Esta seção fornece detalhes do plano de estudo, incluindo como o estudo é projetado e o que o estudo está medindo.

Como o estudo é projetado?

Detalhes do projeto

  • Finalidade Principal: Prevenção
  • Alocação: Randomizado
  • Modelo Intervencional: Atribuição cruzada
  • Mascaramento: Solteiro

Armas e Intervenções

Grupo de Participantes / Braço
Intervenção / Tratamento
Experimental: Pre-cooling scenario
One hour before a tennis match, the pre-cooling group was wearing a Cooling Cap (WElkins Sideline Cooling System, SCS) for 45 minutes.
One hour before a tennis match, participants were wearing a Cooling Cap (WElkins Sideline Cooling System, SCS) for 45 minutes. During the tennis match the following variables were monitored: heart rate, core temperature, skin temperature, thermal sensation and comfort, rating of perceived exertion and hydration status.
Comparador Falso: Sham evaluation
Participants were monitored during a usual game without any kind of pre-cooling strategy
During a tennis match the following variables were monitored: heart rate, core temperature, skin temperature, thermal sensation and comfort, rating of perceived exertion and hydration status.

O que o estudo está medindo?

Medidas de resultados primários

Medida de resultado
Descrição da medida
Prazo
Heart rate
Prazo: Up to 4 hours, during a one complete tennis match
Heart rate data were continuously monitored using a Polar Team system (Polar® Team 2, Polar Electro Oy, Kempele, Finland
Up to 4 hours, during a one complete tennis match
Core temperature
Prazo: Up to 4 hours, during a one complete tennis match
Visceral temperature was continuously recorded throughout the match using telemetric pills (BodyCap, Caen, France)
Up to 4 hours, during a one complete tennis match
Skin temperature
Prazo: Up to 4 hours, during a one complete tennis match
Skin temperature was continuously recorded throughout the match using iBUTTON sensors (type DS1921 H, Maxim/Dallas Semiconductor Corp., USA)
Up to 4 hours, during a one complete tennis match
Change from baseline thermal comfort at after each set
Prazo: Change from baseline up to 1 hour after each set and up to 4 hours at the end of the match
Thermal comfort was assessed via the thermal comfort scale (1 = comfortable; 5 = extremely uncomfortable).
Change from baseline up to 1 hour after each set and up to 4 hours at the end of the match
Change from baseline thermal sensation at after each set
Prazo: Change from baseline up to 1 hour after each set and up to 4 hours at the end of the match
Thermal sensation was assessed via the thermal sensation scale (-3 = cold; +3 = hot)
Change from baseline up to 1 hour after each set and up to 4 hours at the end of the match
Change from baseline rating of perceived exertion at after each set
Prazo: Change from baseline up to 1 hour after each set and up to 4 hours at the end of the match
We used the Borg 20th Scale (6 = no exertion at all; 20 = maximal exertion)
Change from baseline up to 1 hour after each set and up to 4 hours at the end of the match
Change from baseline urine specific gravity (hydration status) at the end of each match
Prazo: Change from baseline up to 4 hours at the end of the tennis match
Urine samples was obtained to evaluate the urine specific gravity. Urine specific gravity (single assessmentno units) was assessed using a refractometer (PAL-10S, ATAGO CO., LTD., Fukaya, Saitama Prefecture, Japan). Urine color was assessed using a urine color scale
Change from baseline up to 4 hours at the end of the tennis match
Match - play characteristics (i.e., performance)
Prazo: Up to 4 hours, during a one complete tennis match
They were recorded by analyzing the video footage from the match. The quantitative performance indices assessed were: games and points won in each set and normalized to the number of games and points recorded in each set, respectively. Unforced errors, first and second serve accuracy, aces, shots per rally and direction changes in each point calculated. Point's duration, between point-duration as well the effective point time calculated. The effective point time starting with the ball toss of the serve and ending when the ball passed the player or bounced twice on court. In case of double fault, starting time recorded from the beginning of the second serve.
Up to 4 hours, during a one complete tennis match
Air temperature
Prazo: Up to 4 hours, during a one complete tennis match
It was measured continuously using a portable weather station (Kestrel 5500FW Fire Weather Meter Pro, USA) placed 1 meter above the ground according to the manufacturer's
Up to 4 hours, during a one complete tennis match
Relative humidity
Prazo: Up to 4 hours, during a one complete tennis match
It was measured continuously using a portable weather station (Kestrel 5500FW Fire Weather Meter Pro, USA) placed 1 meter above the ground according to the manufacturer's guidelines
Up to 4 hours, during a one complete tennis match
Wind speed
Prazo: Up to 4 hours, during a one complete tennis match
It was measured continuously using a portable weather station (Kestrel 5500FW Fire Weather Meter Pro, USA) placed 1 meter above the ground according to the manufacturer's guidelines
Up to 4 hours, during a one complete tennis match
Solar radiation
Prazo: Up to 4 hours, during a one complete tennis match
It was measured continuously using a portable weather station (Kestrel 5500FW Fire Weather Meter Pro, USA) placed 1 meter above the ground according to the manufacturer's guidelines. Solar radiation is measured directly by the device of portable weather station.
Up to 4 hours, during a one complete tennis match

Colaboradores e Investigadores

É aqui que você encontrará pessoas e organizações envolvidas com este estudo.

Patrocinador

Publicações e links úteis

A pessoa responsável por inserir informações sobre o estudo fornece voluntariamente essas publicações. Estes podem ser sobre qualquer coisa relacionada ao estudo.

Datas de registro do estudo

Essas datas acompanham o progresso do registro do estudo e os envios de resumo dos resultados para ClinicalTrials.gov. Os registros do estudo e os resultados relatados são revisados ​​pela National Library of Medicine (NLM) para garantir que atendam aos padrões específicos de controle de qualidade antes de serem publicados no site público.

Datas Principais do Estudo

Início do estudo (Real)

1 de agosto de 2018

Conclusão Primária (Real)

30 de setembro de 2018

Conclusão do estudo (Real)

30 de setembro de 2018

Datas de inscrição no estudo

Enviado pela primeira vez

7 de dezembro de 2019

Enviado pela primeira vez que atendeu aos critérios de CQ

12 de dezembro de 2019

Primeira postagem (Real)

13 de dezembro de 2019

Atualizações de registro de estudo

Última Atualização Postada (Real)

13 de dezembro de 2019

Última atualização enviada que atendeu aos critérios de controle de qualidade

12 de dezembro de 2019

Última verificação

1 de dezembro de 2019

Mais Informações

Termos relacionados a este estudo

Termos MeSH relevantes adicionais

Outros números de identificação do estudo

  • 8. Tennis pre-cooling

Plano para dados de participantes individuais (IPD)

Planeja compartilhar dados de participantes individuais (IPD)?

INDECISO

Informações sobre medicamentos e dispositivos, documentos de estudo

Estuda um medicamento regulamentado pela FDA dos EUA

Não

Estuda um produto de dispositivo regulamentado pela FDA dos EUA

Não

Essas informações foram obtidas diretamente do site clinicaltrials.gov sem nenhuma alteração. Se você tiver alguma solicitação para alterar, remover ou atualizar os detalhes do seu estudo, entre em contato com register@clinicaltrials.gov. Assim que uma alteração for implementada em clinicaltrials.gov, ela também será atualizada automaticamente em nosso site .

Se inscrever