此页面是自动翻译的,不保证翻译的准确性。请参阅 英文版 对于源文本。

Efficacy of High-Flow Humidified Oxygen (HFHO) in Apneic Oxygenation for Apnea Testing: A Comparison With Continuous Positive Airway Pressure (CPAP) (APNEAFLO2W)

2026年7月8日 更新者:Centre Hospitalier Régional d'Orléans

Efficacy of High-Flow Humidified Oxygen in Apneic Oxygenation During Apnea Testing Compared With Continuous Positive Airway Pressure: A Randomized Multicenter Crossover Trial

Brain death (BD) is characterized by a severe brain injury resulting in irreversible loss of all brain and brainstem functions, while other organs may remain viable. The diagnosis of BD is based on the presence of coma, absence of brainstem reflexes, and absence of spontaneous breathing confirmed by an apnea test. In France, the apnea test is mandatory prior to organ procurement. The apnea test aims to demonstrate that hypercapnia, a strong ventilatory stimulus, does not induce any respiratory movements.

In current practice, the apnea test is performed by disconnecting the patient from mechanical ventilation for 8-10 minutes while administering oxygen. Oxygenation strategies during apnea vary across French centers. Although the use of continuous positive airway pressure (CPAP) is recommended, a substantial proportion of tests are still performed without positive end-expiratory pressure (PEEP) effect, using either an open T-piece or an intratracheal oxygen catheter. These methods are associated with a higher risk of complications, such as hypoxemia, and potential adverse effects on organ function, which is particularly relevant in the context of organ donation.

Humidified high-flow oxygen (HHFO), delivered via a specialized device connected to the endotracheal tube, provides high flow rates (up to 60 L/min), allows precise adjustment of the fraction of inspired oxygen (FiO₂ up to 1.0), and generates a minimal PEEP effect. HHFO is routinely used in intensive care units. While its feasibility during apnea testing has been reported, its efficacy during BD diagnosis has not been well evaluated.

Preliminary observations in intensive care patients with clinical brain death suggest that HHFO can be safely used during the apnea test, allowing achievement of hypercapnia and confirmation of absence of spontaneous respiration while maintaining better oxygenation compared with conventional oxygen delivery via an open T-piece.

This study aims to evaluate the efficacy of HHFO for apneic oxygenation during the apnea test, in comparison with the recommended method using CPAP.

研究概览

详细说明

The study strategy is based on performing two consecutive apnea tests in patients with clinical brain death, conducted in a randomized order. Only patients in whom the first apnea test confirms the absence of spontaneous breathing will proceed to the second apnea test. Consistency of clinical brain death at the end of the first apnea test are defined by the absence of any respiratory movement and the presence of either an arterial partial pressure of carbon dioxide (PaCO₂) ≥ 60 mmHg or an increase in PaCO₂ > 20 mmHg compared with the PaCO₂ measured at the end of the preoxygenation period.

Each of the two apnea tests will be preceded by a standardized 15-minute preoxygenation period using assisted controlled ventilation with a tidal volume of 6mL/kg of predicted body weight.

The two consecutive apnea tests will be performed in randomized order under CPAP and under HHFO with standardized parameters.

As per routine clinical practice, an arterial blood gas sample will be obtained before disconnection from the ventilator at the end of the preoxygenation period to confirm normocapnia, defined as 35 mmHg ≤ PaCO₂ ≤ 45 mmHg. A second arterial blood gas sample will be obtained at the end of the apnea test, prior to reconnection to the ventilator, to measure PaCO₂ and arterial partial pressure of oxygen (PaO₂).

Specifically for the purposes of the study, during each apnea test, the investigator will perform arterial blood gas sampling every 2 minutes to measure PaO₂, PaCO₂, and pH. At the same time points, arterial blood pressure, heart rate, pulse oximetry, and catecholamine infusion doses will be recorded.

In addition to these measurements required to meet the study objectives, demographic and clinical data will be collected primarily from the medical records to characterize the study population.

研究类型

介入性

注册 (估计的)

28

阶段

  • 不适用

联系人和位置

本节提供了进行研究的人员的详细联系信息,以及有关进行该研究的地点的信息。

学习地点

参与标准

研究人员寻找符合特定描述的人,称为资格标准。这些标准的一些例子是一个人的一般健康状况或先前的治疗。

资格标准

适合学习的年龄

  • 成人
  • 年长者

接受健康志愿者

不

描述

Inclusion Criteria:

  • Adult intensive care unit patients
  • fulfilling all criteria for clinical brain death, for whom confirmation of the absence of spontaneous breathing requires performance of an apnea test
  • And for whom consent to participate in the study was sought from a trusted person or a family member

Exclusion Criteria:

  • History of chronic obstructive pulmonary disease (COPD) classified as GOLD stage III or IV.
  • Current extracorporeal life support, including veno-arterial (VA) or veno-venous (VV) extracorporeal membrane oxygenation (ECMO).
  • PaO₂/FiO₂ ratio ≤ 150 on the most recent arterial blood gas analysis, obtained within 24 hours prior to the screening visit.
  • Presence of at least one clear or absolute contraindication to the procurement of at least one organ.
  • Presence of a high cervical spinal cord injury.
  • Patient in the prone position and/or with a contraindication to placement in the supine position at 30°.
  • Minor patient.
  • Protected adult under legal guardianship or curatorship.
  • Individual under judicial protection (safeguard of justice).
  • Individuals deprived of liberty.
  • Individual not covered by a social security or health insurance system.
  • Pregnant or breastfeeding woman.

学习计划

本节提供研究计划的详细信息,包括研究的设计方式和研究的衡量标准。

研究是如何设计的?

设计细节

  • 主要用途:其他
  • 分配:随机化
  • 介入模型:交叉作业
  • 屏蔽:无(打开标签)

武器和干预

参与者组/臂
干预/治疗
实验性的:Arm HHFO in first
HHFO in first: in this arm, the first of the two consecutive apnea tests is performed under HHFO, followed by a second apnea test under CPAP.
For each 10-minute apnea test, regardless of the oxygenation device used, arterial blood gas will be analysed and heart rate, arterial pressure, and pulse oximetry will be recorded in 2-minute intervals.
For each 10-minute apnea test, regardless of the oxygenation device used, arterial blood gas will be analysed and heart rate, arterial pressure, and pulse oximetry will be recorded in 2-minute intervals.
实验性的:Arm CPAP in first.
CPAP in first: in this arm, the first of the two consecutive apnea tests is performed under CPAP, followed by a second apnea test under HHFO.
For each 10-minute apnea test, regardless of the oxygenation device used, arterial blood gas will be analysed and heart rate, arterial pressure, and pulse oximetry will be recorded in 2-minute intervals.
For each 10-minute apnea test, regardless of the oxygenation device used, arterial blood gas will be analysed and heart rate, arterial pressure, and pulse oximetry will be recorded in 2-minute intervals.

研究衡量的是什么?

主要结果指标

结果测量
措施说明
大体时间
Change in PaO₂ (mmHg) between the beginning and the end of an apnea test under HHFO and CPAP
大体时间:From ventilator disconnection to 10th minute of the apnea test
To demonstrate the non-inferiority of humidified high-flow oxygen compared to continuous positive airway pressure in apneic oxygenation for apnea testing.
From ventilator disconnection to 10th minute of the apnea test

次要结果测量

结果测量
措施说明
大体时间
Evolution of arterial blood PaO2 parameters during the apnea test under HHFO and the apnea test with CPAP
大体时间:At 2-minute intervals from ventilator disconnection to the 10th minute of each apnea test
Recording of PaO2 values measured in 2-minute intervals during the apnea test under HHFO and apnea test with CPAP
At 2-minute intervals from ventilator disconnection to the 10th minute of each apnea test
Evolution of arterial blood PaCO2 parameters during the apnea test under HHFO and the apnea test with CPAP
大体时间:At 2-minute intervals from ventilator disconnection to the 10th minute of each apnea test
Recording of PaCO2 values measured in 2-minute intervals during the apnea test under HHFO and apnea test with CPAP
At 2-minute intervals from ventilator disconnection to the 10th minute of each apnea test
Evolution of arterial blood pH parameters during the apnea test under HHFO and the apnea test with CPAP
大体时间:At 2-minute intervals from ventilator disconnection to the 10th minute of each apnea test
Recording of pH values measured in 2-minute intervals during the apnea test under HHFO and apnea test with CPAP
At 2-minute intervals from ventilator disconnection to the 10th minute of each apnea test
Evolution of arterial blood pressure during the apnea test under HHFO and the apnea test with CPAP
大体时间:At 2-minute intervals from ventilator disconnection to the 10th minute of each apnea test
Recording of arterial blood pressure measured in 2-minute intervals during the apnea test under HHFO and with CPAP.
At 2-minute intervals from ventilator disconnection to the 10th minute of each apnea test
Evolution of heart rate during the apnea test under HHFO and the apnea test with CPAP
大体时间:At 2-minute intervals from ventilator disconnection to the 10th minute of each apnea test
Recording of heart rate measured in 2-minute intervals during the apnea test under HHFO and with CPAP.
At 2-minute intervals from ventilator disconnection to the 10th minute of each apnea test
Evolution of pulse oximetry during the apnea test under HHFO and the apnea test with CPAP
大体时间:At 2-minute intervals from ventilator disconnection to the 10th minute of each apnea test
Recording of pulse oximetry measured in 2-minute intervals during the apnea test under HHFO and with CPAP.
At 2-minute intervals from ventilator disconnection to the 10th minute of each apnea test
Time required to reach the hypercapnia thresholds necessary to confirm brain death during an apnea test under HHFO and with CPAP
大体时间:From ventilator disconnection until the hypercapnia threshold is reached
Time required to exceed 60mmHg of PaCO2 or for which PaCO2 increases by more than 20mmHg compared to the PaCO2 before disconnection during an apnea test under HHFO and with CPAP
From ventilator disconnection until the hypercapnia threshold is reached
Occurrence of apnea test interruptions during HHFO and CPAP.
大体时间:From ventilator disconnection until apnea test termination due to intolerance
Documentation of apnea test interruptions under HHFO and CPAP.
From ventilator disconnection until apnea test termination due to intolerance
Nurse-rated numeric scale evaluations of Humidified High Flow Oxygen and Continuous Positive Airway Pressure use for each enrolled patient
大体时间:Within 1 hour after each apnea test.
Nurse-rated ease of use will be assessed using a 4-point numeric scale (range: 0-3). The minimum score is 0 and the maximum score is 3. A score of 0 corresponds to very difficult use, and a score of 3 corresponds to very easy use. Higher scores indicate greater ease of use
Within 1 hour after each apnea test.

合作者和调查者

在这里您可以找到参与这项研究的人员和组织。

研究记录日期

这些日期跟踪向 ClinicalTrials.gov 提交研究记录和摘要结果的进度。研究记录和报告的结果由国家医学图书馆 (NLM) 审查,以确保它们在发布到公共网站之前符合特定的质量控制标准。

研究主要日期

学习开始 (估计的)

2026年9月15日

初级完成 (估计的)

2028年9月15日

研究完成 (估计的)

2028年9月15日

研究注册日期

首次提交

2026年6月5日

首先提交符合 QC 标准的

2026年6月5日

首次发布 (实际的)

2026年6月10日

研究记录更新

最后更新发布 (实际的)

2026年7月10日

上次提交的符合 QC 标准的更新

2026年7月8日

最后验证

2026年7月1日

更多信息

与本研究相关的术语

药物和器械信息、研究文件

研究美国 FDA 监管的药品

不

研究美国 FDA 监管的设备产品

不

此信息直接从 clinicaltrials.gov 网站检索,没有任何更改。如果您有任何更改、删除或更新研究详细信息的请求,请联系 register@clinicaltrials.gov. clinicaltrials.gov 上实施更改,我们的网站上也会自动更新.

订阅