Esta página foi traduzida automaticamente e a precisão da tradução não é garantida. Por favor, consulte o versão em inglês para um texto fonte.

Patient Satisfaction and OHRQoL In Removable Versus Fixed Implant Prostheses

8 de março de 2021 atualizado por: Iman Abd-ElWahab Radi, PhD

Assessment Of Patient Satisfaction and Oral-health Related Quality of Life In Completely Edentulous Patients Receiving Removable Implant Overdentures Versus Fixed Implant Overdentures: A Randomized Clinical Trial

Objectives to evaluate the oral health-related quality of life and patient satisfaction in completely edentulous patients, when restored by maxillary and mandibular fixed (screw-retained) or removable telescopic retained implant supported prosthesis. 19 patients were randomized to receive either a fixed or a removable maxillary and mandibular full arch implant prosthesis. They were then asked to answer the OHIP-14 and a patient satisfaction questionnaire at 2 weeks, 3, 6 and 12 months post-prosthetic insertion.

Visão geral do estudo

Descrição detalhada

Interventions

General operative procedures:

Once the eligibility criteria were fulfilled in a patient, new complete maxillary and mandibular dentures were fabricated for this patient to allow for prosthetically driven implant placement. 4 implants were placed interforaminally so that they were parallel to each other. If the patient had an existing satisfactory denture, that was delivered at least six months ago, it was evaluated for retention, fit, support, stability, occlusion and esthetics. New and old dentures were later used for constructing the scan appliances.

The patients were randomly assigned into two groups with an allocation ratio 1:1. Simple randomization was done by preparing sequentially-numbered, opaque, sealed envelopes, that contained two-times folded cards with the treatment group written inside. Accordingly, the patients were assigned either to group T (control treatment/ telescopic retained implant supported removable overdentures) or group S (test treatment/ screw retained implant supported fixed prosthesis).

The intervention arm : Engaging (Internal hex) cylindrical, plastic patterns (Octa plastic cylinder, multi unit abutment, Red, Dentis, Daegu -Korea) were used to construct the primary copings of the telescopic prosthesis.The finished primary copings were scanned using a lab scanner (Shera Echo-scan 7. Dental Wings, Montreal-Canada). This was necessary to design and to mill the wax pattern of the secondary copings using CAD/CAM technology (Dental Wings Software, Dental Wings, Montreal -Canada). Secondary coping was designed to properly fit to the primary coping. The framework was then tried in. At that time it was ready for its intra-oral luting to the secondary copings.

the control treatment: Once adequate fit of the framework of the hybrid prosthesis was achieved, the wax of the trial denture was converted into heat-cured acrylic resin using conventional packing and flasking techniques. The prosthesis was finished, polished and screwed in the patient's mouth.

Lack of blinding of the operator, the participants and the assessor (patient) due to the obvious dissimilarity between the treatment arms, could have created performance and assessment bias. In an attempt to decrease the performance bias, randomization was delayed until the abutments were connected. When the prosthesis was delivered to the patient, they were requested to answer OHIP-14 and patient satisfaction questionnaires 2 weeks after prosthetic insertion, then 3, 6 and 12 months later.

The aim of this RCT was to evaluate patient satisfaction and oral-health related quality of life in completely edentulous patients receiving removable implant overdentures versus fixed implant hybrid restorations.

Data were statistically described in terms of mean +/- standard deviation (+/- SD), median and range. Comparison of ordinal variables between the study groups was done using Mann Whitney U test for independent samples. Within group comparison of the ordinal data was done using Friedmann test to detect significant differences between time in periods. This was followed by Wilcoxon signed rank test for paired comparisons. Two sided p values less than 0.05 was considered statistically significant. Additionally, a correlation between relevant domains of the OHIP-14 and the patient satisfaction questionnaires was done using Spearman rank correlation test. All statistical calculations were done using computer program IBM SPSS (Statistical Package for the Social Science; IBM Corp, Armonk, NY, USA) release 22 for Microsoft Windows

Tipo de estudo

Intervencional

Inscrição (Real)

19

Estágio

  • Não aplicável

Contactos e Locais

Esta seção fornece os detalhes de contato para aqueles que conduzem o estudo e informações sobre onde este estudo está sendo realizado.

Locais de estudo

    • Manial
      • Cairo, Manial, Egito, 12911
        • Faculty of Dentistry

Critérios de participação

Os pesquisadores procuram pessoas que se encaixem em uma determinada descrição, chamada de critérios de elegibilidade. Alguns exemplos desses critérios são a condição geral de saúde de uma pessoa ou tratamentos anteriores.

Critérios de elegibilidade

Idades elegíveis para estudo

40 anos a 70 anos (Adulto, Adulto mais velho)

Aceita Voluntários Saudáveis

Não

Gêneros Elegíveis para o Estudo

Macho

Descrição

Inclusion Criteria:

  1. Completely edentulous male patients with an age range from 40- 70 years.
  2. Patients with a HbA1c equal to or less than 7
  3. All patients should have normal maxillo-mandibular relationship (Angle class I).
  4. Patients should have maxillary and mandibular ridges at least 7mm in width and 13 mm in height in the interforaminal areas and in the esthetic zones (premolar to premolar regions), respectively. This accommodated a pre-planned implant size of 3.7mm x 10 or 11mm.
  5. The maxillary and mandibular ridges should be covered by keratinized attached mucosa at least 5mm in width.
  6. An interarch space between the edentulous maxillary and mandibular ridges should not be less than 22 mm to accommodate the planned maxillary and mandibular implant-supported prostheses. This was confirmed by mounted diagnostic casts.
  7. Patients who were cooperative and who were psychologically and mentally stable as revealed from the initial interview with the patients were considered eligible.

Exclusion Criteria:

  • Females were excluded on purpose to prevent failures associated with osteoporosis and to avoid gender variability which definitely affects the results of patient satisfaction and OHIP.

    2. Patients requiring hard or, soft tissue grafting of the proposed implant sites.

    3. Heavy smokers (more than 10 cigarettes / day) or patients with para-functional habits like clenching or bruxism were excluded. This was important to decrease the risk of implant failure.

    4. Patients with temporo-mandibular joint disorders were considered ineligible because of the expected occlusal disturbances.

    5. Patients with systemic disease that might contra-indicate implants placement or affect osseointegration e.g. uncontrolled diabetes.

    6. Patients who took chemo-or radiotherapy or any drug that might counter-affect the healing process or the quality of bone.

Plano de estudo

Esta seção fornece detalhes do plano de estudo, incluindo como o estudo é projetado e o que o estudo está medindo.

Como o estudo é projetado?

Detalhes do projeto

  • Finalidade Principal: Tratamento
  • Alocação: Randomizado
  • Modelo Intervencional: Atribuição Paralela
  • Mascaramento: Nenhum (rótulo aberto)

Armas e Intervenções

Grupo de Participantes / Braço
Intervenção / Tratamento
Experimental: Fixed implant supported prosthesis
the prosthesis is an all-on-four prosthesis composed of a hybrid prosthesis. a metal framework, acrylic resin denture base and acrylic resin teeth
Framework of the hybrid prosthesis is waxed using plastic copings attached to multiunit abutments. once the framework is finished , bite is recorded, teeth are set up and the waxed up prosthesis are tried in. IF accepted the wax is eliminated the wax up denture is converted inti heat cured acrylic resin
Comparador Ativo: Removable implant supported prosthesis
the prosthesis is an all-on-four prosthesis composed of a telescopic retained overdenture, both primary and secondary copings are custom made. the secondary copings are conncetd via a metal framework
The wax of the trial denture was converted into heat-cured acrylic resin using conventional packing and flasking techniques. The prosthesis was finished, polished and screwed in the patient's mouth. Engaging (Internal hex) cylindrical, plastic patterns (Octa plastic cylinder, multi unit abutment, Red, Dentis, Daegu -Korea) were used to construct the primary copings of the telescopic prosthesis.The finished primary copings were scanned using a lab scanner (Shera Echo-scan 7. Dental Wings, Montreal-Canada). This was necessary to design and to mill the wax pattern of the secondary copings using CAD/CAM technology (Dental Wings Software, Dental Wings, Montreal -Canada). Secondary coping was designed to properly fit to the primary coping. The framework was then tried in. At that time it was ready for its intra-oral luting to the secondary copings.

O que o estudo está medindo?

Medidas de resultados primários

Medida de resultado
Descrição da medida
Prazo
patient satisfaction
Prazo: 2 weeks after prosthetic insertion- 1 year
questionnaire. The patient satisfaction questionnaire is composed of 14 questions concerned with esthetics, speech, mastication, operative and prosthetic procedures, incidence of complications, pre-operative instructions, total time interval, cost, operator, hygienic procedures, overall experience as well as the willingness to repeat or refer others for the procedure.
2 weeks after prosthetic insertion- 1 year

Medidas de resultados secundários

Medida de resultado
Descrição da medida
Prazo
oral health related quality of life
Prazo: 2 weeks after prosthetic insertion- 1 year
OHIP-14 scoring
2 weeks after prosthetic insertion- 1 year

Colaboradores e Investigadores

É aqui que você encontrará pessoas e organizações envolvidas com este estudo.

Investigadores

  • Investigador principal: Amira kheidr, masters, Cairo University
  • Diretor de estudo: Amr El Khadem, phd, Cairo University
  • Cadeira de estudo: Samira Ibrahim, phd, Cairo University

Datas de registro do estudo

Essas datas acompanham o progresso do registro do estudo e os envios de resumo dos resultados para ClinicalTrials.gov. Os registros do estudo e os resultados relatados são revisados ​​pela National Library of Medicine (NLM) para garantir que atendam aos padrões específicos de controle de qualidade antes de serem publicados no site público.

Datas Principais do Estudo

Início do estudo (Real)

1 de novembro de 2017

Conclusão Primária (Real)

30 de setembro de 2018

Conclusão do estudo (Real)

28 de agosto de 2019

Datas de inscrição no estudo

Enviado pela primeira vez

24 de dezembro de 2020

Enviado pela primeira vez que atendeu aos critérios de CQ

1 de janeiro de 2021

Primeira postagem (Real)

5 de janeiro de 2021

Atualizações de registro de estudo

Última Atualização Postada (Real)

10 de março de 2021

Última atualização enviada que atendeu aos critérios de controle de qualidade

8 de março de 2021

Última verificação

1 de março de 2021

Mais Informações

Termos relacionados a este estudo

Outros números de identificação do estudo

  • 151017

Plano para dados de participantes individuais (IPD)

Planeja compartilhar dados de participantes individuais (IPD)?

Não

Informações sobre medicamentos e dispositivos, documentos de estudo

Estuda um medicamento regulamentado pela FDA dos EUA

Não

Estuda um produto de dispositivo regulamentado pela FDA dos EUA

Não

Essas informações foram obtidas diretamente do site clinicaltrials.gov sem nenhuma alteração. Se você tiver alguma solicitação para alterar, remover ou atualizar os detalhes do seu estudo, entre em contato com register@clinicaltrials.gov. Assim que uma alteração for implementada em clinicaltrials.gov, ela também será atualizada automaticamente em nosso site .

Se inscrever