此页面是自动翻译的,不保证翻译的准确性。请参阅 英文版 对于源文本。

Comparative Evaluation of Contrast-Enhanced MRI and FDG-PET/CT in Spinal Pathology: Image Quality and Short-Term Renal-Hematologic Safety

2026年6月5日 更新者:Ahmed Elgendi、Cairo University

This prospective comparative observational study evaluates image quality characteristics and short-term physiological effects associated with contrast-enhanced magnetic resonance imaging (MRI) and fluorodeoxyglucose positron emission tomography/computed tomography (FDG-PET/CT) in patients with cervical and lumbar spinal pathologies.

A total of 120 adult participants undergo either contrast-enhanced MRI or FDG-PET/CT as part of routine clinical evaluation. Image quality is assessed using quantitative metrics, including signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR), as well as qualitative Visual Grading Analysis (VGA) performed by blinded radiologists. Short-term physiological effects are evaluated using blood urea nitrogen (BUN), estimated glomerular filtration rate (eGFR), and hemoglobin measurements obtained before imaging and 48 hours after imaging.

The study aims to compare image quality characteristics and short-term physiological parameters associated with these imaging modalities and to examine the influence of age group and spinal region on imaging performance.

研究概览

详细说明

Background and Rationale

Magnetic resonance imaging (MRI) and fluorodeoxyglucose positron emission tomography/computed tomography (FDG-PET/CT) are widely used imaging modalities for the evaluation of cervical and lumbar spinal disorders. MRI primarily provides high-resolution anatomical information, whereas FDG-PET/CT provides metabolic and functional information that may assist in the assessment of inflammatory, infectious, degenerative, and neoplastic spinal conditions. Although both modalities are routinely used in clinical practice, differences in image quality characteristics and short-term physiological effects associated with imaging procedures remain areas of interest.

Study Design

This study is a prospective comparative observational study designed to evaluate image quality characteristics and short-term physiological effects associated with contrast-enhanced MRI and FDG-PET/CT in adult patients with cervical or lumbar spinal pathologies. A total of 120 participants are included, with 60 participants undergoing contrast-enhanced MRI and 60 participants undergoing FDG-PET/CT according to routine clinical indications and standard institutional workflows.

The study is non-interventional. No experimental treatments, investigational drugs, or deviations from standard clinical care are introduced. All imaging procedures are performed according to established institutional protocols and manufacturer recommendations.

Study Population

Eligible participants are adults with clinically suspected or confirmed cervical or lumbar spinal pathology requiring advanced imaging evaluation. Conditions may include degenerative, inflammatory, infectious, neoplastic, traumatic, or post-surgical spinal disorders.

Imaging Procedures

MRI examinations are performed using a 3 Tesla scanner equipped with a dedicated spinal coil. Standard spinal imaging protocols include sagittal and axial T1-weighted and T2-weighted sequences. Intravenous gadolinium-based contrast administration is performed according to institutional guidelines and standard clinical practice.

FDG-PET/CT examinations are performed following standard patient preparation procedures, including fasting requirements and blood glucose assessment. Intravenous administration of 18F-fluorodeoxyglucose (FDG) is followed by image acquisition using routine clinical PET/CT protocols. CT acquisition is used for attenuation correction and anatomical localization according to institutional practice.

Image Quality Assessment

Quantitative image quality assessment includes measurement of signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) using standardized regions of interest. Measurements are performed using predefined image analysis procedures to ensure consistency across participants.

Qualitative image quality assessment is performed using Visual Grading Analysis (VGA). Independent blinded radiologists evaluate image quality using predefined criteria related to anatomical detail, tissue contrast, lesion conspicuity, image noise, and overall diagnostic usability.

Physiological and Safety Assessments

Short-term physiological effects associated with imaging procedures are evaluated using laboratory measurements obtained before imaging and 48 hours after imaging. Laboratory assessments include blood urea nitrogen (BUN), estimated glomerular filtration rate (eGFR), and hemoglobin concentration.

Routine safety monitoring is performed according to institutional standards. Adverse events associated with contrast administration or imaging procedures are documented and managed according to standard clinical protocols.

Subgroup Analyses

Prespecified subgroup analyses evaluate image quality metrics according to spinal region (cervical versus lumbar) and age group (50 years or younger versus older than 50 years). These analyses are intended to explore potential differences in imaging performance across clinically relevant patient subgroups.

Study Objectives

The primary objectives are to compare quantitative image quality metrics between contrast-enhanced MRI and FDG-PET/CT and to evaluate qualitative image quality using blinded radiologist assessment.

Secondary objectives include assessment of short-term changes in renal and hematologic laboratory parameters following imaging procedures performed as part of routine clinical care.

Ethics

The study is conducted in accordance with applicable ethical principles, institutional policies, and approved research protocols. Institutional Review Board approval has been obtained, and informed consent procedures are implemented as required by the approved protocol and applicable regulations.

研究类型

观察性的

注册 (实际的)

120

联系人和位置

本节提供了进行研究的人员的详细联系信息,以及有关进行该研究的地点的信息。

学习地点

    • Giza Governorate
      • Giza、Giza Governorate、埃及、43556
        • (MISR University Scientific Research Innovation Committee,

参与标准

研究人员寻找符合特定描述的人,称为资格标准。这些标准的一些例子是一个人的一般健康状况或先前的治疗。

资格标准

适合学习的年龄

  • 孩子
  • 成人
  • 年长者

接受健康志愿者

是的

取样方法

非概率样本

研究人群

Participants will be recruited from the general population through community outreach, advertisements, and screening visits. Individuals who meet the eligibility criteria will be invited to participate.

描述

Inclusion Criteria:

  • Age 18 years or older.
  • Clinically suspected or confirmed cervical or lumbar spinal pathology.
  • Presence of symptoms suggestive of spinal disease, including radiculopathy, localized spinal pain, neurological deficits, or suspected metastatic involvement.
  • Referred for diagnostic evaluation with contrast-enhanced MRI or FDG-PET/CT according to routine clinical indications.
  • Availability of baseline clinical and laboratory data, including renal function assessment.
  • Ability to provide informed consent.

Exclusion Criteria:

  • Severe renal impairment (eGFR <30 mL/min/1.73 m²) or acute kidney injury.
  • Known hypersensitivity to gadolinium-based contrast agents or 18F-FDG.
  • Contraindications to MRI, including non-compatible metallic implants or severe claustrophobia.
  • Pregnancy or breastfeeding.
  • Uncontrolled diabetes mellitus (blood glucose >200 mg/dL at the time of PET/CT examination).
  • Active systemic infection or inflammatory condition requiring immediate treatment.
  • Inability to complete the required imaging procedures.
  • Incomplete clinical, laboratory, or imaging data required for study evaluation.

学习计划

本节提供研究计划的详细信息,包括研究的设计方式和研究的衡量标准。

研究是如何设计的?

设计细节

队列和干预

团体/队列
patient allocation to MRI (n=60) and FDG-PET/CT (n=60) groups with stratification by spinal re-gion

研究衡量的是什么?

主要结果指标

结果测量
措施说明
大体时间
Quantitative Image Quality Assessment
大体时间:Assessed at the imaging visit (up to 1 day).

Secondary Outcome Measure 1

Outcome Measure:

Blood Urea Nitrogen (BUN)

Description:

Change in serum blood urea nitrogen concentration following imaging procedures.

Time Frame:

Baseline (pre-imaging) and 48 hours post-imaging.

Unit of Measure:

mg/dL

Secondary Outcome Measure 2

Outcome Measure:

Estimated Glomerular Filtration Rate (eGFR)

Description:

Change in estimated glomerular filtration rate following imaging procedures.

Time Frame:

Baseline (pre-imaging) and 48 hours post-imaging.

Unit of Measure:

mL/min/1.73 m²

Secondary Outcome Measure 3

Outcome Measure:

Hemoglobin Level

Description:

Change in hemoglobin concentration following imaging procedures.

Time Frame:

Baseline (pre-imaging) and 48 hours post-imaging.

Unit of Measure:

g/dL

Secondary Outcome Measure 4

Outcome Measure:

Visual Grading Analysis (VGA) Score

Description:

Qualitative image quality assessment performed by blinded radiologists to evaluate anatomical clarity, lesion delineation, image contrast, and

Assessed at the imaging visit (up to 1 day).

次要结果测量

结果测量
措施说明
大体时间
Comparative Evaluation of Image Quality and Short-Term Physiological Effects of Contrast-Enhanced MRI versus FDG-PET/CT in Cervical and Lumbar Spine Pathologies
大体时间:For image quality assessment: At the time of imaging For short-term physiological effects (BUN, eGFR, hemoglobin): Baseline (pre-imaging) and 48 hours post-imaging

Short-term physiological effects of contrast-enhanced MRI and FDG-PET/CT, assessed via changes in renal function and hematologic parameters:

Serum blood urea nitrogen (BUN) at baseline and 48 hours post-imaging Estimated glomerular filtration rate (eGFR) at baseline and 48 hours post-imaging Hemoglobin levels at baseline and 48 hours post-imaging Qualitative image evaluation, measured by Visual Grading Analysis (VGA) performed by blinded radiologists to assess anatomical clarity, lesion delineation, and overall diagnostic usability.

For image quality assessment: At the time of imaging For short-term physiological effects (BUN, eGFR, hemoglobin): Baseline (pre-imaging) and 48 hours post-imaging

合作者和调查者

在这里您可以找到参与这项研究的人员和组织。

出版物和有用的链接

负责输入研究信息的人员自愿提供这些出版物。这些可能与研究有关。

一般刊物

  • References 1. Altman, D.G. Practical Statistics for Medical Research (1st ed.); Chapman and Hall/CRC, 1990. 2. Andreucci, M.; Solomon, R.; Tasanarong, A. Side effects of radiographic contrast media: pathogenesis, risk factors, and pre-vention. Biomed Res Int. 2014, 2014, 741018. 3. Association, W.M. World Medical Association Declaration of Helsinki: ethical principles for medical research involving human subjects. Jama 2013, 310, 2191-4. 4. Bajwa, H.; Sritharan, T.; Botha, T.; et al. Assessment of cervical spine CT by an image quality audit using qualitative and quantitative methods. J Med Imaging Radiat Oncol. 2025, 69, 7-16. 5. Benchoufi, M.; Matzner-Lober, E.; Molinari, N.; et al. Interobserver agreement issues in radiology. Diagn Interv Imaging 2020, 101, 639-41. 6. Beyer, T.; Bailey, D.L.; Birk, U.J.; et al. Medical Physics and Imaging-A Timely Perspective. Front. Phys. 2021, 9, 634693. 7. Boellaard, R.; Delgado-Bolton, R.; Oyen, W.J.; et al. FDG PET/CT: EANM procedure guidelines for tumour imaging: version 2.0. Eur J Nucl Med Mol Imaging. 2015, 42, 328-54. 8. Boos, N.; Rieder, R.; Schade, V.; et al. The Imaging characteristics of Magnetic Resonance Imaging, Work Perception, and Psychosocial Factors in Identifying Symptomatic Disc Herniations. Spine 1995, 20. 9. Boriani, L.; Zamparini, E.; Albrizio, M.; et al. Spine Infections: The Role of Fluorodeoxyglucose Positron Emission Tomography (FDG PET) in the Context of the Actual Diagnosis Guideline. Curr Med Imaging 2022, 18, 216-30. 10. Brinjikji, W.; Luetmer, P.H.; Comstock, B.; et al. Systematic literature review of imaging features of spinal degeneration in asymptomatic populations. AJNR Am J Neuroradiol. 2015, 36, 811-6. 11. Brown, T.F.; Yasillo, N.J. Radiation safety considerations for PET centers. J Nucl Med Technol. 1997, 25, 98-102; quiz 4-5. 12. Burmeister, H.P.; Baltzer, P.A.; Möslein, C.; et al. Visual grading characteristics (VGC) analysis of diagnostic image quality for high resolution 3 Tesla MRI vol

研究记录日期

这些日期跟踪向 ClinicalTrials.gov 提交研究记录和摘要结果的进度。研究记录和报告的结果由国家医学图书馆 (NLM) 审查,以确保它们在发布到公共网站之前符合特定的质量控制标准。

研究主要日期

学习开始 (实际的)

2025年4月5日

初级完成 (实际的)

2025年11月3日

研究完成 (实际的)

2026年1月1日

研究注册日期

首次提交

2026年5月31日

首先提交符合 QC 标准的

2026年6月5日

首次发布 (实际的)

2026年6月10日

研究记录更新

最后更新发布 (实际的)

2026年6月10日

上次提交的符合 QC 标准的更新

2026年6月5日

最后验证

2026年6月1日

更多信息

与本研究相关的术语

计划个人参与者数据 (IPD)

计划共享个人参与者数据 (IPD)?

未定

药物和器械信息、研究文件

研究美国 FDA 监管的药品

不

研究美国 FDA 监管的设备产品

不

此信息直接从 clinicaltrials.gov 网站检索,没有任何更改。如果您有任何更改、删除或更新研究详细信息的请求,请联系 register@clinicaltrials.gov. clinicaltrials.gov 上实施更改,我们的网站上也会自动更新.

订阅