Patient Satisfaction and OHRQoL In Removable Versus Fixed Implant Prostheses
Assessment Of Patient Satisfaction and Oral-health Related Quality of Life In Completely Edentulous Patients Receiving Removable Implant Overdentures Versus Fixed Implant Overdentures: A Randomized Clinical Trial
研究概览
地位
条件
详细说明
Interventions
General operative procedures:
Once the eligibility criteria were fulfilled in a patient, new complete maxillary and mandibular dentures were fabricated for this patient to allow for prosthetically driven implant placement. 4 implants were placed interforaminally so that they were parallel to each other. If the patient had an existing satisfactory denture, that was delivered at least six months ago, it was evaluated for retention, fit, support, stability, occlusion and esthetics. New and old dentures were later used for constructing the scan appliances.
The patients were randomly assigned into two groups with an allocation ratio 1:1. Simple randomization was done by preparing sequentially-numbered, opaque, sealed envelopes, that contained two-times folded cards with the treatment group written inside. Accordingly, the patients were assigned either to group T (control treatment/ telescopic retained implant supported removable overdentures) or group S (test treatment/ screw retained implant supported fixed prosthesis).
The intervention arm : Engaging (Internal hex) cylindrical, plastic patterns (Octa plastic cylinder, multi unit abutment, Red, Dentis, Daegu -Korea) were used to construct the primary copings of the telescopic prosthesis.The finished primary copings were scanned using a lab scanner (Shera Echo-scan 7. Dental Wings, Montreal-Canada). This was necessary to design and to mill the wax pattern of the secondary copings using CAD/CAM technology (Dental Wings Software, Dental Wings, Montreal -Canada). Secondary coping was designed to properly fit to the primary coping. The framework was then tried in. At that time it was ready for its intra-oral luting to the secondary copings.
the control treatment: Once adequate fit of the framework of the hybrid prosthesis was achieved, the wax of the trial denture was converted into heat-cured acrylic resin using conventional packing and flasking techniques. The prosthesis was finished, polished and screwed in the patient's mouth.
Lack of blinding of the operator, the participants and the assessor (patient) due to the obvious dissimilarity between the treatment arms, could have created performance and assessment bias. In an attempt to decrease the performance bias, randomization was delayed until the abutments were connected. When the prosthesis was delivered to the patient, they were requested to answer OHIP-14 and patient satisfaction questionnaires 2 weeks after prosthetic insertion, then 3, 6 and 12 months later.
The aim of this RCT was to evaluate patient satisfaction and oral-health related quality of life in completely edentulous patients receiving removable implant overdentures versus fixed implant hybrid restorations.
Data were statistically described in terms of mean +/- standard deviation (+/- SD), median and range. Comparison of ordinal variables between the study groups was done using Mann Whitney U test for independent samples. Within group comparison of the ordinal data was done using Friedmann test to detect significant differences between time in periods. This was followed by Wilcoxon signed rank test for paired comparisons. Two sided p values less than 0.05 was considered statistically significant. Additionally, a correlation between relevant domains of the OHIP-14 and the patient satisfaction questionnaires was done using Spearman rank correlation test. All statistical calculations were done using computer program IBM SPSS (Statistical Package for the Social Science; IBM Corp, Armonk, NY, USA) release 22 for Microsoft Windows
研究类型
注册 (实际的)
阶段
- 不适用
联系人和位置
学习地点
-
-
Manial
-
Cairo、Manial、埃及、12911
- Faculty of Dentistry
-
-
参与标准
资格标准
适合学习的年龄
接受健康志愿者
有资格学习的性别
描述
Inclusion Criteria:
- Completely edentulous male patients with an age range from 40- 70 years.
- Patients with a HbA1c equal to or less than 7
- All patients should have normal maxillo-mandibular relationship (Angle class I).
- Patients should have maxillary and mandibular ridges at least 7mm in width and 13 mm in height in the interforaminal areas and in the esthetic zones (premolar to premolar regions), respectively. This accommodated a pre-planned implant size of 3.7mm x 10 or 11mm.
- The maxillary and mandibular ridges should be covered by keratinized attached mucosa at least 5mm in width.
- An interarch space between the edentulous maxillary and mandibular ridges should not be less than 22 mm to accommodate the planned maxillary and mandibular implant-supported prostheses. This was confirmed by mounted diagnostic casts.
- Patients who were cooperative and who were psychologically and mentally stable as revealed from the initial interview with the patients were considered eligible.
Exclusion Criteria:
Females were excluded on purpose to prevent failures associated with osteoporosis and to avoid gender variability which definitely affects the results of patient satisfaction and OHIP.
2. Patients requiring hard or, soft tissue grafting of the proposed implant sites.
3. Heavy smokers (more than 10 cigarettes / day) or patients with para-functional habits like clenching or bruxism were excluded. This was important to decrease the risk of implant failure.
4. Patients with temporo-mandibular joint disorders were considered ineligible because of the expected occlusal disturbances.
5. Patients with systemic disease that might contra-indicate implants placement or affect osseointegration e.g. uncontrolled diabetes.
6. Patients who took chemo-or radiotherapy or any drug that might counter-affect the healing process or the quality of bone.
学习计划
研究是如何设计的?
设计细节
- 主要用途:治疗
- 分配:随机化
- 介入模型:并行分配
- 屏蔽:无(打开标签)
武器和干预
参与者组/臂 |
干预/治疗 |
|---|---|
|
实验性的:Fixed implant supported prosthesis
the prosthesis is an all-on-four prosthesis composed of a hybrid prosthesis.
a metal framework, acrylic resin denture base and acrylic resin teeth
|
Framework of the hybrid prosthesis is waxed using plastic copings attached to multiunit abutments.
once the framework is finished , bite is recorded, teeth are set up and the waxed up prosthesis are tried in.
IF accepted the wax is eliminated the wax up denture is converted inti heat cured acrylic resin
|
|
有源比较器:Removable implant supported prosthesis
the prosthesis is an all-on-four prosthesis composed of a telescopic retained overdenture, both primary and secondary copings are custom made.
the secondary copings are conncetd via a metal framework
|
The wax of the trial denture was converted into heat-cured acrylic resin using conventional packing and flasking techniques.
The prosthesis was finished, polished and screwed in the patient's mouth.
Engaging (Internal hex) cylindrical, plastic patterns (Octa plastic cylinder, multi unit abutment, Red, Dentis, Daegu -Korea) were used to construct the primary copings of the telescopic prosthesis.The finished primary copings were scanned using a lab scanner (Shera Echo-scan 7. Dental Wings, Montreal-Canada).
This was necessary to design and to mill the wax pattern of the secondary copings using CAD/CAM technology (Dental Wings Software, Dental Wings, Montreal -Canada).
Secondary coping was designed to properly fit to the primary coping.
The framework was then tried in.
At that time it was ready for its intra-oral luting to the secondary copings.
|
研究衡量的是什么?
主要结果指标
结果测量 |
措施说明 |
大体时间 |
|---|---|---|
|
patient satisfaction
大体时间:2 weeks after prosthetic insertion- 1 year
|
questionnaire.
The patient satisfaction questionnaire is composed of 14 questions concerned with esthetics, speech, mastication, operative and prosthetic procedures, incidence of complications, pre-operative instructions, total time interval, cost, operator, hygienic procedures, overall experience as well as the willingness to repeat or refer others for the procedure.
|
2 weeks after prosthetic insertion- 1 year
|
次要结果测量
结果测量 |
措施说明 |
大体时间 |
|---|---|---|
|
oral health related quality of life
大体时间:2 weeks after prosthetic insertion- 1 year
|
OHIP-14 scoring
|
2 weeks after prosthetic insertion- 1 year
|
合作者和调查者
调查人员
- 首席研究员:Amira kheidr, masters、Cairo University
- 研究主任:Amr El Khadem, phd、Cairo University
- 学习椅:Samira Ibrahim, phd、Cairo University
研究记录日期
研究主要日期
学习开始 (实际的)
初级完成 (实际的)
研究完成 (实际的)
研究注册日期
首次提交
首先提交符合 QC 标准的
首次发布 (实际的)
研究记录更新
最后更新发布 (实际的)
上次提交的符合 QC 标准的更新
最后验证
更多信息
此信息直接从 clinicaltrials.gov 网站检索,没有任何更改。如果您有任何更改、删除或更新研究详细信息的请求,请联系 register@clinicaltrials.gov. clinicaltrials.gov 上实施更改,我们的网站上也会自动更新.