Deze pagina is automatisch vertaald en de nauwkeurigheid van de vertaling kan niet worden gegarandeerd. Raadpleeg de Engelse versie voor een brontekst.

A Novel Bi-dimensional Archwire for Miniscrew-supported En-masse Retraction

17 juni 2026 bijgewerkt door: Damascus University

Preliminary Clinical Evaluation of a Novel Bi-dimensional Archwire During Miniscrew-Supported En-masse Retraction of the Maxillary Anterior Teeth

This study aims to provide a preliminary clinical evaluation of a novel bi-dimensional archwire used during miniscrew-supported en-masse retraction of the maxillary anterior teeth. Adult patients with Class II Division 1 malocclusion requiring extraction of the maxillary first premolars will be screened at the Department of Orthodontics, Faculty of Dentistry, Damascus University. Eligible participants will receive fixed orthodontic treatment followed by en-masse retraction using a custom-made laser-welded bi-dimensional stainless-steel archwire consisting of a 0.019 × 0.025-inch anterior segment and 0.016 × 0.022-inch posterior segments. Retraction will be supported by orthodontic miniscrews and nickel-titanium closed-coil springs. The main outcome will be the monthly rate of maxillary anterior retraction assessed on three-dimensional digital dental models. A secondary outcome will be the change in maxillary incisor torque assessed on lateral cephalometric radiographs. This pilot study is intended to generate preliminary clinical data regarding the feasibility and performance of this novel archwire design.

Studie Overzicht

Gedetailleerde beschrijving

This study was designed as a prospective single-arm pilot clinical trial to provide an initial clinical evaluation of a novel bi-dimensional archwire specifically developed for miniscrew-supported en-masse retraction of the maxillary anterior teeth. In adult orthodontic patients requiring extraction-based treatment, effective space closure depends not only on anchorage control, but also on the ability of the active retraction system to maintain acceptable control of the maxillary incisors during sliding mechanics. Conventional continuous rectangular stainless-steel archwires provide rigidity, but they may still be associated with frictional resistance, wire deformation, and incomplete torque control during retraction.

The archwire investigated in this study was newly developed as a single continuous stainless-steel assembly composed of a 0.019 × 0.025-inch anterior segment and 0.016 × 0.022-inch posterior segments joined by laser welding. The design was intended to combine greater anterior stiffness, to support better torque control of the maxillary incisors, with reduced posterior friction and binding during sliding mechanics. The intervention was applied under direct skeletal anchorage using self-drilling orthodontic miniscrews inserted bilaterally between the maxillary second premolars and first molars. Retraction was performed using nickel-titanium closed-coil springs delivering approximately 250 g of force per side.

Eligible participants were adult patients with skeletal Class II malocclusion and Class II Division 1 dental malocclusion who required extraction of the maxillary first premolars and en-masse retraction of the maxillary anterior teeth as part of their treatment plan. After leveling and alignment, the novel bi-dimensional archwire was inserted and the retraction phase was initiated. Participants were followed prospectively until completion of the en-masse retraction phase.

The primary outcome of the study was the monthly rate of maxillary anterior en-masse retraction assessed on three-dimensional digital dental models. The secondary outcome was the change in maxillary incisor torque measured on standardized lateral cephalometric radiographs using the bracket-archwire angle. This pilot trial was undertaken to determine whether this newly developed archwire could function as a clinically feasible biomechanical option and to generate preliminary outcome estimates for future randomized controlled trials.

Studietype

Ingrijpend

Inschrijving (Werkelijk)

6

Fase

  • Niet toepasbaar

Contacten en locaties

In dit gedeelte vindt u de contactgegevens van degenen die het onderzoek uitvoeren en informatie over waar dit onderzoek wordt uitgevoerd.

Studie Locaties

      • Damascus, Syrië, DM20AM19
        • Department of Orthodontics, Faculty of Dentistry, University of Damascus

Deelname Criteria

Onderzoekers zoeken naar mensen die aan een bepaalde beschrijving voldoen, de zogenaamde geschiktheidscriteria. Enkele voorbeelden van deze criteria zijn iemands algemene gezondheidstoestand of eerdere behandelingen.

Geschiktheidscriteria

Leeftijden die in aanmerking komen voor studie

  • Volwassen

Accepteert gezonde vrijwilligers

Nee

Beschrijving

Inclusion Criteria:

  • Adults aged 18-28 years with skeletal Class II malocclusion (ANB angle 5°-7°)
  • Class II Division 1 dental malocclusion according to Angle classification
  • An average or vertical facial growth pattern
  • A treatment plan requiring extraction of the maxillary first premolars
  • A need for maxillary anterior en-masse retraction
  • The presence of all permanent maxillary teeth except the third molars

Exclusion Criteria:

  • Patients with previous orthodontic treatment,
  • Craniofacial anomalies, systemic diseases affecting bone metabolism
  • Active periodontal disease
  • Poor oral hygiene
  • Missing maxillary permanent teeth, or were using
  • The use of medications known to influence bone metabolism

Studie plan

Dit gedeelte bevat details van het studieplan, inclusief hoe de studie is opgezet en wat de studie meet.

Hoe is de studie opgezet?

Ontwerpdetails

  • Primair doel: Behandeling
  • Toewijzing: NVT
  • Interventioneel model: Opdracht voor een enkele groep
  • Masker: Geen (open label)

Wapens en interventies

Deelnemersgroep / Arm
Interventie / Behandeling
Experimenteel: Bi-dimensional archwire
Participants will be treated using a novel bi-dimensional stainless-steel archwire during miniscrew-supported en-masse retraction of the maxillary anterior teeth
The retraction procedure is going to be conducted using a bi-dimensional archwire which is a single continuous stainless-steel assembly composed of a 0.019 × 0.025-inch anterior segment and 0.016 × 0.022-inch posterior segments joined by laser welding.

Wat meet het onderzoek?

Primaire uitkomstmaten

Uitkomstmaat
Maatregel Beschrijving
Tijdsspanne
Change in the monthly rate of maxillary anterior en-masse retraction
Tijdsspanne: Time 0: completion of leveling and alignment which happens within three months); Times 1, 2, 3, 4, 5 after one, two, three, four, and five months following the end of the leveling and alignment stage; Time Final: at the end of the retraction stage.
The amount of maxillary anterior retraction is assessed on three-dimensional digital dental models using the distance between the incisal edge of the maxillary central incisors and the medial point of the third palatal rugae as a stable intraoral reference. The monthly retraction rate is calculated in millimeters per month by dividing the amount of anterior retraction by the corresponding duration of the retraction interval.
Time 0: completion of leveling and alignment which happens within three months); Times 1, 2, 3, 4, 5 after one, two, three, four, and five months following the end of the leveling and alignment stage; Time Final: at the end of the retraction stage.

Secundaire uitkomstmaten

Uitkomstmaat
Maatregel Beschrijving
Tijdsspanne
Change in maxillary incisor torque
Tijdsspanne: Time 0: completion of leveling and alignment stage which is expected to occur within three months, and Time Final: completion of en-masse retraction stage which occurs within 9 - 10 months following the end of the leveling and alignment stage.
Maxillary incisor torque is assessed on standardized lateral cephalometric radiographs using the bracket-archwire angle. A tangent is drawn along the base of the maxillary central incisor bracket, and another tangent is drawn parallel to and superimposed on the working archwire. The obtuse angle formed between the two tangents is measured, and the actual torque value is calculated by subtracting 90° from this angle. The change in torque is determined by comparing the measurements recorded at T0 and T1.
Time 0: completion of leveling and alignment stage which is expected to occur within three months, and Time Final: completion of en-masse retraction stage which occurs within 9 - 10 months following the end of the leveling and alignment stage.

Medewerkers en onderzoekers

Hier vindt u mensen en organisaties die betrokken zijn bij dit onderzoek.

Onderzoekers

  • Hoofdonderzoeker: Abdulmalek M. H. Almasri, DDS, Damascus University

Publicaties en nuttige links

De persoon die verantwoordelijk is voor het invoeren van informatie over het onderzoek stelt deze publicaties vrijwillig ter beschikking. Dit kan gaan over alles wat met het onderzoek te maken heeft.

Studie record data

Deze datums volgen de voortgang van het onderzoeksdossier en de samenvatting van de ingediende resultaten bij ClinicalTrials.gov. Studieverslagen en gerapporteerde resultaten worden beoordeeld door de National Library of Medicine (NLM) om er zeker van te zijn dat ze voldoen aan specifieke kwaliteitscontrolenormen voordat ze op de openbare website worden geplaatst.

Bestudeer belangrijke data

Studie start (Werkelijk)

1 juli 2025

Primaire voltooiing (Werkelijk)

27 april 2026

Studie voltooiing (Werkelijk)

1 mei 2026

Studieregistratiedata

Eerst ingediend

13 juni 2026

Eerst ingediend dat voldeed aan de QC-criteria

17 juni 2026

Eerst geplaatst (Werkelijk)

24 juni 2026

Updates van studierecords

Laatste update geplaatst (Werkelijk)

24 juni 2026

Laatste update ingediend die voldeed aan QC-criteria

17 juni 2026

Laatst geverifieerd

1 juni 2026

Meer informatie

Termen gerelateerd aan deze studie

Plan Individuele Deelnemersgegevens (IPD)

Bent u van plan om gegevens van individuele deelnemers (IPD) te delen?

NEE

Informatie over medicijnen en apparaten, studiedocumenten

Bestudeert een door de Amerikaanse FDA gereguleerd geneesmiddel

Nee

Bestudeert een door de Amerikaanse FDA gereguleerd apparaatproduct

Nee

Deze informatie is zonder wijzigingen rechtstreeks van de website clinicaltrials.gov gehaald. Als u verzoeken heeft om uw onderzoeksgegevens te wijzigen, te verwijderen of bij te werken, neem dan contact op met register@clinicaltrials.gov. Zodra er een wijziging wordt doorgevoerd op clinicaltrials.gov, wordt deze ook automatisch bijgewerkt op onze website .

Abonneren