Denna sida har översatts automatiskt och översättningens korrekthet kan inte garanteras. Vänligen se engelsk version för en källtext.

Comparative Evaluation of Contrast-Enhanced MRI and FDG-PET/CT in Spinal Pathology: Image Quality and Short-Term Renal-Hematologic Safety

5 juni 2026 uppdaterad av: Ahmed Elgendi, Cairo University

This prospective comparative observational study evaluates image quality characteristics and short-term physiological effects associated with contrast-enhanced magnetic resonance imaging (MRI) and fluorodeoxyglucose positron emission tomography/computed tomography (FDG-PET/CT) in patients with cervical and lumbar spinal pathologies.

A total of 120 adult participants undergo either contrast-enhanced MRI or FDG-PET/CT as part of routine clinical evaluation. Image quality is assessed using quantitative metrics, including signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR), as well as qualitative Visual Grading Analysis (VGA) performed by blinded radiologists. Short-term physiological effects are evaluated using blood urea nitrogen (BUN), estimated glomerular filtration rate (eGFR), and hemoglobin measurements obtained before imaging and 48 hours after imaging.

The study aims to compare image quality characteristics and short-term physiological parameters associated with these imaging modalities and to examine the influence of age group and spinal region on imaging performance.

Studieöversikt

Detaljerad beskrivning

Background and Rationale

Magnetic resonance imaging (MRI) and fluorodeoxyglucose positron emission tomography/computed tomography (FDG-PET/CT) are widely used imaging modalities for the evaluation of cervical and lumbar spinal disorders. MRI primarily provides high-resolution anatomical information, whereas FDG-PET/CT provides metabolic and functional information that may assist in the assessment of inflammatory, infectious, degenerative, and neoplastic spinal conditions. Although both modalities are routinely used in clinical practice, differences in image quality characteristics and short-term physiological effects associated with imaging procedures remain areas of interest.

Study Design

This study is a prospective comparative observational study designed to evaluate image quality characteristics and short-term physiological effects associated with contrast-enhanced MRI and FDG-PET/CT in adult patients with cervical or lumbar spinal pathologies. A total of 120 participants are included, with 60 participants undergoing contrast-enhanced MRI and 60 participants undergoing FDG-PET/CT according to routine clinical indications and standard institutional workflows.

The study is non-interventional. No experimental treatments, investigational drugs, or deviations from standard clinical care are introduced. All imaging procedures are performed according to established institutional protocols and manufacturer recommendations.

Study Population

Eligible participants are adults with clinically suspected or confirmed cervical or lumbar spinal pathology requiring advanced imaging evaluation. Conditions may include degenerative, inflammatory, infectious, neoplastic, traumatic, or post-surgical spinal disorders.

Imaging Procedures

MRI examinations are performed using a 3 Tesla scanner equipped with a dedicated spinal coil. Standard spinal imaging protocols include sagittal and axial T1-weighted and T2-weighted sequences. Intravenous gadolinium-based contrast administration is performed according to institutional guidelines and standard clinical practice.

FDG-PET/CT examinations are performed following standard patient preparation procedures, including fasting requirements and blood glucose assessment. Intravenous administration of 18F-fluorodeoxyglucose (FDG) is followed by image acquisition using routine clinical PET/CT protocols. CT acquisition is used for attenuation correction and anatomical localization according to institutional practice.

Image Quality Assessment

Quantitative image quality assessment includes measurement of signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) using standardized regions of interest. Measurements are performed using predefined image analysis procedures to ensure consistency across participants.

Qualitative image quality assessment is performed using Visual Grading Analysis (VGA). Independent blinded radiologists evaluate image quality using predefined criteria related to anatomical detail, tissue contrast, lesion conspicuity, image noise, and overall diagnostic usability.

Physiological and Safety Assessments

Short-term physiological effects associated with imaging procedures are evaluated using laboratory measurements obtained before imaging and 48 hours after imaging. Laboratory assessments include blood urea nitrogen (BUN), estimated glomerular filtration rate (eGFR), and hemoglobin concentration.

Routine safety monitoring is performed according to institutional standards. Adverse events associated with contrast administration or imaging procedures are documented and managed according to standard clinical protocols.

Subgroup Analyses

Prespecified subgroup analyses evaluate image quality metrics according to spinal region (cervical versus lumbar) and age group (50 years or younger versus older than 50 years). These analyses are intended to explore potential differences in imaging performance across clinically relevant patient subgroups.

Study Objectives

The primary objectives are to compare quantitative image quality metrics between contrast-enhanced MRI and FDG-PET/CT and to evaluate qualitative image quality using blinded radiologist assessment.

Secondary objectives include assessment of short-term changes in renal and hematologic laboratory parameters following imaging procedures performed as part of routine clinical care.

Ethics

The study is conducted in accordance with applicable ethical principles, institutional policies, and approved research protocols. Institutional Review Board approval has been obtained, and informed consent procedures are implemented as required by the approved protocol and applicable regulations.

Studietyp

Observationell

Inskrivning (Faktisk)

120

Kontakter och platser

Det här avsnittet innehåller kontaktuppgifter för dem som genomför studien och information om var denna studie genomförs.

Studieorter

    • Giza Governorate
      • Giza, Giza Governorate, Egypten, 43556
        • (MISR University Scientific Research Innovation Committee,

Deltagandekriterier

Forskare letar efter personer som passar en viss beskrivning, så kallade behörighetskriterier. Några exempel på dessa kriterier är en persons allmänna hälsotillstånd eller tidigare behandlingar.

Urvalskriterier

Åldrar som är berättigade till studier

  • Barn
  • Vuxen
  • Äldre vuxen

Tar emot friska volontärer

Ja

Testmetod

Icke-sannolikhetsprov

Studera befolkning

Participants will be recruited from the general population through community outreach, advertisements, and screening visits. Individuals who meet the eligibility criteria will be invited to participate.

Beskrivning

Inclusion Criteria:

  • Age 18 years or older.
  • Clinically suspected or confirmed cervical or lumbar spinal pathology.
  • Presence of symptoms suggestive of spinal disease, including radiculopathy, localized spinal pain, neurological deficits, or suspected metastatic involvement.
  • Referred for diagnostic evaluation with contrast-enhanced MRI or FDG-PET/CT according to routine clinical indications.
  • Availability of baseline clinical and laboratory data, including renal function assessment.
  • Ability to provide informed consent.

Exclusion Criteria:

  • Severe renal impairment (eGFR <30 mL/min/1.73 m²) or acute kidney injury.
  • Known hypersensitivity to gadolinium-based contrast agents or 18F-FDG.
  • Contraindications to MRI, including non-compatible metallic implants or severe claustrophobia.
  • Pregnancy or breastfeeding.
  • Uncontrolled diabetes mellitus (blood glucose >200 mg/dL at the time of PET/CT examination).
  • Active systemic infection or inflammatory condition requiring immediate treatment.
  • Inability to complete the required imaging procedures.
  • Incomplete clinical, laboratory, or imaging data required for study evaluation.

Studieplan

Det här avsnittet ger detaljer om studieplanen, inklusive hur studien är utformad och vad studien mäter.

Hur är studien utformad?

Designdetaljer

Kohorter och interventioner

Grupp / Kohort
patient allocation to MRI (n=60) and FDG-PET/CT (n=60) groups with stratification by spinal re-gion

Vad mäter studien?

Primära resultatmått

Resultatmått
Åtgärdsbeskrivning
Tidsram
Quantitative Image Quality Assessment
Tidsram: Assessed at the imaging visit (up to 1 day).

Secondary Outcome Measure 1

Outcome Measure:

Blood Urea Nitrogen (BUN)

Description:

Change in serum blood urea nitrogen concentration following imaging procedures.

Time Frame:

Baseline (pre-imaging) and 48 hours post-imaging.

Unit of Measure:

mg/dL

Secondary Outcome Measure 2

Outcome Measure:

Estimated Glomerular Filtration Rate (eGFR)

Description:

Change in estimated glomerular filtration rate following imaging procedures.

Time Frame:

Baseline (pre-imaging) and 48 hours post-imaging.

Unit of Measure:

mL/min/1.73 m²

Secondary Outcome Measure 3

Outcome Measure:

Hemoglobin Level

Description:

Change in hemoglobin concentration following imaging procedures.

Time Frame:

Baseline (pre-imaging) and 48 hours post-imaging.

Unit of Measure:

g/dL

Secondary Outcome Measure 4

Outcome Measure:

Visual Grading Analysis (VGA) Score

Description:

Qualitative image quality assessment performed by blinded radiologists to evaluate anatomical clarity, lesion delineation, image contrast, and

Assessed at the imaging visit (up to 1 day).

Sekundära resultatmått

Resultatmått
Åtgärdsbeskrivning
Tidsram
Comparative Evaluation of Image Quality and Short-Term Physiological Effects of Contrast-Enhanced MRI versus FDG-PET/CT in Cervical and Lumbar Spine Pathologies
Tidsram: For image quality assessment: At the time of imaging For short-term physiological effects (BUN, eGFR, hemoglobin): Baseline (pre-imaging) and 48 hours post-imaging

Short-term physiological effects of contrast-enhanced MRI and FDG-PET/CT, assessed via changes in renal function and hematologic parameters:

Serum blood urea nitrogen (BUN) at baseline and 48 hours post-imaging Estimated glomerular filtration rate (eGFR) at baseline and 48 hours post-imaging Hemoglobin levels at baseline and 48 hours post-imaging Qualitative image evaluation, measured by Visual Grading Analysis (VGA) performed by blinded radiologists to assess anatomical clarity, lesion delineation, and overall diagnostic usability.

For image quality assessment: At the time of imaging For short-term physiological effects (BUN, eGFR, hemoglobin): Baseline (pre-imaging) and 48 hours post-imaging

Samarbetspartners och utredare

Det är här du hittar personer och organisationer som är involverade i denna studie.

Publikationer och användbara länkar

Den som ansvarar för att lägga in information om studien tillhandahåller frivilligt dessa publikationer. Dessa kan handla om allt som har med studien att göra.

Allmänna publikationer

  • References 1. Altman, D.G. Practical Statistics for Medical Research (1st ed.); Chapman and Hall/CRC, 1990. 2. Andreucci, M.; Solomon, R.; Tasanarong, A. Side effects of radiographic contrast media: pathogenesis, risk factors, and pre-vention. Biomed Res Int. 2014, 2014, 741018. 3. Association, W.M. World Medical Association Declaration of Helsinki: ethical principles for medical research involving human subjects. Jama 2013, 310, 2191-4. 4. Bajwa, H.; Sritharan, T.; Botha, T.; et al. Assessment of cervical spine CT by an image quality audit using qualitative and quantitative methods. J Med Imaging Radiat Oncol. 2025, 69, 7-16. 5. Benchoufi, M.; Matzner-Lober, E.; Molinari, N.; et al. Interobserver agreement issues in radiology. Diagn Interv Imaging 2020, 101, 639-41. 6. Beyer, T.; Bailey, D.L.; Birk, U.J.; et al. Medical Physics and Imaging-A Timely Perspective. Front. Phys. 2021, 9, 634693. 7. Boellaard, R.; Delgado-Bolton, R.; Oyen, W.J.; et al. FDG PET/CT: EANM procedure guidelines for tumour imaging: version 2.0. Eur J Nucl Med Mol Imaging. 2015, 42, 328-54. 8. Boos, N.; Rieder, R.; Schade, V.; et al. The Imaging characteristics of Magnetic Resonance Imaging, Work Perception, and Psychosocial Factors in Identifying Symptomatic Disc Herniations. Spine 1995, 20. 9. Boriani, L.; Zamparini, E.; Albrizio, M.; et al. Spine Infections: The Role of Fluorodeoxyglucose Positron Emission Tomography (FDG PET) in the Context of the Actual Diagnosis Guideline. Curr Med Imaging 2022, 18, 216-30. 10. Brinjikji, W.; Luetmer, P.H.; Comstock, B.; et al. Systematic literature review of imaging features of spinal degeneration in asymptomatic populations. AJNR Am J Neuroradiol. 2015, 36, 811-6. 11. Brown, T.F.; Yasillo, N.J. Radiation safety considerations for PET centers. J Nucl Med Technol. 1997, 25, 98-102; quiz 4-5. 12. Burmeister, H.P.; Baltzer, P.A.; Möslein, C.; et al. Visual grading characteristics (VGC) analysis of diagnostic image quality for high resolution 3 Tesla MRI vol

Studieavstämningsdatum

Dessa datum spårar framstegen för inlämningar av studieposter och sammanfattande resultat till ClinicalTrials.gov. Studieposter och rapporterade resultat granskas av National Library of Medicine (NLM) för att säkerställa att de uppfyller specifika kvalitetskontrollstandarder innan de publiceras på den offentliga webbplatsen.

Studera stora datum

Studiestart (Faktisk)

5 april 2025

Primärt slutförande (Faktisk)

3 november 2025

Avslutad studie (Faktisk)

1 januari 2026

Studieregistreringsdatum

Först inskickad

31 maj 2026

Först inskickad som uppfyllde QC-kriterierna

5 juni 2026

Första postat (Faktisk)

10 juni 2026

Uppdateringar av studier

Senaste uppdatering publicerad (Faktisk)

10 juni 2026

Senaste inskickade uppdateringen som uppfyllde QC-kriterierna

5 juni 2026

Senast verifierad

1 juni 2026

Mer information

Termer relaterade till denna studie

Plan för individuella deltagardata (IPD)

Planerar du att dela individuella deltagardata (IPD)?

OBESLUTSAM

Läkemedels- och apparatinformation, studiedokument

Studerar en amerikansk FDA-reglerad läkemedelsprodukt

Nej

Studerar en amerikansk FDA-reglerad produktprodukt

Nej

Denna information hämtades direkt från webbplatsen clinicaltrials.gov utan några ändringar. Om du har några önskemål om att ändra, ta bort eller uppdatera dina studieuppgifter, vänligen kontakta register@clinicaltrials.gov. Så snart en ändring har implementerats på clinicaltrials.gov, kommer denna att uppdateras automatiskt även på vår webbplats .

Prenumerera