Preliminary Clinical Evaluation of a Novel Bi-dimensional Archwire During Miniscrew-Supported En-masse Retraction of the Maxillary Anterior Teeth

This study aims to provide a preliminary clinical evaluation of a novel bi-dimensional archwire used during miniscrew-supported en-masse retraction of the maxillary anterior teeth. Adult patients with Class II Division 1 malocclusion requiring extraction of the maxillary first premolars will be screened at the Department of Orthodontics, Faculty of Dentistry, Damascus University. Eligible participants will receive fixed orthodontic treatment followed by en-masse retraction using a custom-made laser-welded bi-dimensional stainless-steel archwire consisting of a 0.019 × 0.025-inch anterior segment and 0.016 × 0.022-inch posterior segments. Retraction will be supported by orthodontic miniscrews and nickel-titanium closed-coil springs. The main outcome will be the monthly rate of maxillary anterior retraction assessed on three-dimensional digital dental models. A secondary outcome will be the change in maxillary incisor torque assessed on lateral cephalometric radiographs. This pilot study is intended to generate preliminary clinical data regarding the feasibility and performance of this novel archwire design.

研究概览

详细说明

This study was designed as a prospective single-arm pilot clinical trial to provide an initial clinical evaluation of a novel bi-dimensional archwire specifically developed for miniscrew-supported en-masse retraction of the maxillary anterior teeth. In adult orthodontic patients requiring extraction-based treatment, effective space closure depends not only on anchorage control, but also on the ability of the active retraction system to maintain acceptable control of the maxillary incisors during sliding mechanics. Conventional continuous rectangular stainless-steel archwires provide rigidity, but they may still be associated with frictional resistance, wire deformation, and incomplete torque control during retraction.

The archwire investigated in this study was newly developed as a single continuous stainless-steel assembly composed of a 0.019 × 0.025-inch anterior segment and 0.016 × 0.022-inch posterior segments joined by laser welding. The design was intended to combine greater anterior stiffness, to support better torque control of the maxillary incisors, with reduced posterior friction and binding during sliding mechanics. The intervention was applied under direct skeletal anchorage using self-drilling orthodontic miniscrews inserted bilaterally between the maxillary second premolars and first molars. Retraction was performed using nickel-titanium closed-coil springs delivering approximately 250 g of force per side.

Eligible participants were adult patients with skeletal Class II malocclusion and Class II Division 1 dental malocclusion who required extraction of the maxillary first premolars and en-masse retraction of the maxillary anterior teeth as part of their treatment plan. After leveling and alignment, the novel bi-dimensional archwire was inserted and the retraction phase was initiated. Participants were followed prospectively until completion of the en-masse retraction phase.

The primary outcome of the study was the monthly rate of maxillary anterior en-masse retraction assessed on three-dimensional digital dental models. The secondary outcome was the change in maxillary incisor torque measured on standardized lateral cephalometric radiographs using the bracket-archwire angle. This pilot trial was undertaken to determine whether this newly developed archwire could function as a clinically feasible biomechanical option and to generate preliminary outcome estimates for future randomized controlled trials.

研究类型

介入性

注册 (实际的)

6

阶段

  • 不适用

联系人和位置

本节提供了进行研究的人员的详细联系信息,以及有关进行该研究的地点的信息。

学习地点

      • Damascus、叙利亚、DM20AM19
        • Department of Orthodontics, Faculty of Dentistry, University of Damascus

参与标准

研究人员寻找符合特定描述的人,称为资格标准。这些标准的一些例子是一个人的一般健康状况或先前的治疗。

资格标准

适合学习的年龄

  • 成人

接受健康志愿者

不

描述

Inclusion Criteria:

  • Adults aged 18-28 years with skeletal Class II malocclusion (ANB angle 5°-7°)
  • Class II Division 1 dental malocclusion according to Angle classification
  • An average or vertical facial growth pattern
  • A treatment plan requiring extraction of the maxillary first premolars
  • A need for maxillary anterior en-masse retraction
  • The presence of all permanent maxillary teeth except the third molars

Exclusion Criteria:

  • Patients with previous orthodontic treatment,
  • Craniofacial anomalies, systemic diseases affecting bone metabolism
  • Active periodontal disease
  • Poor oral hygiene
  • Missing maxillary permanent teeth, or were using
  • The use of medications known to influence bone metabolism

学习计划

本节提供研究计划的详细信息,包括研究的设计方式和研究的衡量标准。

研究是如何设计的?

设计细节

  • 主要用途:治疗
  • 分配:不适用
  • 介入模型:单组作业
  • 屏蔽:无(打开标签)

武器和干预

参与者组/臂
干预/治疗
实验性的:Bi-dimensional archwire
Participants will be treated using a novel bi-dimensional stainless-steel archwire during miniscrew-supported en-masse retraction of the maxillary anterior teeth
The retraction procedure is going to be conducted using a bi-dimensional archwire which is a single continuous stainless-steel assembly composed of a 0.019 × 0.025-inch anterior segment and 0.016 × 0.022-inch posterior segments joined by laser welding.

研究衡量的是什么?

主要结果指标

结果测量
措施说明
大体时间
Change in the monthly rate of maxillary anterior en-masse retraction
大体时间:Time 0: completion of leveling and alignment which happens within three months); Times 1, 2, 3, 4, 5 after one, two, three, four, and five months following the end of the leveling and alignment stage; Time Final: at the end of the retraction stage.
The amount of maxillary anterior retraction is assessed on three-dimensional digital dental models using the distance between the incisal edge of the maxillary central incisors and the medial point of the third palatal rugae as a stable intraoral reference. The monthly retraction rate is calculated in millimeters per month by dividing the amount of anterior retraction by the corresponding duration of the retraction interval.
Time 0: completion of leveling and alignment which happens within three months); Times 1, 2, 3, 4, 5 after one, two, three, four, and five months following the end of the leveling and alignment stage; Time Final: at the end of the retraction stage.

次要结果测量

结果测量
措施说明
大体时间
Change in maxillary incisor torque
大体时间:Time 0: completion of leveling and alignment stage which is expected to occur within three months, and Time Final: completion of en-masse retraction stage which occurs within 9 - 10 months following the end of the leveling and alignment stage.
Maxillary incisor torque is assessed on standardized lateral cephalometric radiographs using the bracket-archwire angle. A tangent is drawn along the base of the maxillary central incisor bracket, and another tangent is drawn parallel to and superimposed on the working archwire. The obtuse angle formed between the two tangents is measured, and the actual torque value is calculated by subtracting 90° from this angle. The change in torque is determined by comparing the measurements recorded at T0 and T1.
Time 0: completion of leveling and alignment stage which is expected to occur within three months, and Time Final: completion of en-masse retraction stage which occurs within 9 - 10 months following the end of the leveling and alignment stage.

合作者和调查者

在这里您可以找到参与这项研究的人员和组织。

调查人员

  • 首席研究员:Abdulmalek M. H. Almasri, DDS、Damascus University

出版物和有用的链接

负责输入研究信息的人员自愿提供这些出版物。这些可能与研究有关。

研究记录日期

这些日期跟踪向 ClinicalTrials.gov 提交研究记录和摘要结果的进度。研究记录和报告的结果由国家医学图书馆 (NLM) 审查,以确保它们在发布到公共网站之前符合特定的质量控制标准。

研究主要日期

学习开始 (实际的)

2025年7月1日

初级完成 (实际的)

2026年4月27日

研究完成 (实际的)

2026年5月1日

研究注册日期

首次提交

2026年6月13日

首先提交符合 QC 标准的

2026年6月17日

首次发布 (实际的)

2026年6月24日

研究记录更新

最后更新发布 (实际的)

2026年6月24日

上次提交的符合 QC 标准的更新

2026年6月17日

最后验证

2026年6月1日

更多信息

与本研究相关的术语

计划个人参与者数据 (IPD)

计划共享个人参与者数据 (IPD)?

不

药物和器械信息、研究文件

研究美国 FDA 监管的药品

不

研究美国 FDA 监管的设备产品

不

此信息直接从 clinicaltrials.gov 网站检索,没有任何更改。如果您有任何更改、删除或更新研究详细信息的请求,请联系 register@clinicaltrials.gov. clinicaltrials.gov 上实施更改,我们的网站上也会自动更新.

订阅