Efficacy of the Use of Real-time Continuous Glucose Monitoring on Glycemic Control in Patients With Type 2 Diabetes and Stage 3 and 4 Chronic Kidney Disease.
- Rationale: Glucose control in patients with kidney disease is challenging, as traditional metrics can be unreliable and there is a high risk of hypoglycemia (low blood sugar). Although RT-CGM has shown benefits in other groups, its efficacy in patients with advanced kidney damage needs to be validated to improve their quality of life and prevent disease progression.
- Main objective: To determine whether the use of RT-CGM is more effective than usual care (capillary blood glucose monitoring with a glucometer) in maintaining patients within an optimal glucose range (70-180 mg/dL) over a three-month period.
- Study population: We plan to include 30 patients over 18 years of age with type 2 diabetes and chronic kidney disease (with a glomerular filtration rate less than 60 ml/min), who use insulin and are not on renal replacement therapy such as dialysis.
Methodology: The study is a randomized clinical trial consisting of two phases:
- Selection period (15 days): Blinded monitoring is performed to obtain baseline data.
- Treatment period (90 days): Patients are divided into two groups: the intervention group, which will use the CGM-RT with alarms configured for high and low levels, and the control group, which will continue with traditional fingerstick monitoring.
- Metrics to be evaluated: In addition to time in range, researchers will analyze episodes of hypoglycemia and hyperglycemia, glycemic variability, glycated hemoglobin (HbA1c) levels, and device accuracy.
- Ethical and logistical considerations: The study complies with international and national regulations, guaranteeing the confidentiality and autonomy of the participants. The project has a 24-month timeline and a detailed budget to cover medical personnel, monitoring sensors (Sinocare i3), and laboratory tests.
研究概览
地位
详细说明
Patients diagnosed with type 2 diabetes mellitus and chronic kidney disease treated at the San Ignacio University Hospital in the outpatient clinic who meet the inclusion criteria will be identified. Once identified, they will be invited to participate in this study and will undergo the informed consent process, which will include, for those who accept, completing and signing the informed consent document (Appendix 1). It is clarified that the only intervention to be evaluated will be real-time continuous glucose monitoring; the patient's therapy will not be modified. The study will comprise a selection period and a treatment period.
4.3.1 Selection Period Potential subjects will sign an informed consent form before undergoing any procedure related to the study. During this phase, blinded continuous glucose monitoring will be performed to obtain baseline metabolic control data for 15 days prior to randomization. During this period, participants will be instructed to measure capillary blood glucose according to standard clinical practice. During this follow-up period, seven daily blood glucose readings will be taken to evaluate the device's accuracy in all patients.
4.3.2 Treatment Period Once the blinded monitoring data has been downloaded, randomization will begin. A simple, computer-generated randomization code will be used, managed centrally by a person who will not be aware of each patient's clinical characteristics. The assignment determined by this mechanism cannot be changed by the treating physicians.
- Intervention group (users of real-time continuous glucose monitoring). Participants in the intervention group will be instructed on the use of real-time continuous glucose monitoring. This training will be provided by nursing staff and will include instruction on device use, alarm management, and recommendations for responding to hypoglycemic episodes reported by the device. Alarms will be configured as follows: High Glucose Alert ≥240 mg/dL and Low Glucose Alert ≤70 mg/dL. Data uploaded to the platform by the device will be reviewed monthly by a physician trained in diabetes management, who will make appropriate adjustments to therapy if participants experience hypoglycemic episodes (<54 mg/dL and <70 mg/dL) or recurrent hyperglycemic episodes (>180 mg/dL), according to basal and prandial insulin titration recommendations. This group will be instructed to confirm readings below 70 mg/dL and above 240 mg/dL with capillary blood glucose monitoring to evaluate the device's accuracy within these ranges.
- Control group: Continuous glucose monitoring will be installed, blinded to measure baseline glycemic control metrics and at the end of the study. Patients assigned to the control group will receive routine nursing education on glucometer use, frequency of capillary blood glucose monitoring, and recommendations for managing hypoglycemic episodes. Capillary glucose data will be reviewed monthly by a physician trained in diabetes management, who will make appropriate adjustments to therapy if subjects experience hypoglycemic events (<54 mg/dL and <70 mg/dL) or recurrent hyperglycemic events (>180 mg/dL), according to basal and prandial insulin titration recommendations.
研究类型
注册 (估计的)
阶段
- 不适用
联系人和位置
学习联系方式
- 姓名:Ana M Gómez - Medina, Endocrinologyst
- 电话号码:2817 +57 601 5946161
- 邮箱:agomez@husi.org.co
研究联系人备份
- 姓名:Diana Cristina Henao, MD
- 电话号码:2817 +57 601 5946161
- 邮箱:dchenao@husi.org.co
学习地点
-
-
Cundinamarca
-
Bogotá、Cundinamarca、哥伦比亚、111021
- Hospital Universitario San Ignacio
-
接触:
- Ana M Gómez Medina, MD
- 电话号码:2817 +57 601 5946161
- 邮箱:agomez@husi.org.co
-
-
参与标准
资格标准
适合学习的年龄
- 成人
- 年长者
接受健康志愿者
描述
4.2.1 Inclusion Criteria
- Age over 18 years
- Chronic kidney disease defined as a glomerular filtration rate (GFR) of less than 60 ml/min/1.73 m², in at least two measurements within the six months prior to inclusion.
- Treatment with basal insulin, basal-bolus regimen, or co-formulation with or without oral antidiabetic agents, with or without a GLP-1 analogue, with stable treatment for the last 3 months.
4.2.2 Exclusion Criteria
- Type 1 diabetes.
- Severe cognitive impairment or dysfunction that prevents device management.
- Chronic kidney disease on renal replacement therapy (peritoneal dialysis or hemodialysis).
- Patients with a history of kidney transplantation.
学习计划
研究是如何设计的?
设计细节
- 主要用途:治疗
- 分配:随机化
- 介入模型:并行分配
- 屏蔽:无(打开标签)
武器和干预
参与者组/臂 |
干预/治疗 |
|---|---|
|
有源比较器:Self-monitoring blood glucose
Control group: Continuous glucose monitoring will be installed, blinded to measure baseline glycemic control metrics and at the end of the study.
Patients assigned to the control group will receive routine nursing education on glucometer use, frequency of capillary blood glucose monitoring, and recommendations for managing hypoglycemic episodes.
Capillary glucose data will be reviewed monthly by a physician trained in diabetes management, who will make appropriate adjustments to therapy if subjects experience hypoglycemic events (<54 mg/dL and <70 mg/dL) or recurrent hyperglycemic events (>180 mg/dL), according to basal and prandial insulin titration recommendations.
|
Control group: Continuous glucose monitoring will be installed, blinded to measure baseline glycemic control metrics and at the end of the study.
Patients assigned to the control group will receive routine nursing education on glucometer use, frequency of capillary blood glucose monitoring, and recommendations for managing hypoglycemic episodes.
Capillary glucose data will be reviewed monthly by a physician trained in diabetes management, who will make appropriate adjustments to therapy if subjects experience hypoglycemic events (<54 mg/dL and <70 mg/dL) or recurrent hyperglycemic events (>180 mg/dL), according to basal and prandial insulin titration recommendations.
|
|
实验性的:RT-CGM
Description: Intervention group (users of real-time continuous glucose monitoring).
Participants in the intervention group will be instructed on the use of real-time continuous glucose monitoring.
This training will be provided by nursing staff and will include instruction on device use, alarm management, and recommendations for responding to hypoglycemic episodes reported by the device.
Alarms will be configured as follows: High Glucose Alert ≥240 mg/dL and Low Glucose Alert ≤70 mg/dL.
Data uploaded to the platform by the device will be reviewed monthly by a physician trained in diabetes management, who will make appropriate adjustments to therapy if participants experience hypoglycemic episodes (<54 mg/dL and <70 mg/dL) or recurrent hyperglycemic episodes (>180 mg/dL), according to basal and prandial insulin titration recommendations.
This group will be instructed to confirm readings below 70 mg/dL and above 240 mg/dL with capillary blood glucose monitoring to evaluate the device's
|
Intervention group (users of real-time continuous glucose monitoring).
Participants in the intervention group will be instructed on the use of real-time continuous glucose monitoring.
This training will be provided by nursing staff and will include instruction on device use, alarm management, and recommendations for responding to hypoglycemic episodes reported by the device.
Alarms will be configured as follows: High Glucose Alert ≥240 mg/dL and Low Glucose Alert ≤70 mg/dL.
Data uploaded to the platform by the device will be reviewed monthly by a physician trained in diabetes management, who will make appropriate adjustments to therapy if participants experience hypoglycemic episodes (<54 mg/dL and <70 mg/dL) or recurrent hyperglycemic episodes (>180 mg/dL), according to basal and prandial insulin titration recommendations.
This group will be instructed to confirm readings below 70 mg/dL and above 240 mg/dL with capillary blood glucose monitoring to evaluate the device's accuracy withi
|
研究衡量的是什么?
主要结果指标
结果测量 |
措施说明 |
大体时间 |
|---|---|---|
|
Time in range (TIR)
大体时间:12 weeks
|
Percentage of time in which glucose levels are maintained between 70 - 180 mg/dl.
|
12 weeks
|
次要结果测量
结果测量 |
措施说明 |
大体时间 |
|---|---|---|
|
Time below range (TBR)
大体时间:12 weeks
|
Percentage of time in which glucose levels are maintained below 54 mg/dl and 70 mg/dl
|
12 weeks
|
|
Time above range (TAR)
大体时间:12 weeks
|
Percentage of time in which glucose levels are maintained above 180 mg/dl and 250 mg/dl
|
12 weeks
|
|
Glycemic Variability
大体时间:12 weeks
|
Percentage coefficient of variation
|
12 weeks
|
|
Time in Tight Range (TITR)
大体时间:12 weeks
|
Percentage of time that glucose is between 70-140 mg/dL.
|
12 weeks
|
|
HbA1c
大体时间:12 weeks
|
Glycated hemoglobin percentage
|
12 weeks
|
其他结果措施
结果测量 |
措施说明 |
大体时间 |
|---|---|---|
|
MARD (Mean Absolute Relative Difference)
大体时间:12 weeks
|
The difference between the measurement of the device and the reference measurement, expressed as a percentage of the mean.
|
12 weeks
|
合作者和调查者
研究记录日期
研究主要日期
学习开始 (估计的)
初级完成 (估计的)
研究完成 (估计的)
研究注册日期
首次提交
首先提交符合 QC 标准的
首次发布 (实际的)
研究记录更新
最后更新发布 (实际的)
上次提交的符合 QC 标准的更新
最后验证
更多信息
与本研究相关的术语
其他相关的 MeSH 术语
其他研究编号
- FM-CIE-0839-24
计划个人参与者数据 (IPD)
计划共享个人参与者数据 (IPD)?
IPD 计划说明
药物和器械信息、研究文件
研究美国 FDA 监管的药品
研究美国 FDA 监管的设备产品
此信息直接从 clinicaltrials.gov 网站检索,没有任何更改。如果您有任何更改、删除或更新研究详细信息的请求,请联系 register@clinicaltrials.gov. clinicaltrials.gov 上实施更改,我们的网站上也会自动更新.