Tato stránka byla automaticky přeložena a přesnost překladu není zaručena. Podívejte se prosím na anglická verze pro zdrojový text.

Comparative Evaluation of Contrast-Enhanced MRI and FDG-PET/CT in Spinal Pathology: Image Quality and Short-Term Renal-Hematologic Safety

5. června 2026 aktualizováno: Ahmed Elgendi, Cairo University

This prospective comparative observational study evaluates image quality characteristics and short-term physiological effects associated with contrast-enhanced magnetic resonance imaging (MRI) and fluorodeoxyglucose positron emission tomography/computed tomography (FDG-PET/CT) in patients with cervical and lumbar spinal pathologies.

A total of 120 adult participants undergo either contrast-enhanced MRI or FDG-PET/CT as part of routine clinical evaluation. Image quality is assessed using quantitative metrics, including signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR), as well as qualitative Visual Grading Analysis (VGA) performed by blinded radiologists. Short-term physiological effects are evaluated using blood urea nitrogen (BUN), estimated glomerular filtration rate (eGFR), and hemoglobin measurements obtained before imaging and 48 hours after imaging.

The study aims to compare image quality characteristics and short-term physiological parameters associated with these imaging modalities and to examine the influence of age group and spinal region on imaging performance.

Přehled studie

Detailní popis

Background and Rationale

Magnetic resonance imaging (MRI) and fluorodeoxyglucose positron emission tomography/computed tomography (FDG-PET/CT) are widely used imaging modalities for the evaluation of cervical and lumbar spinal disorders. MRI primarily provides high-resolution anatomical information, whereas FDG-PET/CT provides metabolic and functional information that may assist in the assessment of inflammatory, infectious, degenerative, and neoplastic spinal conditions. Although both modalities are routinely used in clinical practice, differences in image quality characteristics and short-term physiological effects associated with imaging procedures remain areas of interest.

Study Design

This study is a prospective comparative observational study designed to evaluate image quality characteristics and short-term physiological effects associated with contrast-enhanced MRI and FDG-PET/CT in adult patients with cervical or lumbar spinal pathologies. A total of 120 participants are included, with 60 participants undergoing contrast-enhanced MRI and 60 participants undergoing FDG-PET/CT according to routine clinical indications and standard institutional workflows.

The study is non-interventional. No experimental treatments, investigational drugs, or deviations from standard clinical care are introduced. All imaging procedures are performed according to established institutional protocols and manufacturer recommendations.

Study Population

Eligible participants are adults with clinically suspected or confirmed cervical or lumbar spinal pathology requiring advanced imaging evaluation. Conditions may include degenerative, inflammatory, infectious, neoplastic, traumatic, or post-surgical spinal disorders.

Imaging Procedures

MRI examinations are performed using a 3 Tesla scanner equipped with a dedicated spinal coil. Standard spinal imaging protocols include sagittal and axial T1-weighted and T2-weighted sequences. Intravenous gadolinium-based contrast administration is performed according to institutional guidelines and standard clinical practice.

FDG-PET/CT examinations are performed following standard patient preparation procedures, including fasting requirements and blood glucose assessment. Intravenous administration of 18F-fluorodeoxyglucose (FDG) is followed by image acquisition using routine clinical PET/CT protocols. CT acquisition is used for attenuation correction and anatomical localization according to institutional practice.

Image Quality Assessment

Quantitative image quality assessment includes measurement of signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) using standardized regions of interest. Measurements are performed using predefined image analysis procedures to ensure consistency across participants.

Qualitative image quality assessment is performed using Visual Grading Analysis (VGA). Independent blinded radiologists evaluate image quality using predefined criteria related to anatomical detail, tissue contrast, lesion conspicuity, image noise, and overall diagnostic usability.

Physiological and Safety Assessments

Short-term physiological effects associated with imaging procedures are evaluated using laboratory measurements obtained before imaging and 48 hours after imaging. Laboratory assessments include blood urea nitrogen (BUN), estimated glomerular filtration rate (eGFR), and hemoglobin concentration.

Routine safety monitoring is performed according to institutional standards. Adverse events associated with contrast administration or imaging procedures are documented and managed according to standard clinical protocols.

Subgroup Analyses

Prespecified subgroup analyses evaluate image quality metrics according to spinal region (cervical versus lumbar) and age group (50 years or younger versus older than 50 years). These analyses are intended to explore potential differences in imaging performance across clinically relevant patient subgroups.

Study Objectives

The primary objectives are to compare quantitative image quality metrics between contrast-enhanced MRI and FDG-PET/CT and to evaluate qualitative image quality using blinded radiologist assessment.

Secondary objectives include assessment of short-term changes in renal and hematologic laboratory parameters following imaging procedures performed as part of routine clinical care.

Ethics

The study is conducted in accordance with applicable ethical principles, institutional policies, and approved research protocols. Institutional Review Board approval has been obtained, and informed consent procedures are implemented as required by the approved protocol and applicable regulations.

Typ studie

Pozorovací

Zápis (Aktuální)

120

Kontakty a umístění

Tato část poskytuje kontaktní údaje pro ty, kteří studii provádějí, a informace o tom, kde se tato studie provádí.

Studijní místa

    • Giza Governorate
      • Giza, Giza Governorate, Egypt, 43556
        • (MISR University Scientific Research Innovation Committee,

Kritéria účasti

Výzkumníci hledají lidi, kteří odpovídají určitému popisu, kterému se říká kritéria způsobilosti. Některé příklady těchto kritérií jsou celkový zdravotní stav osoby nebo předchozí léčba.

Kritéria způsobilosti

Věk způsobilý ke studiu

  • Dítě
  • Dospělý
  • Starší dospělý

Přijímá zdravé dobrovolníky

Ano

Metoda odběru vzorků

Vzorek nepravděpodobnosti

Studijní populace

Participants will be recruited from the general population through community outreach, advertisements, and screening visits. Individuals who meet the eligibility criteria will be invited to participate.

Popis

Inclusion Criteria:

  • Age 18 years or older.
  • Clinically suspected or confirmed cervical or lumbar spinal pathology.
  • Presence of symptoms suggestive of spinal disease, including radiculopathy, localized spinal pain, neurological deficits, or suspected metastatic involvement.
  • Referred for diagnostic evaluation with contrast-enhanced MRI or FDG-PET/CT according to routine clinical indications.
  • Availability of baseline clinical and laboratory data, including renal function assessment.
  • Ability to provide informed consent.

Exclusion Criteria:

  • Severe renal impairment (eGFR <30 mL/min/1.73 m²) or acute kidney injury.
  • Known hypersensitivity to gadolinium-based contrast agents or 18F-FDG.
  • Contraindications to MRI, including non-compatible metallic implants or severe claustrophobia.
  • Pregnancy or breastfeeding.
  • Uncontrolled diabetes mellitus (blood glucose >200 mg/dL at the time of PET/CT examination).
  • Active systemic infection or inflammatory condition requiring immediate treatment.
  • Inability to complete the required imaging procedures.
  • Incomplete clinical, laboratory, or imaging data required for study evaluation.

Studijní plán

Tato část poskytuje podrobnosti o studijním plánu, včetně toho, jak je studie navržena a co studie měří.

Jak je studie koncipována?

Detaily designu

Kohorty a intervence

Skupina / kohorta
patient allocation to MRI (n=60) and FDG-PET/CT (n=60) groups with stratification by spinal re-gion

Co je měření studie?

Primární výstupní opatření

Měření výsledku
Popis opatření
Časové okno
Quantitative Image Quality Assessment
Časové okno: Assessed at the imaging visit (up to 1 day).

Secondary Outcome Measure 1

Outcome Measure:

Blood Urea Nitrogen (BUN)

Description:

Change in serum blood urea nitrogen concentration following imaging procedures.

Time Frame:

Baseline (pre-imaging) and 48 hours post-imaging.

Unit of Measure:

mg/dL

Secondary Outcome Measure 2

Outcome Measure:

Estimated Glomerular Filtration Rate (eGFR)

Description:

Change in estimated glomerular filtration rate following imaging procedures.

Time Frame:

Baseline (pre-imaging) and 48 hours post-imaging.

Unit of Measure:

mL/min/1.73 m²

Secondary Outcome Measure 3

Outcome Measure:

Hemoglobin Level

Description:

Change in hemoglobin concentration following imaging procedures.

Time Frame:

Baseline (pre-imaging) and 48 hours post-imaging.

Unit of Measure:

g/dL

Secondary Outcome Measure 4

Outcome Measure:

Visual Grading Analysis (VGA) Score

Description:

Qualitative image quality assessment performed by blinded radiologists to evaluate anatomical clarity, lesion delineation, image contrast, and

Assessed at the imaging visit (up to 1 day).

Sekundární výstupní opatření

Měření výsledku
Popis opatření
Časové okno
Comparative Evaluation of Image Quality and Short-Term Physiological Effects of Contrast-Enhanced MRI versus FDG-PET/CT in Cervical and Lumbar Spine Pathologies
Časové okno: For image quality assessment: At the time of imaging For short-term physiological effects (BUN, eGFR, hemoglobin): Baseline (pre-imaging) and 48 hours post-imaging

Short-term physiological effects of contrast-enhanced MRI and FDG-PET/CT, assessed via changes in renal function and hematologic parameters:

Serum blood urea nitrogen (BUN) at baseline and 48 hours post-imaging Estimated glomerular filtration rate (eGFR) at baseline and 48 hours post-imaging Hemoglobin levels at baseline and 48 hours post-imaging Qualitative image evaluation, measured by Visual Grading Analysis (VGA) performed by blinded radiologists to assess anatomical clarity, lesion delineation, and overall diagnostic usability.

For image quality assessment: At the time of imaging For short-term physiological effects (BUN, eGFR, hemoglobin): Baseline (pre-imaging) and 48 hours post-imaging

Spolupracovníci a vyšetřovatelé

Zde najdete lidi a organizace zapojené do této studie.

Publikace a užitečné odkazy

Osoba odpovědná za zadávání informací o studiu tyto publikace poskytuje dobrovolně. Mohou se týkat čehokoli, co souvisí se studiem.

Obecné publikace

  • References 1. Altman, D.G. Practical Statistics for Medical Research (1st ed.); Chapman and Hall/CRC, 1990. 2. Andreucci, M.; Solomon, R.; Tasanarong, A. Side effects of radiographic contrast media: pathogenesis, risk factors, and pre-vention. Biomed Res Int. 2014, 2014, 741018. 3. Association, W.M. World Medical Association Declaration of Helsinki: ethical principles for medical research involving human subjects. Jama 2013, 310, 2191-4. 4. Bajwa, H.; Sritharan, T.; Botha, T.; et al. Assessment of cervical spine CT by an image quality audit using qualitative and quantitative methods. J Med Imaging Radiat Oncol. 2025, 69, 7-16. 5. Benchoufi, M.; Matzner-Lober, E.; Molinari, N.; et al. Interobserver agreement issues in radiology. Diagn Interv Imaging 2020, 101, 639-41. 6. Beyer, T.; Bailey, D.L.; Birk, U.J.; et al. Medical Physics and Imaging-A Timely Perspective. Front. Phys. 2021, 9, 634693. 7. Boellaard, R.; Delgado-Bolton, R.; Oyen, W.J.; et al. FDG PET/CT: EANM procedure guidelines for tumour imaging: version 2.0. Eur J Nucl Med Mol Imaging. 2015, 42, 328-54. 8. Boos, N.; Rieder, R.; Schade, V.; et al. The Imaging characteristics of Magnetic Resonance Imaging, Work Perception, and Psychosocial Factors in Identifying Symptomatic Disc Herniations. Spine 1995, 20. 9. Boriani, L.; Zamparini, E.; Albrizio, M.; et al. Spine Infections: The Role of Fluorodeoxyglucose Positron Emission Tomography (FDG PET) in the Context of the Actual Diagnosis Guideline. Curr Med Imaging 2022, 18, 216-30. 10. Brinjikji, W.; Luetmer, P.H.; Comstock, B.; et al. Systematic literature review of imaging features of spinal degeneration in asymptomatic populations. AJNR Am J Neuroradiol. 2015, 36, 811-6. 11. Brown, T.F.; Yasillo, N.J. Radiation safety considerations for PET centers. J Nucl Med Technol. 1997, 25, 98-102; quiz 4-5. 12. Burmeister, H.P.; Baltzer, P.A.; Möslein, C.; et al. Visual grading characteristics (VGC) analysis of diagnostic image quality for high resolution 3 Tesla MRI vol

Termíny studijních záznamů

Tato data sledují průběh záznamů studie a předkládání souhrnných výsledků na ClinicalTrials.gov. Záznamy ze studií a hlášené výsledky jsou před zveřejněním na veřejné webové stránce přezkoumány Národní lékařskou knihovnou (NLM), aby se ujistily, že splňují specifické standardy kontroly kvality.

Hlavní termíny studia

Začátek studia (Aktuální)

5. dubna 2025

Primární dokončení (Aktuální)

3. listopadu 2025

Dokončení studie (Aktuální)

1. ledna 2026

Termíny zápisu do studia

První předloženo

31. května 2026

První předloženo, které splnilo kritéria kontroly kvality

5. června 2026

První zveřejněno (Aktuální)

10. června 2026

Aktualizace studijních záznamů

Poslední zveřejněná aktualizace (Aktuální)

10. června 2026

Odeslaná poslední aktualizace, která splnila kritéria kontroly kvality

5. června 2026

Naposledy ověřeno

1. června 2026

Více informací

Termíny související s touto studií

Plán pro data jednotlivých účastníků (IPD)

Plánujete sdílet data jednotlivých účastníků (IPD)?

NEROZHODNÝ

Informace o lécích a zařízeních, studijní dokumenty

Studuje lékový produkt regulovaný americkým FDA

Ne

Studuje produkt zařízení regulovaný americkým úřadem FDA

Ne

Tyto informace byly beze změn načteny přímo z webu clinicaltrials.gov. Máte-li jakékoli požadavky na změnu, odstranění nebo aktualizaci podrobností studie, kontaktujte prosím register@clinicaltrials.gov. Jakmile bude změna implementována na clinicaltrials.gov, bude automaticky aktualizována i na našem webu .

Předplatit