Cette page a été traduite automatiquement et l'exactitude de la traduction n'est pas garantie. Veuillez vous référer au version anglaise pour un texte source.

Efficacy of High-Flow Humidified Oxygen (HFHO) in Apneic Oxygenation for Apnea Testing: A Comparison With Continuous Positive Airway Pressure (CPAP) (APNEAFLO2W)

8 juillet 2026 mis à jour par: Centre Hospitalier Régional d'Orléans

Efficacy of High-Flow Humidified Oxygen in Apneic Oxygenation During Apnea Testing Compared With Continuous Positive Airway Pressure: A Randomized Multicenter Crossover Trial

Brain death (BD) is characterized by a severe brain injury resulting in irreversible loss of all brain and brainstem functions, while other organs may remain viable. The diagnosis of BD is based on the presence of coma, absence of brainstem reflexes, and absence of spontaneous breathing confirmed by an apnea test. In France, the apnea test is mandatory prior to organ procurement. The apnea test aims to demonstrate that hypercapnia, a strong ventilatory stimulus, does not induce any respiratory movements.

In current practice, the apnea test is performed by disconnecting the patient from mechanical ventilation for 8-10 minutes while administering oxygen. Oxygenation strategies during apnea vary across French centers. Although the use of continuous positive airway pressure (CPAP) is recommended, a substantial proportion of tests are still performed without positive end-expiratory pressure (PEEP) effect, using either an open T-piece or an intratracheal oxygen catheter. These methods are associated with a higher risk of complications, such as hypoxemia, and potential adverse effects on organ function, which is particularly relevant in the context of organ donation.

Humidified high-flow oxygen (HHFO), delivered via a specialized device connected to the endotracheal tube, provides high flow rates (up to 60 L/min), allows precise adjustment of the fraction of inspired oxygen (FiO₂ up to 1.0), and generates a minimal PEEP effect. HHFO is routinely used in intensive care units. While its feasibility during apnea testing has been reported, its efficacy during BD diagnosis has not been well evaluated.

Preliminary observations in intensive care patients with clinical brain death suggest that HHFO can be safely used during the apnea test, allowing achievement of hypercapnia and confirmation of absence of spontaneous respiration while maintaining better oxygenation compared with conventional oxygen delivery via an open T-piece.

This study aims to evaluate the efficacy of HHFO for apneic oxygenation during the apnea test, in comparison with the recommended method using CPAP.

Aperçu de l'étude

Description détaillée

The study strategy is based on performing two consecutive apnea tests in patients with clinical brain death, conducted in a randomized order. Only patients in whom the first apnea test confirms the absence of spontaneous breathing will proceed to the second apnea test. Consistency of clinical brain death at the end of the first apnea test are defined by the absence of any respiratory movement and the presence of either an arterial partial pressure of carbon dioxide (PaCO₂) ≥ 60 mmHg or an increase in PaCO₂ > 20 mmHg compared with the PaCO₂ measured at the end of the preoxygenation period.

Each of the two apnea tests will be preceded by a standardized 15-minute preoxygenation period using assisted controlled ventilation with a tidal volume of 6mL/kg of predicted body weight.

The two consecutive apnea tests will be performed in randomized order under CPAP and under HHFO with standardized parameters.

As per routine clinical practice, an arterial blood gas sample will be obtained before disconnection from the ventilator at the end of the preoxygenation period to confirm normocapnia, defined as 35 mmHg ≤ PaCO₂ ≤ 45 mmHg. A second arterial blood gas sample will be obtained at the end of the apnea test, prior to reconnection to the ventilator, to measure PaCO₂ and arterial partial pressure of oxygen (PaO₂).

Specifically for the purposes of the study, during each apnea test, the investigator will perform arterial blood gas sampling every 2 minutes to measure PaO₂, PaCO₂, and pH. At the same time points, arterial blood pressure, heart rate, pulse oximetry, and catecholamine infusion doses will be recorded.

In addition to these measurements required to meet the study objectives, demographic and clinical data will be collected primarily from the medical records to characterize the study population.

Type d'étude

Interventionnel

Inscription (Estimé)

28

Phase

  • N'est pas applicable

Contacts et emplacements

Cette section fournit les coordonnées de ceux qui mènent l'étude et des informations sur le lieu où cette étude est menée.

Lieux d'étude

Critères de participation

Les chercheurs recherchent des personnes qui correspondent à une certaine description, appelée critères d'éligibilité. Certains exemples de ces critères sont l'état de santé général d'une personne ou des traitements antérieurs.

Critère d'éligibilité

Âges éligibles pour étudier

  • Adulte
  • Adulte plus âgé

Accepte les volontaires sains

Non

La description

Inclusion Criteria:

  • Adult intensive care unit patients
  • fulfilling all criteria for clinical brain death, for whom confirmation of the absence of spontaneous breathing requires performance of an apnea test
  • And for whom consent to participate in the study was sought from a trusted person or a family member

Exclusion Criteria:

  • History of chronic obstructive pulmonary disease (COPD) classified as GOLD stage III or IV.
  • Current extracorporeal life support, including veno-arterial (VA) or veno-venous (VV) extracorporeal membrane oxygenation (ECMO).
  • PaO₂/FiO₂ ratio ≤ 150 on the most recent arterial blood gas analysis, obtained within 24 hours prior to the screening visit.
  • Presence of at least one clear or absolute contraindication to the procurement of at least one organ.
  • Presence of a high cervical spinal cord injury.
  • Patient in the prone position and/or with a contraindication to placement in the supine position at 30°.
  • Minor patient.
  • Protected adult under legal guardianship or curatorship.
  • Individual under judicial protection (safeguard of justice).
  • Individuals deprived of liberty.
  • Individual not covered by a social security or health insurance system.
  • Pregnant or breastfeeding woman.

Plan d'étude

Cette section fournit des détails sur le plan d'étude, y compris la façon dont l'étude est conçue et ce que l'étude mesure.

Comment l'étude est-elle conçue ?

Détails de conception

  • Objectif principal: Autre
  • Répartition: Randomisé
  • Modèle interventionnel: Affectation croisée
  • Masquage: Aucun (étiquette ouverte)

Armes et Interventions

Groupe de participants / Bras
Intervention / Traitement
Expérimental: Arm HHFO in first
HHFO in first: in this arm, the first of the two consecutive apnea tests is performed under HHFO, followed by a second apnea test under CPAP.
For each 10-minute apnea test, regardless of the oxygenation device used, arterial blood gas will be analysed and heart rate, arterial pressure, and pulse oximetry will be recorded in 2-minute intervals.
For each 10-minute apnea test, regardless of the oxygenation device used, arterial blood gas will be analysed and heart rate, arterial pressure, and pulse oximetry will be recorded in 2-minute intervals.
Expérimental: Arm CPAP in first.
CPAP in first: in this arm, the first of the two consecutive apnea tests is performed under CPAP, followed by a second apnea test under HHFO.
For each 10-minute apnea test, regardless of the oxygenation device used, arterial blood gas will be analysed and heart rate, arterial pressure, and pulse oximetry will be recorded in 2-minute intervals.
For each 10-minute apnea test, regardless of the oxygenation device used, arterial blood gas will be analysed and heart rate, arterial pressure, and pulse oximetry will be recorded in 2-minute intervals.

Que mesure l'étude ?

Principaux critères de jugement

Mesure des résultats
Description de la mesure
Délai
Change in PaO₂ (mmHg) between the beginning and the end of an apnea test under HHFO and CPAP
Délai: From ventilator disconnection to 10th minute of the apnea test
To demonstrate the non-inferiority of humidified high-flow oxygen compared to continuous positive airway pressure in apneic oxygenation for apnea testing.
From ventilator disconnection to 10th minute of the apnea test

Mesures de résultats secondaires

Mesure des résultats
Description de la mesure
Délai
Evolution of arterial blood PaO2 parameters during the apnea test under HHFO and the apnea test with CPAP
Délai: At 2-minute intervals from ventilator disconnection to the 10th minute of each apnea test
Recording of PaO2 values measured in 2-minute intervals during the apnea test under HHFO and apnea test with CPAP
At 2-minute intervals from ventilator disconnection to the 10th minute of each apnea test
Evolution of arterial blood PaCO2 parameters during the apnea test under HHFO and the apnea test with CPAP
Délai: At 2-minute intervals from ventilator disconnection to the 10th minute of each apnea test
Recording of PaCO2 values measured in 2-minute intervals during the apnea test under HHFO and apnea test with CPAP
At 2-minute intervals from ventilator disconnection to the 10th minute of each apnea test
Evolution of arterial blood pH parameters during the apnea test under HHFO and the apnea test with CPAP
Délai: At 2-minute intervals from ventilator disconnection to the 10th minute of each apnea test
Recording of pH values measured in 2-minute intervals during the apnea test under HHFO and apnea test with CPAP
At 2-minute intervals from ventilator disconnection to the 10th minute of each apnea test
Evolution of arterial blood pressure during the apnea test under HHFO and the apnea test with CPAP
Délai: At 2-minute intervals from ventilator disconnection to the 10th minute of each apnea test
Recording of arterial blood pressure measured in 2-minute intervals during the apnea test under HHFO and with CPAP.
At 2-minute intervals from ventilator disconnection to the 10th minute of each apnea test
Evolution of heart rate during the apnea test under HHFO and the apnea test with CPAP
Délai: At 2-minute intervals from ventilator disconnection to the 10th minute of each apnea test
Recording of heart rate measured in 2-minute intervals during the apnea test under HHFO and with CPAP.
At 2-minute intervals from ventilator disconnection to the 10th minute of each apnea test
Evolution of pulse oximetry during the apnea test under HHFO and the apnea test with CPAP
Délai: At 2-minute intervals from ventilator disconnection to the 10th minute of each apnea test
Recording of pulse oximetry measured in 2-minute intervals during the apnea test under HHFO and with CPAP.
At 2-minute intervals from ventilator disconnection to the 10th minute of each apnea test
Time required to reach the hypercapnia thresholds necessary to confirm brain death during an apnea test under HHFO and with CPAP
Délai: From ventilator disconnection until the hypercapnia threshold is reached
Time required to exceed 60mmHg of PaCO2 or for which PaCO2 increases by more than 20mmHg compared to the PaCO2 before disconnection during an apnea test under HHFO and with CPAP
From ventilator disconnection until the hypercapnia threshold is reached
Occurrence of apnea test interruptions during HHFO and CPAP.
Délai: From ventilator disconnection until apnea test termination due to intolerance
Documentation of apnea test interruptions under HHFO and CPAP.
From ventilator disconnection until apnea test termination due to intolerance
Nurse-rated numeric scale evaluations of Humidified High Flow Oxygen and Continuous Positive Airway Pressure use for each enrolled patient
Délai: Within 1 hour after each apnea test.
Nurse-rated ease of use will be assessed using a 4-point numeric scale (range: 0-3). The minimum score is 0 and the maximum score is 3. A score of 0 corresponds to very difficult use, and a score of 3 corresponds to very easy use. Higher scores indicate greater ease of use
Within 1 hour after each apnea test.

Collaborateurs et enquêteurs

C'est ici que vous trouverez les personnes et les organisations impliquées dans cette étude.

Dates d'enregistrement des études

Ces dates suivent la progression des dossiers d'étude et des soumissions de résultats sommaires à ClinicalTrials.gov. Les dossiers d'étude et les résultats rapportés sont examinés par la Bibliothèque nationale de médecine (NLM) pour s'assurer qu'ils répondent à des normes de contrôle de qualité spécifiques avant d'être publiés sur le site Web public.

Dates principales de l'étude

Début de l'étude (Estimé)

15 septembre 2026

Achèvement primaire (Estimé)

15 septembre 2028

Achèvement de l'étude (Estimé)

15 septembre 2028

Dates d'inscription aux études

Première soumission

5 juin 2026

Première soumission répondant aux critères de contrôle qualité

5 juin 2026

Première publication (Réel)

10 juin 2026

Mises à jour des dossiers d'étude

Dernière mise à jour publiée (Réel)

10 juillet 2026

Dernière mise à jour soumise répondant aux critères de contrôle qualité

8 juillet 2026

Dernière vérification

1 juillet 2026

Plus d'information

Termes liés à cette étude

Informations sur les médicaments et les dispositifs, documents d'étude

Étudie un produit pharmaceutique réglementé par la FDA américaine

Non

Étudie un produit d'appareil réglementé par la FDA américaine

Non

Ces informations ont été extraites directement du site Web clinicaltrials.gov sans aucune modification. Si vous avez des demandes de modification, de suppression ou de mise à jour des détails de votre étude, veuillez contacter register@clinicaltrials.gov. Dès qu'un changement est mis en œuvre sur clinicaltrials.gov, il sera également mis à jour automatiquement sur notre site Web .

S'abonner