Evaluation of the Clinical Benefit of a Transmitter for Contralateral Routing of Signals (CROS)

2022年4月8日 更新者:Sonova AG
This study will evaluate the clinical benefit of a transmitter for contralateral routing of signals. The benefit will be evaluated in noisy environments regarding speech intelligibility when the CROS system is adjusted to different microphone settings. Additionally, data regarding overall system stability, crash reboot rate, sound quality and connectivity will be obtained over a period of time to validate the CROS system in combination with smartphone and accessories. This study is a confirmatory study.

研究概览

详细说明

Unilateral Hearing Loss (UHL) can be defined as any degree of permanent hearing loss on one ear with normal hearing in the opposite ear. Unilateral hearing loss can be debilitating associated with audiological, psychosocial and educational challenges. Audiological challenges include the reduced ability to localize sounds, reduced awareness on the unaidable side and difficulties hearing in noise or at a distance.

One solution for unaidable UHL is Contralateral Routing of Signals (CROS) and Bilateral Contralateral routing of signals (BiCROS) using a so- called CROS transmitter together with a hearing aid.

The rationale for this clinical investigation is to collect clinical data with a rechargeable CROS transmitter to evaluate the benefits of a BiCROS fitting compared to the alternative treatment option, the monaural hearing aid fitting, and to no treatment in noisy listening situations.

研究类型

介入性

注册 (实际的)

23

阶段

  • 不适用

联系人和位置

本节提供了进行研究的人员的详细联系信息,以及有关进行该研究的地点的信息。

学习地点

    • Zürich
      • Stäfa、Zürich、瑞士、8712
        • Sonova AG

参与标准

研究人员寻找符合特定描述的人,称为资格标准。这些标准的一些例子是一个人的一般健康状况或先前的治疗。

资格标准

适合学习的年龄

18年 及以上 (成人、年长者)

接受健康志愿者

不

有资格学习的性别

全部

描述

Inclusion Criteria:

  • hearing impaired adults, with & w/o hearing aids (experiences)
  • good written and spoken (Swiss) German language skills
  • ability to fill in a questionnaire conscientiously
  • informed consent as documented by signature
  • asymmetric hearing loss: one unaidable ear (min. N6 hearing loss) / the other ear with N3 or N4 hearing loss
  • availability of Smartphone
  • availability of TV or Tablet
  • ability to operate and handle the investigational device
  • ability to describe listening impressions/experiences and the use of the hearing aid
  • Ability to produce a reliable hearing test result

Exclusion Criteria:

  • Contraindications to the medical device:
  • aidable hearing loss on the intended CROS side
  • acute tinnitus (in either one ear and occurrence less than three months)
  • anatomical deformity of the CROS ear (e.g. absence of the auricle)
  • Known hypersensitivity or allergy to materials of the investigational device
  • any auricle deformities, that prevents secure placement of the (test) devices
  • no willingness to test the investigational device system
  • no willingness to test the investigational device system for at least 8h a day
  • Hint for psychological problems from investigators point of view
  • reported fluctuating hearing that could influence the test result
  • reported symptoms of vertigo and dizziness by participants

学习计划

本节提供研究计划的详细信息,包括研究的设计方式和研究的衡量标准。

研究是如何设计的?

设计细节

  • 主要用途:其他
  • 分配:不适用
  • 介入模型:单组作业
  • 屏蔽:无(打开标签)

武器和干预

参与者组/臂
干预/治疗
实验性的:Speech Intelligibility with CROS device

The focus of this study is on Speech Intelligibility (SI), evaluated by the Oldenburg Sentence test (OLSA), which measures a speech recognition threshold (SRT) in dB SNR (signal to noise ratio).

Therefore each participant will perform the tests with the experimental rechargeable CROS transmitter (CROS) in different interventions, like comparison to monaural fitting and unaided condition.

All participants will perform the same tests. The order of the intervention in the speech test is randomized, but will be performed in the same visit by each participant.

没有治疗,即参与者没有配备 CROS 设备和/或助听器。

独立条件充当控制干预。

Each participant will be fitted with the experimental CROS device on the poorer, unaidable ear and with a compatible hearing device on the other ear.

Each participant will be fitted with a hearing aid on the better hearing ear and no device on the poorer, unaidable ear.

Monaural hearing aid fitting acts as control intervention.

Each participant will be fitted with the experimental CROS device on the poorer, unaidable ear and with a compatible device on the other ear. The difference to the BiCROS condition is the setup of the microphones in the CROS device and the compatible hearing device.

This test condition is only tested for speech intelligibility in diffuse noise and acts as control intervention.

研究衡量的是什么?

主要结果指标

结果测量
措施说明
大体时间
Speech Intelligibility (SI) in noise (fix direction): BiCROS fitting vs. monaural hearing aid fitting
大体时间:2 weeks

The primary objective of this clinical investigation is to evaluate whether a BiCROS fitting (better ear fitted with a hearing device, unaidable ear supplied with a CROS device) improves speech intelligibility in noise compared to a monaural fitting (just the aidable ear is supplied by a hearing aid), for adults with an asymmetric hearing loss, measured with the Oldenburg Sentence Test (OLSA). Results of the speech test will be the SRT (speech recognition threshold) in dB SNR (signal to noise ratio).

The target speaker will be presented from 0° azimuth and is adaptive (start level at 65dB (A).

The noise will be presented on the better ear at an azimuth of 90° or 270° (depending on the site of the better ear), at a level of 70 dB (A).

2 weeks

次要结果测量

结果测量
措施说明
大体时间
SI in noise (fix direction): BiCROS fitting vs. unaided
大体时间:2 week

A secondary objective of this clinical investigation is to evaluate whether a BiCROS fitting improves speech intelligibility in noise compared to an unaided condition, for adults with an asymmetric hearing loss, measured with the Oldenburg Sentence Test (OLSA).

Results of the speech test will be the SRT (dB SNR). The target speaker will be presented from 0° azimuth and is adaptive (start level at 65dB (A).

The noise will be presented on the better ear at an azimuth of 90° or 270° (depending on the site of the better ear), at a level of 70 dB (A).

2 week
SI in diffuse noise: BiCROS fitting vs. monaural fitting
大体时间:2 weeks

A secondary objective of this clinical investigation is to evaluate whether a BiCROS fitting improves speech intelligibility by at least 1 dB SNR for 50% SRT in diffuse noise, compared to a monaural hearing aid fitting.

The target speaker will be presented from 0° azimuth and is adaptive (start level at 65dB (A).

The noise will be presented on the better ear at an azimuth of 90° or 270° (depending on the site of the better ear), at a level of 70 dB (A).

2 weeks
SI in diffuse noise: BiCROS fitting vs. unaided
大体时间:2 weeks

A secondary objective of this clinical investigation is to evaluate whether a BiCROS fitting improves speech intelligibility by at least 1 dB SNR for 50% SRT in diffuse noise, compared to an unaided condition.

The target speaker will be presented from 0° azimuth and is adaptive (start level at 65dB (A).

The noise will be presented on the better ear at an azimuth of 90° or 270° (depending on the site of the better ear), at a level of 70 dB (A).

2 weeks
SI in diffuse noise: BiCROS vs. CROS baseline fitting
大体时间:2 weeks

A secondary objective of this clinical investigation is to evaluate whether a BiCROS fitting improves speech intelligibility in diffuse noise compared with a CROS baseline fitting. CROS baseline means a fitting of an additional program with different hearing instrument microphone setup.

The SI will be tested with the OLSA in diffuse noise. The target speaker will be presented from 0° azimuth and is adaptive (start level at 65dB (A).

The noise will be presented on the better ear at an azimuth of 90° or 270° (depending on the site of the better ear), at a level of 70 dB (A).

2 weeks
SI in diffuse noise: CROS baseline fitting vs. unaided
大体时间:2 weeks

A secondary objective of this clinical investigation is to evaluate whether a CROS baseline fitting improves speech intelligibility in diffuse noise compared with an unaided condition.

The SI will be tested with the OLSA in diffuse noise. The target speaker will be presented from 0° azimuth and is adaptive (start level at 65dB (A).

The noise will be presented on the better ear at an azimuth of 90° or 270° (depending on the site of the better ear), at a level of 70 dB (A).

2 weeks
SI in diffuse noise: CROS baseline fitting vs. monaural fitting
大体时间:2 weeks

A secondary objective of this clinical investigation is to evaluate whether a CROS baseline fitting improves speech intelligibility in diffuse noise compared with a monaural fitting.

The SI will be tested with the OLSA in diffuse noise. The target speaker will be presented from 0° azimuth and is adaptive (start level at 65dB (A).

The noise will be presented on the better ear at an azimuth of 90° or 270° (depending on the site of the better ear), at a level of 70 dB (A).

2 weeks
SP in diffuse noise: monaural fitting vs. unaided
大体时间:2 weeks

A secondary objective of this clinical investigation is to evaluate whether a monaural fitting improves speech intelligibility in diffuse noise compared with an unaided condition.

The SI will be tested with the OLSA in diffuse noise. The target speaker will be presented from 0° azimuth and is adaptive (start level at 65dB (A).

The noise will be presented on the better ear at an azimuth of 90° or 270° (depending on the site of the better ear), at a level of 70 dB (A).

2 weeks
Evaluation of Sound quality
大体时间:3 weeks

A secondary objective of this study is to evaluate the participant's satisfaction of the sound quality of the experimental CROS device by a subjective rating during a three-week home trial period.

Scale: very unsatisfied- unsatisfied- neither nor- satisfied- very satisfied

3 weeks
Evaluation of System stability
大体时间:3 weeks

A secondary objective of this study is to evaluate the participant's satisfaction of the system stability of the experimental CROS device during a three-week home trial period.

The participant shall report, if there are artefacts audible: never/ 1-2 times a week/ 3-6 times a week/ daily

3 weeks
Evaluation of streaming
大体时间:3 weeks

A secondary objective of this study is to evaluate the participant's satisfaction of the streaming sound quality of the experimental CROS device, by a subjective rating during a three-week home trial period.

Scale: very unsatisfied- unsatisfied- neither nor- satisfied- very satisfied

3 weeks
Evaluation of listening effort
大体时间:3 weeks

A secondary objective is to evaluate the subjective listening effort in noise reported by the participant whilst wearing the experimental CROS device.

Scale: not at all - slightly - somewhat - moderately - very - extremely

3 weeks

合作者和调查者

在这里您可以找到参与这项研究的人员和组织。

赞助

出版物和有用的链接

负责输入研究信息的人员自愿提供这些出版物。这些可能与研究有关。

研究记录日期

这些日期跟踪向 ClinicalTrials.gov 提交研究记录和摘要结果的进度。研究记录和报告的结果由国家医学图书馆 (NLM) 审查,以确保它们在发布到公共网站之前符合特定的质量控制标准。

研究主要日期

学习开始 (实际的)

2021年10月26日

初级完成 (实际的)

2022年3月14日

研究完成 (实际的)

2022年3月14日

研究注册日期

首次提交

2021年10月22日

首先提交符合 QC 标准的

2021年10月22日

首次发布 (实际的)

2021年11月3日

研究记录更新

最后更新发布 (实际的)

2022年4月15日

上次提交的符合 QC 标准的更新

2022年4月8日

最后验证

2021年11月1日

更多信息

与本研究相关的术语

药物和器械信息、研究文件

研究美国 FDA 监管的药品

不

研究美国 FDA 监管的设备产品

不

此信息直接从 clinicaltrials.gov 网站检索,没有任何更改。如果您有任何更改、删除或更新研究详细信息的请求,请联系 register@clinicaltrials.gov. clinicaltrials.gov 上实施更改,我们的网站上也会自动更新.