Tato stránka byla automaticky přeložena a přesnost překladu není zaručena. Podívejte se prosím na anglická verze pro zdrojový text.

Patient Satisfaction and OHRQoL In Removable Versus Fixed Implant Prostheses

8. března 2021 aktualizováno: Iman Abd-ElWahab Radi, PhD

Assessment Of Patient Satisfaction and Oral-health Related Quality of Life In Completely Edentulous Patients Receiving Removable Implant Overdentures Versus Fixed Implant Overdentures: A Randomized Clinical Trial

Objectives to evaluate the oral health-related quality of life and patient satisfaction in completely edentulous patients, when restored by maxillary and mandibular fixed (screw-retained) or removable telescopic retained implant supported prosthesis. 19 patients were randomized to receive either a fixed or a removable maxillary and mandibular full arch implant prosthesis. They were then asked to answer the OHIP-14 and a patient satisfaction questionnaire at 2 weeks, 3, 6 and 12 months post-prosthetic insertion.

Přehled studie

Detailní popis

Interventions

General operative procedures:

Once the eligibility criteria were fulfilled in a patient, new complete maxillary and mandibular dentures were fabricated for this patient to allow for prosthetically driven implant placement. 4 implants were placed interforaminally so that they were parallel to each other. If the patient had an existing satisfactory denture, that was delivered at least six months ago, it was evaluated for retention, fit, support, stability, occlusion and esthetics. New and old dentures were later used for constructing the scan appliances.

The patients were randomly assigned into two groups with an allocation ratio 1:1. Simple randomization was done by preparing sequentially-numbered, opaque, sealed envelopes, that contained two-times folded cards with the treatment group written inside. Accordingly, the patients were assigned either to group T (control treatment/ telescopic retained implant supported removable overdentures) or group S (test treatment/ screw retained implant supported fixed prosthesis).

The intervention arm : Engaging (Internal hex) cylindrical, plastic patterns (Octa plastic cylinder, multi unit abutment, Red, Dentis, Daegu -Korea) were used to construct the primary copings of the telescopic prosthesis.The finished primary copings were scanned using a lab scanner (Shera Echo-scan 7. Dental Wings, Montreal-Canada). This was necessary to design and to mill the wax pattern of the secondary copings using CAD/CAM technology (Dental Wings Software, Dental Wings, Montreal -Canada). Secondary coping was designed to properly fit to the primary coping. The framework was then tried in. At that time it was ready for its intra-oral luting to the secondary copings.

the control treatment: Once adequate fit of the framework of the hybrid prosthesis was achieved, the wax of the trial denture was converted into heat-cured acrylic resin using conventional packing and flasking techniques. The prosthesis was finished, polished and screwed in the patient's mouth.

Lack of blinding of the operator, the participants and the assessor (patient) due to the obvious dissimilarity between the treatment arms, could have created performance and assessment bias. In an attempt to decrease the performance bias, randomization was delayed until the abutments were connected. When the prosthesis was delivered to the patient, they were requested to answer OHIP-14 and patient satisfaction questionnaires 2 weeks after prosthetic insertion, then 3, 6 and 12 months later.

The aim of this RCT was to evaluate patient satisfaction and oral-health related quality of life in completely edentulous patients receiving removable implant overdentures versus fixed implant hybrid restorations.

Data were statistically described in terms of mean +/- standard deviation (+/- SD), median and range. Comparison of ordinal variables between the study groups was done using Mann Whitney U test for independent samples. Within group comparison of the ordinal data was done using Friedmann test to detect significant differences between time in periods. This was followed by Wilcoxon signed rank test for paired comparisons. Two sided p values less than 0.05 was considered statistically significant. Additionally, a correlation between relevant domains of the OHIP-14 and the patient satisfaction questionnaires was done using Spearman rank correlation test. All statistical calculations were done using computer program IBM SPSS (Statistical Package for the Social Science; IBM Corp, Armonk, NY, USA) release 22 for Microsoft Windows

Typ studie

Intervenční

Zápis (Aktuální)

19

Fáze

  • Nelze použít

Kontakty a umístění

Tato část poskytuje kontaktní údaje pro ty, kteří studii provádějí, a informace o tom, kde se tato studie provádí.

Studijní místa

    • Manial
      • Cairo, Manial, Egypt, 12911
        • Faculty of Dentistry

Kritéria účasti

Výzkumníci hledají lidi, kteří odpovídají určitému popisu, kterému se říká kritéria způsobilosti. Některé příklady těchto kritérií jsou celkový zdravotní stav osoby nebo předchozí léčba.

Kritéria způsobilosti

Věk způsobilý ke studiu

40 let až 70 let (Dospělý, Starší dospělý)

Přijímá zdravé dobrovolníky

Ne

Pohlaví způsobilá ke studiu

Mužský

Popis

Inclusion Criteria:

  1. Completely edentulous male patients with an age range from 40- 70 years.
  2. Patients with a HbA1c equal to or less than 7
  3. All patients should have normal maxillo-mandibular relationship (Angle class I).
  4. Patients should have maxillary and mandibular ridges at least 7mm in width and 13 mm in height in the interforaminal areas and in the esthetic zones (premolar to premolar regions), respectively. This accommodated a pre-planned implant size of 3.7mm x 10 or 11mm.
  5. The maxillary and mandibular ridges should be covered by keratinized attached mucosa at least 5mm in width.
  6. An interarch space between the edentulous maxillary and mandibular ridges should not be less than 22 mm to accommodate the planned maxillary and mandibular implant-supported prostheses. This was confirmed by mounted diagnostic casts.
  7. Patients who were cooperative and who were psychologically and mentally stable as revealed from the initial interview with the patients were considered eligible.

Exclusion Criteria:

  • Females were excluded on purpose to prevent failures associated with osteoporosis and to avoid gender variability which definitely affects the results of patient satisfaction and OHIP.

    2. Patients requiring hard or, soft tissue grafting of the proposed implant sites.

    3. Heavy smokers (more than 10 cigarettes / day) or patients with para-functional habits like clenching or bruxism were excluded. This was important to decrease the risk of implant failure.

    4. Patients with temporo-mandibular joint disorders were considered ineligible because of the expected occlusal disturbances.

    5. Patients with systemic disease that might contra-indicate implants placement or affect osseointegration e.g. uncontrolled diabetes.

    6. Patients who took chemo-or radiotherapy or any drug that might counter-affect the healing process or the quality of bone.

Studijní plán

Tato část poskytuje podrobnosti o studijním plánu, včetně toho, jak je studie navržena a co studie měří.

Jak je studie koncipována?

Detaily designu

  • Primární účel: Léčba
  • Přidělení: Randomizované
  • Intervenční model: Paralelní přiřazení
  • Maskování: Žádné (otevřený štítek)

Zbraně a zásahy

Skupina účastníků / Arm
Intervence / Léčba
Experimentální: Fixed implant supported prosthesis
the prosthesis is an all-on-four prosthesis composed of a hybrid prosthesis. a metal framework, acrylic resin denture base and acrylic resin teeth
Framework of the hybrid prosthesis is waxed using plastic copings attached to multiunit abutments. once the framework is finished , bite is recorded, teeth are set up and the waxed up prosthesis are tried in. IF accepted the wax is eliminated the wax up denture is converted inti heat cured acrylic resin
Aktivní komparátor: Removable implant supported prosthesis
the prosthesis is an all-on-four prosthesis composed of a telescopic retained overdenture, both primary and secondary copings are custom made. the secondary copings are conncetd via a metal framework
The wax of the trial denture was converted into heat-cured acrylic resin using conventional packing and flasking techniques. The prosthesis was finished, polished and screwed in the patient's mouth. Engaging (Internal hex) cylindrical, plastic patterns (Octa plastic cylinder, multi unit abutment, Red, Dentis, Daegu -Korea) were used to construct the primary copings of the telescopic prosthesis.The finished primary copings were scanned using a lab scanner (Shera Echo-scan 7. Dental Wings, Montreal-Canada). This was necessary to design and to mill the wax pattern of the secondary copings using CAD/CAM technology (Dental Wings Software, Dental Wings, Montreal -Canada). Secondary coping was designed to properly fit to the primary coping. The framework was then tried in. At that time it was ready for its intra-oral luting to the secondary copings.

Co je měření studie?

Primární výstupní opatření

Měření výsledku
Popis opatření
Časové okno
patient satisfaction
Časové okno: 2 weeks after prosthetic insertion- 1 year
questionnaire. The patient satisfaction questionnaire is composed of 14 questions concerned with esthetics, speech, mastication, operative and prosthetic procedures, incidence of complications, pre-operative instructions, total time interval, cost, operator, hygienic procedures, overall experience as well as the willingness to repeat or refer others for the procedure.
2 weeks after prosthetic insertion- 1 year

Sekundární výstupní opatření

Měření výsledku
Popis opatření
Časové okno
oral health related quality of life
Časové okno: 2 weeks after prosthetic insertion- 1 year
OHIP-14 scoring
2 weeks after prosthetic insertion- 1 year

Spolupracovníci a vyšetřovatelé

Zde najdete lidi a organizace zapojené do této studie.

Vyšetřovatelé

  • Vrchní vyšetřovatel: Amira kheidr, masters, Cairo University
  • Ředitel studie: Amr El Khadem, phd, Cairo University
  • Studijní židle: Samira Ibrahim, phd, Cairo University

Termíny studijních záznamů

Tato data sledují průběh záznamů studie a předkládání souhrnných výsledků na ClinicalTrials.gov. Záznamy ze studií a hlášené výsledky jsou před zveřejněním na veřejné webové stránce přezkoumány Národní lékařskou knihovnou (NLM), aby se ujistily, že splňují specifické standardy kontroly kvality.

Hlavní termíny studia

Začátek studia (Aktuální)

1. listopadu 2017

Primární dokončení (Aktuální)

30. září 2018

Dokončení studie (Aktuální)

28. srpna 2019

Termíny zápisu do studia

První předloženo

24. prosince 2020

První předloženo, které splnilo kritéria kontroly kvality

1. ledna 2021

První zveřejněno (Aktuální)

5. ledna 2021

Aktualizace studijních záznamů

Poslední zveřejněná aktualizace (Aktuální)

10. března 2021

Odeslaná poslední aktualizace, která splnila kritéria kontroly kvality

8. března 2021

Naposledy ověřeno

1. března 2021

Více informací

Termíny související s touto studií

Další identifikační čísla studie

  • 151017

Plán pro data jednotlivých účastníků (IPD)

Plánujete sdílet data jednotlivých účastníků (IPD)?

Ne

Informace o lécích a zařízeních, studijní dokumenty

Studuje lékový produkt regulovaný americkým FDA

Ne

Studuje produkt zařízení regulovaný americkým úřadem FDA

Ne

Tyto informace byly beze změn načteny přímo z webu clinicaltrials.gov. Máte-li jakékoli požadavky na změnu, odstranění nebo aktualizaci podrobností studie, kontaktujte prosím register@clinicaltrials.gov. Jakmile bude změna implementována na clinicaltrials.gov, bude automaticky aktualizována i na našem webu .