此页面是自动翻译的,不保证翻译的准确性。请参阅 英文版 对于源文本。

Hearing Outcomes With the Nucleus® 8 Sound Processor and Nucleus® 7 Sound Processor in Adult Veteran and Non-veteran Cochlear Implant Recipients (SALUTE)

2026年5月6日 更新者:Cochlear

A Post-market Interventional, Prospective, Open-label, Multi-center, Clinical Investigation of Hearing Outcomes With the Nucleus 8 Sound Processor and Nucleus 7 Sound Processor in Adult Veteran and Non-veteran Cochlear Implant Recipients

The main purpose of this study is to understand how well a noise reduction feature called ForwardFocus works when used with two different sound processors: the Nucleus® 8 Sound Processor and the Nucleus® 7 Sound Processor, in adults with cochlear implants.

The study will include two groups of adult cochlear implant recipients: veterans and non-veterans. Comparing these groups will help researchers understand how these sound processors perform in veteran populations as well as the broader adult cochlear implant community.

Participants will use each sound processor and then take part in speech understanding tests in background noise. They will also complete questionnaires about their listening experiences with each processor.

研究概览

研究类型

介入性

注册 (估计的)

26

阶段

  • 不适用

联系人和位置

本节提供了进行研究的人员的详细联系信息,以及有关进行该研究的地点的信息。

学习联系方式

学习地点

    • Colorado
      • Lone Tree、Colorado、美国、80124
        • Denver Research and Technology Lab
        • 接触:
          • PRS Specialist

参与标准

研究人员寻找符合特定描述的人,称为资格标准。这些标准的一些例子是一个人的一般健康状况或先前的治疗。

资格标准

适合学习的年龄

  • 成人
  • 年长者

接受健康志愿者

不

描述

Inclusion Criteria:

  1. Aged 18 years or older, at time of consent.
  2. Implanted with the CI600 Series (CI612, CI632, CI622, CI624), CI500 Series (CI512, CI532, CI522) or Freedom Series (CI24R(CA), CI24R(ST) CI24R(CS), CI24M, CI24RE(CA), CI24RE(ST), CI422) in the test ear.
  3. At least 18 active electrodes in the test ear.
  4. At least 6 months experience with a cochlear implant in the test ear.
  5. Able to score 20% or more at +10 dB SNR with CI alone on an S0N0 sentence in-noise test in the test ear.
  6. Pure-tone average unaided threshold (500 through 4000 Hz) ≥ 30 dB HL, in the contralateral ear.
  7. Candidate is a fluent speaker in the language used to assess speech perception performance.
  8. Direct access to a compatible smartphone.
  9. Willing and able to provide written informed consent.

Exclusion Criteria:

  1. Recipients with single-sided deafness as determined by the Investigator.
  2. Additional disabilities that would prevent participation in evaluations.
  3. Unrealistic expectations on the part of the subject, regarding the possible benefits, risks and limitations that are inherent to the procedures.
  4. Unable or unwilling to comply with the requirements of the clinical investigation as determined by the Investigator.
  5. Investigator site personnel directly affiliated with this study and/or their immediate families; immediate family is defined as a spouse, parent, child, or sibling.
  6. Cochlear employees or employees of Contract Research Organizations or contractors engaged by Cochlear for the purposes of this investigation.
  7. Current participation, or participation in another interventional clinical study/trial in the past 30 days, involving an investigational drug or device (unless Cochlear sponsored and determined by Investigator or Sponsor to not impact this investigation).

学习计划

本节提供研究计划的详细信息,包括研究的设计方式和研究的衡量标准。

研究是如何设计的?

设计细节

  • 主要用途:治疗
  • 分配:随机化
  • 介入模型:交叉作业
  • 屏蔽:无(打开标签)

武器和干预

参与者组/臂
干预/治疗
实验性的:Veterans
While the user can turn ForwardFocus on from any program in the Nucleus 7 Sound Processor, for the duration of this study, SCAN will be used as the default program and ForwardFocus will be turned on for testing. This setting will be referred to as SCAN ForwardFocus (SCAN FF).
Nucleus 8 Sound Processor will be used with the SCAN 2 ForwardFocus (SCAN 2 FF) program to evaluate speech performance.
实验性的:Non-veterans
While the user can turn ForwardFocus on from any program in the Nucleus 7 Sound Processor, for the duration of this study, SCAN will be used as the default program and ForwardFocus will be turned on for testing. This setting will be referred to as SCAN ForwardFocus (SCAN FF).
Nucleus 8 Sound Processor will be used with the SCAN 2 ForwardFocus (SCAN 2 FF) program to evaluate speech performance.

研究衡量的是什么?

主要结果指标

结果测量
措施说明
大体时间
Paired difference in AzBio percent correct in noise between the Nucleus 8 Sound Processor using the SCAN 2 FF program and the Nucleus 7 Sound Processor using the SCAN FF program at a fixed signal-to-noise ratio in the S0N90 spatial configuration
大体时间:Week 2 and week 4
The AzBio sentence test is a validated test used to assess open-set sentence recognition. AzBio sentences are spoken in a conversational style with limited contextual cues that the listener can use to predict unintelligible words.
Week 2 and week 4

次要结果测量

结果测量
措施说明
大体时间
Paired difference in AzBio percent correct in noise between the Nucleus 8 Sound Processor using the SCAN 2 FF program and the Nucleus 7 Sound Processor using the SCAN FF program at a fixed signal-to-noise ratio in the S90N180 spatial configuration
大体时间:Week 2 and week 4
The AzBio sentence test is a validated test used to assess open-set sentence recognition. AzBio sentences are spoken in a conversational style with limited contextual cues that the listener can use to predict unintelligible words.
Week 2 and week 4
Paired difference in AzBio percent correct in noise between the Nucleus 8 Sound Processor using the SCAN 2 FF program and the Nucleus 7 Sound Processor using the SCAN FF program at a fixed signal-to-noise ratio in the S0N180 spatial configuration
大体时间:Week 2 and week 4
The AzBio sentence test is a validated test used to assess open-set sentence recognition. AzBio sentences are spoken in a conversational style with limited contextual cues that the listener can use to predict unintelligible words.
Week 2 and week 4
Paired difference in AzBio improvement (percentage-point change) for the Nucleus 8 Sound Processor (SCAN 2 FF minus SCAN 2) compared to the Nucleus 7 Sound Processor (SCAN FF minus SCAN) in the S0N180 spatial configuration
大体时间:Week 2 and week 4
The AzBio sentence test is a validated test used to assess open-set sentence recognition. AzBio sentences are spoken in a conversational style with limited contextual cues that the listener can use to predict unintelligible words.
Week 2 and week 4
Paired difference in CNC percent correct in quiet between the Nucleus 8 Sound Processor using the SCAN 2 FF program and the Nucleus 7 Sound Processor using the SCAN FF program in the S0 spatial configuration
大体时间:Week 2 and week 4
The consonant-nucleus-consonant (CNC) monosyllabic word test will be used to assess speech perception of words in quiet. The test consists of 10 recorded lists of 50 monosyllabic words, produced by a male talker.
Week 2 and week 4
Paired difference in AzBio percent correct in quiet between the Nucleus 8 Sound Processor using the SCAN 2 FF program and the Nucleus 7 Sound Processor using the SCAN FF program in the S0 spatial configuration
大体时间:Week 2 and week 4
The AzBio sentence test is a validated test used to assess open-set sentence recognition. AzBio sentences are spoken in a conversational style with limited contextual cues that the listener can use to predict unintelligible words.
Week 2 and week 4
Paired difference in AzBio percent correct in noise between the Nucleus 8 Sound Processor using the SCAN 2 FF program and the Nucleus 7 Sound Processor using the SCAN FF program at a fixed signal-to-noise ratio in the S0N0 spatial configuration
大体时间:Week 2 and week 4
The AzBio sentence test is a validated test used to assess open-set sentence recognition. AzBio sentences are spoken in a conversational style with limited contextual cues that the listener can use to predict unintelligible words.
Week 2 and week 4
Proportion of participants preferring each sound processor in various listening domains
大体时间:Week 4
The Device Preference Questionnaire is a custom self-assessment to evaluate participants' preference between the Nucleus 8 and Nucleus 7 Sound Processors, or "no preference".
Week 4
Mean difference in SSQ-12 total scores between the Nucleus 8 Sound Processor and the Nucleus 7 Sound Processor
大体时间:Week 2 and Week 4
The SSQ-12 is a validated 12-item abbreviated form of the Speech, Spatial, and Qualities of Hearing scale that measures self-reported hearing ability across speech, spatial, and sound quality domains, with each item rated from 0 (poor) to 10 (excellent). Total scores are calculated by averaging responses across relevant items.
Week 2 and Week 4
Mean difference in VFS-A-10 total scores between the Nucleus 8 Sound Processor and the Nucleus 7 Sound Processor
大体时间:Week 2 and Week 4
The Vanderbilt Fatigue Scale-10-Item Adult (VFS-A-10) is a validated 10-item subjective scale designed to assess listening-related fatigue in adults with hearing loss. The scale provides a total score based on all 10 questions rated on a Likert scale from 0 (no listening-related fatigue) to 4 (severe listening-related fatigue).
Week 2 and Week 4

合作者和调查者

在这里您可以找到参与这项研究的人员和组织。

赞助

研究记录日期

这些日期跟踪向 ClinicalTrials.gov 提交研究记录和摘要结果的进度。研究记录和报告的结果由国家医学图书馆 (NLM) 审查,以确保它们在发布到公共网站之前符合特定的质量控制标准。

研究主要日期

学习开始 (估计的)

2026年5月1日

初级完成 (估计的)

2026年9月1日

研究完成 (估计的)

2026年9月1日

研究注册日期

首次提交

2026年5月6日

首先提交符合 QC 标准的

2026年5月6日

首次发布 (实际的)

2026年5月12日

研究记录更新

最后更新发布 (实际的)

2026年5月12日

上次提交的符合 QC 标准的更新

2026年5月6日

最后验证

2026年4月1日

更多信息

与本研究相关的术语

计划个人参与者数据 (IPD)

计划共享个人参与者数据 (IPD)?

不

IPD 计划说明

Cochlear do not have an approved platform for public sharing of IPD collected in this study. Data may be provided to individual researchers on request.

药物和器械信息、研究文件

研究美国 FDA 监管的药品

不

研究美国 FDA 监管的设备产品

是的

此信息直接从 clinicaltrials.gov 网站检索,没有任何更改。如果您有任何更改、删除或更新研究详细信息的请求,请联系 register@clinicaltrials.gov. clinicaltrials.gov 上实施更改,我们的网站上也会自动更新.

订阅