此页面是自动翻译的,不保证翻译的准确性。请参阅 英文版 对于源文本。

High-Flow Nasal Cannula on Exercise Tolerance in Heart Failure Patients Undergoing Cardiac Rehabilitation

2026年5月30日 更新者:Manuel Gálvez Reyes、Universidad de Santiago de Chile

Effect of High-Flow Nasal Cannula Use on Exercise Tolerance and Physical Performance in Heart Failure Patients Enrolled in a Cardiac Rehabilitation Program: A Randomized Crossover Trial

The goal of this clinical trial is to learn if a high-flow nasal cannula (HFNC) - a device that delivers warm, humidified air through a small tube placed in the nostrils - can improve exercise tolerance in adults with heart failure (HF) who are entering a cardiac rehabilitation program. The main questions it aims to answer are: Can HFNC help people with heart failure exercise for a longer time during a treadmill test? and does HFNC lower how hard people feel they are working during exercise?

Researchers will compare exercise performance with HFNC to exercise performance without HFNC to see if HFNC helps people with HF tolerate exercise better. Participants will:

Complete two treadmill exercise tests, one with HFNC and one without, in a randomly assigned order.

Wait 48 to 72 hours between the two tests to allow full recovery. Have their heart rate, blood pressure, oxygen level, and breathing rate measured before and after each test.

研究概览

详细说明

Heart failure is a chronic syndrome characterized by reduced cardiac output, exercise intolerance, and dyspnea. Despite the well-established benefits of cardiac rehabilitation, many HF patients have severely limited exercise capacity, which restricts the intensity and duration of training they can safely perform.

High-flow nasal cannula (HFNC) delivers heated, humidified air at flow rates of 50-60 L/min. Its physiological effects include reduction of inspiratory work, washout of nasopharyngeal dead space, generation of positive end-expiratory pressure, and improved mucociliary transport. These mechanisms may facilitate exercise in patients with cardiorespiratory limitations.

STUDY DESIGN. Randomized crossover trial. Each participant acts as their own control, completing two incremental treadmill tests in random order, separated by a washout period of 48-72 hours: Condition A (experimental): HFNC via AIRVO 2™ device (Fisher & Paykel Healthcare) with asymmetric nasal cannula at 50-60 L/min, FiO₂ 0.21, temperature 34-37°C. Condition B (control): no ventilatory support device. Randomization will be performed using randomizer.org. Before the experimental condition, participants will undergo an acclimatization period in which flow is increased by 10 L/min every 5-10 minutes until reaching the target flow or maximum tolerated flow.

EXERCISE PROTOCOL. An incremental protocol will be used on the treadmill, which will consist of incline and a progressive increase in speed and grade. The test ends at voluntary exhaustion or when predefined safety stopping criteria are met.

SAFETY. The test will be stopped if any of the following occur: chest pain, severe dyspnea (Borg ≥8), nausea or presyncope, cyanosis, SpO₂ below 90%, or heart rate above 85% of age-predicted maximum. The testing site will be equipped with automated external defibrillator, bag-valve mask, emergency oxygen, and at least one team member certified in advanced life support. Direct transfer to the hospital emergency service is available on-site (Complejo Hospitalario San José).

OUTCOMES. Primary outcomes are maximum treadmill test duration (seconds) and perceived exertion (Modified Borg Scale, 0-10), measured immediately after each test. Secondary outcomes - blood pressure, heart rate, SpO₂, respiratory rate, and rate-pressure product - are measured at baseline and immediately post-test.

STATISTICAL ANALYSIS. Data normality will be assessed using the Shapiro-Wilk test (n<50). Paired t-test or Wilcoxon signed-rank test will be applied depending on data distribution. Sample size was calculated for a crossover design (two-tailed, α=0.05, power=80%, dz=0.8), yielding 23 participants; 28 will be recruited assuming 20% dropout.

CO-INVESTIGATORS: Monserrat Delgado Valverde, Monserrat Orellana Morales, Emily Quiñileo Riffo, and Sergio Silva Valverde (Escuala de Kinesiología, Universidad de Santiago de Chile). Claudia Román Ureta, Paulina Castro Olivares (Complejo Hospitalario San José).

SETTING. Cardiovascular rehabilitation program, Complejo Hospitalario San José, Independencia, Santiago, Chile.

研究类型

介入性

注册 (估计的)

28

阶段

  • 不适用

联系人和位置

本节提供了进行研究的人员的详细联系信息,以及有关进行该研究的地点的信息。

学习联系方式

学习地点

    • Santiago Metropolitan
      • Santiago、Santiago Metropolitan、智利、8380418

参与标准

研究人员寻找符合特定描述的人,称为资格标准。这些标准的一些例子是一个人的一般健康状况或先前的治疗。

资格标准

适合学习的年龄

  • 成人
  • 年长者

接受健康志愿者

不

描述

Inclusion Criteria:

  • Age 18 years or older
  • Medical diagnosis of heart failure (documented in clinical record or referral)
  • Electrocardiogram performed within the last 6 months
  • Functional capacity class II or III according to the New York Heart Association (NYHA) classification
  • Stable pharmacological treatment
  • Stable and controlled comorbidities
  • Available to complete two evaluation sessions
  • Able and willing to provide written informed consent

Exclusion Criteria:

  • Diagnosis of respiratory disease (chronic obstructive pulmonary disease, interstitial lung disease, or pulmonary hypertension)
  • Myocardial infarction within the past 3 months
  • Hospitalization due to heart failure within the past 4 weeks
  • Cognitive impairment or inability to follow the study protocol
  • Neuromuscular or osteoarticular conditions that limit treadmill test performance

学习计划

本节提供研究计划的详细信息,包括研究的设计方式和研究的衡量标准。

研究是如何设计的?

设计细节

  • 主要用途:基础科学
  • 分配:随机化
  • 介入模型:交叉作业
  • 屏蔽:无(打开标签)

武器和干预

参与者组/臂
干预/治疗
实验性的:HFNC (Experimental)
Participants will perform an incremental treadmill test while using high-flow nasal cannula (HFNC) via AIRVO 2™ device with a nasal cannula at 50-60 L/min, FiO₂ 0.21, and temperature set at 34-37°C according to participant comfort. An acclimatization period will be performed before the test, increasing flow by 10 L/min every 5-10 minutes until reaching the target flow.
HFNC delivered via AIRVO 2™ (Fisher & Paykel Healthcare, Auckland, New Zealand) with a nasal cannula at 50-60 L/min, FiO₂ 0.21, temperature 34-37°C. The cannula is removed immediately after the test is completed.
无干预:No HFNC (Control)
Participants will perform an incremental treadmill test without any ventilatory support device.

研究衡量的是什么?

主要结果指标

结果测量
措施说明
大体时间
Maximum treadmill test duration
大体时间:Immediately after each test session (up to 24 minutes)
Maximum time achieved by the participant during the incremental treadmill test, measured in seconds
Immediately after each test session (up to 24 minutes)
Perceived exertion
大体时间:Immediately after each test session
Participant's subjective perception of effort measured using the Modified Borg Scale (0-10), where 0 is nothing at all and 10 is extremely heavy
Immediately after each test session

次要结果测量

结果测量
措施说明
大体时间
Heart rate
大体时间:Baseline and immediately after each test session
Heart rate measured in beats per minute using pulse oximetry
Baseline and immediately after each test session
Blood pressure
大体时间:Baseline and immediately after each test session
Systolic and diastolic blood pressure measured in mmHg using a sphygmomanometer
Baseline and immediately after each test session
Oxygen saturation
大体时间:Baseline and immediately after each test session
Peripheral oxygen saturation (SpO₂) measured as a percentage using pulse oximetry
Baseline and immediately after each test session
Respiratory rate
大体时间:Baseline and immediately after each test session
Respiratory rate measured in breaths per minute using a vital signs monitor
Baseline and immediately after each test session
Rate-pressure product
大体时间:Baseline and immediately after each test session
Calculated as systolic blood pressure multiplied by heart rate (mmHg × beats/min), used as an indirect indicator of myocardial oxygen demand
Baseline and immediately after each test session

合作者和调查者

在这里您可以找到参与这项研究的人员和组织。

出版物和有用的链接

负责输入研究信息的人员自愿提供这些出版物。这些可能与研究有关。

一般刊物

研究记录日期

这些日期跟踪向 ClinicalTrials.gov 提交研究记录和摘要结果的进度。研究记录和报告的结果由国家医学图书馆 (NLM) 审查,以确保它们在发布到公共网站之前符合特定的质量控制标准。

研究主要日期

学习开始 (估计的)

2026年6月1日

初级完成 (估计的)

2026年10月1日

研究完成 (估计的)

2027年3月1日

研究注册日期

首次提交

2026年5月21日

首先提交符合 QC 标准的

2026年5月21日

首次发布 (实际的)

2026年5月29日

研究记录更新

最后更新发布 (实际的)

2026年6月2日

上次提交的符合 QC 标准的更新

2026年5月30日

最后验证

2026年5月1日

更多信息

与本研究相关的术语

计划个人参与者数据 (IPD)

计划共享个人参与者数据 (IPD)?

不

IPD 计划说明

Individual participant data will not be shared during the study period. Data will be stored on a password-protected server at Universidad de Santiago de Chile for 5 years after study completion. Only anonymized data, with no information that could identify participants, may be deposited in a public repository after the custody period ends. Any future use of the data will require a specific and separate consent process.

药物和器械信息、研究文件

研究美国 FDA 监管的药品

不

研究美国 FDA 监管的设备产品

不

此信息直接从 clinicaltrials.gov 网站检索,没有任何更改。如果您有任何更改、删除或更新研究详细信息的请求,请联系 register@clinicaltrials.gov. clinicaltrials.gov 上实施更改,我们的网站上也会自动更新.

订阅