Esta página foi traduzida automaticamente e a precisão da tradução não é garantida. Por favor, consulte o versão em inglês para um texto fonte.

Efficacy of High-Flow Humidified Oxygen (HFHO) in Apneic Oxygenation for Apnea Testing: A Comparison With Continuous Positive Airway Pressure (CPAP) (APNEAFLO2W)

8 de julho de 2026 atualizado por: Centre Hospitalier Régional d'Orléans

Efficacy of High-Flow Humidified Oxygen in Apneic Oxygenation During Apnea Testing Compared With Continuous Positive Airway Pressure: A Randomized Multicenter Crossover Trial

Brain death (BD) is characterized by a severe brain injury resulting in irreversible loss of all brain and brainstem functions, while other organs may remain viable. The diagnosis of BD is based on the presence of coma, absence of brainstem reflexes, and absence of spontaneous breathing confirmed by an apnea test. In France, the apnea test is mandatory prior to organ procurement. The apnea test aims to demonstrate that hypercapnia, a strong ventilatory stimulus, does not induce any respiratory movements.

In current practice, the apnea test is performed by disconnecting the patient from mechanical ventilation for 8-10 minutes while administering oxygen. Oxygenation strategies during apnea vary across French centers. Although the use of continuous positive airway pressure (CPAP) is recommended, a substantial proportion of tests are still performed without positive end-expiratory pressure (PEEP) effect, using either an open T-piece or an intratracheal oxygen catheter. These methods are associated with a higher risk of complications, such as hypoxemia, and potential adverse effects on organ function, which is particularly relevant in the context of organ donation.

Humidified high-flow oxygen (HHFO), delivered via a specialized device connected to the endotracheal tube, provides high flow rates (up to 60 L/min), allows precise adjustment of the fraction of inspired oxygen (FiO₂ up to 1.0), and generates a minimal PEEP effect. HHFO is routinely used in intensive care units. While its feasibility during apnea testing has been reported, its efficacy during BD diagnosis has not been well evaluated.

Preliminary observations in intensive care patients with clinical brain death suggest that HHFO can be safely used during the apnea test, allowing achievement of hypercapnia and confirmation of absence of spontaneous respiration while maintaining better oxygenation compared with conventional oxygen delivery via an open T-piece.

This study aims to evaluate the efficacy of HHFO for apneic oxygenation during the apnea test, in comparison with the recommended method using CPAP.

Visão geral do estudo

Descrição detalhada

The study strategy is based on performing two consecutive apnea tests in patients with clinical brain death, conducted in a randomized order. Only patients in whom the first apnea test confirms the absence of spontaneous breathing will proceed to the second apnea test. Consistency of clinical brain death at the end of the first apnea test are defined by the absence of any respiratory movement and the presence of either an arterial partial pressure of carbon dioxide (PaCO₂) ≥ 60 mmHg or an increase in PaCO₂ > 20 mmHg compared with the PaCO₂ measured at the end of the preoxygenation period.

Each of the two apnea tests will be preceded by a standardized 15-minute preoxygenation period using assisted controlled ventilation with a tidal volume of 6mL/kg of predicted body weight.

The two consecutive apnea tests will be performed in randomized order under CPAP and under HHFO with standardized parameters.

As per routine clinical practice, an arterial blood gas sample will be obtained before disconnection from the ventilator at the end of the preoxygenation period to confirm normocapnia, defined as 35 mmHg ≤ PaCO₂ ≤ 45 mmHg. A second arterial blood gas sample will be obtained at the end of the apnea test, prior to reconnection to the ventilator, to measure PaCO₂ and arterial partial pressure of oxygen (PaO₂).

Specifically for the purposes of the study, during each apnea test, the investigator will perform arterial blood gas sampling every 2 minutes to measure PaO₂, PaCO₂, and pH. At the same time points, arterial blood pressure, heart rate, pulse oximetry, and catecholamine infusion doses will be recorded.

In addition to these measurements required to meet the study objectives, demographic and clinical data will be collected primarily from the medical records to characterize the study population.

Tipo de estudo

Intervencional

Inscrição (Estimado)

28

Estágio

  • Não aplicável

Contactos e Locais

Esta seção fornece os detalhes de contato para aqueles que conduzem o estudo e informações sobre onde este estudo está sendo realizado.

Locais de estudo

Critérios de participação

Os pesquisadores procuram pessoas que se encaixem em uma determinada descrição, chamada de critérios de elegibilidade. Alguns exemplos desses critérios são a condição geral de saúde de uma pessoa ou tratamentos anteriores.

Critérios de elegibilidade

Idades elegíveis para estudo

  • Adulto
  • Adulto mais velho

Aceita Voluntários Saudáveis

Não

Descrição

Inclusion Criteria:

  • Adult intensive care unit patients
  • fulfilling all criteria for clinical brain death, for whom confirmation of the absence of spontaneous breathing requires performance of an apnea test
  • And for whom consent to participate in the study was sought from a trusted person or a family member

Exclusion Criteria:

  • History of chronic obstructive pulmonary disease (COPD) classified as GOLD stage III or IV.
  • Current extracorporeal life support, including veno-arterial (VA) or veno-venous (VV) extracorporeal membrane oxygenation (ECMO).
  • PaO₂/FiO₂ ratio ≤ 150 on the most recent arterial blood gas analysis, obtained within 24 hours prior to the screening visit.
  • Presence of at least one clear or absolute contraindication to the procurement of at least one organ.
  • Presence of a high cervical spinal cord injury.
  • Patient in the prone position and/or with a contraindication to placement in the supine position at 30°.
  • Minor patient.
  • Protected adult under legal guardianship or curatorship.
  • Individual under judicial protection (safeguard of justice).
  • Individuals deprived of liberty.
  • Individual not covered by a social security or health insurance system.
  • Pregnant or breastfeeding woman.

Plano de estudo

Esta seção fornece detalhes do plano de estudo, incluindo como o estudo é projetado e o que o estudo está medindo.

Como o estudo é projetado?

Detalhes do projeto

  • Finalidade Principal: Outro
  • Alocação: Randomizado
  • Modelo Intervencional: Atribuição cruzada
  • Mascaramento: Nenhum (rótulo aberto)

Armas e Intervenções

Grupo de Participantes / Braço
Intervenção / Tratamento
Experimental: Arm HHFO in first
HHFO in first: in this arm, the first of the two consecutive apnea tests is performed under HHFO, followed by a second apnea test under CPAP.
For each 10-minute apnea test, regardless of the oxygenation device used, arterial blood gas will be analysed and heart rate, arterial pressure, and pulse oximetry will be recorded in 2-minute intervals.
For each 10-minute apnea test, regardless of the oxygenation device used, arterial blood gas will be analysed and heart rate, arterial pressure, and pulse oximetry will be recorded in 2-minute intervals.
Experimental: Arm CPAP in first.
CPAP in first: in this arm, the first of the two consecutive apnea tests is performed under CPAP, followed by a second apnea test under HHFO.
For each 10-minute apnea test, regardless of the oxygenation device used, arterial blood gas will be analysed and heart rate, arterial pressure, and pulse oximetry will be recorded in 2-minute intervals.
For each 10-minute apnea test, regardless of the oxygenation device used, arterial blood gas will be analysed and heart rate, arterial pressure, and pulse oximetry will be recorded in 2-minute intervals.

O que o estudo está medindo?

Medidas de resultados primários

Medida de resultado
Descrição da medida
Prazo
Change in PaO₂ (mmHg) between the beginning and the end of an apnea test under HHFO and CPAP
Prazo: From ventilator disconnection to 10th minute of the apnea test
To demonstrate the non-inferiority of humidified high-flow oxygen compared to continuous positive airway pressure in apneic oxygenation for apnea testing.
From ventilator disconnection to 10th minute of the apnea test

Medidas de resultados secundários

Medida de resultado
Descrição da medida
Prazo
Evolution of arterial blood PaO2 parameters during the apnea test under HHFO and the apnea test with CPAP
Prazo: At 2-minute intervals from ventilator disconnection to the 10th minute of each apnea test
Recording of PaO2 values measured in 2-minute intervals during the apnea test under HHFO and apnea test with CPAP
At 2-minute intervals from ventilator disconnection to the 10th minute of each apnea test
Evolution of arterial blood PaCO2 parameters during the apnea test under HHFO and the apnea test with CPAP
Prazo: At 2-minute intervals from ventilator disconnection to the 10th minute of each apnea test
Recording of PaCO2 values measured in 2-minute intervals during the apnea test under HHFO and apnea test with CPAP
At 2-minute intervals from ventilator disconnection to the 10th minute of each apnea test
Evolution of arterial blood pH parameters during the apnea test under HHFO and the apnea test with CPAP
Prazo: At 2-minute intervals from ventilator disconnection to the 10th minute of each apnea test
Recording of pH values measured in 2-minute intervals during the apnea test under HHFO and apnea test with CPAP
At 2-minute intervals from ventilator disconnection to the 10th minute of each apnea test
Evolution of arterial blood pressure during the apnea test under HHFO and the apnea test with CPAP
Prazo: At 2-minute intervals from ventilator disconnection to the 10th minute of each apnea test
Recording of arterial blood pressure measured in 2-minute intervals during the apnea test under HHFO and with CPAP.
At 2-minute intervals from ventilator disconnection to the 10th minute of each apnea test
Evolution of heart rate during the apnea test under HHFO and the apnea test with CPAP
Prazo: At 2-minute intervals from ventilator disconnection to the 10th minute of each apnea test
Recording of heart rate measured in 2-minute intervals during the apnea test under HHFO and with CPAP.
At 2-minute intervals from ventilator disconnection to the 10th minute of each apnea test
Evolution of pulse oximetry during the apnea test under HHFO and the apnea test with CPAP
Prazo: At 2-minute intervals from ventilator disconnection to the 10th minute of each apnea test
Recording of pulse oximetry measured in 2-minute intervals during the apnea test under HHFO and with CPAP.
At 2-minute intervals from ventilator disconnection to the 10th minute of each apnea test
Time required to reach the hypercapnia thresholds necessary to confirm brain death during an apnea test under HHFO and with CPAP
Prazo: From ventilator disconnection until the hypercapnia threshold is reached
Time required to exceed 60mmHg of PaCO2 or for which PaCO2 increases by more than 20mmHg compared to the PaCO2 before disconnection during an apnea test under HHFO and with CPAP
From ventilator disconnection until the hypercapnia threshold is reached
Occurrence of apnea test interruptions during HHFO and CPAP.
Prazo: From ventilator disconnection until apnea test termination due to intolerance
Documentation of apnea test interruptions under HHFO and CPAP.
From ventilator disconnection until apnea test termination due to intolerance
Nurse-rated numeric scale evaluations of Humidified High Flow Oxygen and Continuous Positive Airway Pressure use for each enrolled patient
Prazo: Within 1 hour after each apnea test.
Nurse-rated ease of use will be assessed using a 4-point numeric scale (range: 0-3). The minimum score is 0 and the maximum score is 3. A score of 0 corresponds to very difficult use, and a score of 3 corresponds to very easy use. Higher scores indicate greater ease of use
Within 1 hour after each apnea test.

Colaboradores e Investigadores

É aqui que você encontrará pessoas e organizações envolvidas com este estudo.

Datas de registro do estudo

Essas datas acompanham o progresso do registro do estudo e os envios de resumo dos resultados para ClinicalTrials.gov. Os registros do estudo e os resultados relatados são revisados ​​pela National Library of Medicine (NLM) para garantir que atendam aos padrões específicos de controle de qualidade antes de serem publicados no site público.

Datas Principais do Estudo

Início do estudo (Estimado)

15 de setembro de 2026

Conclusão Primária (Estimado)

15 de setembro de 2028

Conclusão do estudo (Estimado)

15 de setembro de 2028

Datas de inscrição no estudo

Enviado pela primeira vez

5 de junho de 2026

Enviado pela primeira vez que atendeu aos critérios de CQ

5 de junho de 2026

Primeira postagem (Real)

10 de junho de 2026

Atualizações de registro de estudo

Última Atualização Postada (Real)

10 de julho de 2026

Última atualização enviada que atendeu aos critérios de controle de qualidade

8 de julho de 2026

Última verificação

1 de julho de 2026

Mais Informações

Termos relacionados a este estudo

Informações sobre medicamentos e dispositivos, documentos de estudo

Estuda um medicamento regulamentado pela FDA dos EUA

Não

Estuda um produto de dispositivo regulamentado pela FDA dos EUA

Não

Essas informações foram obtidas diretamente do site clinicaltrials.gov sem nenhuma alteração. Se você tiver alguma solicitação para alterar, remover ou atualizar os detalhes do seu estudo, entre em contato com register@clinicaltrials.gov. Assim que uma alteração for implementada em clinicaltrials.gov, ela também será atualizada automaticamente em nosso site .

Se inscrever