Deze pagina is automatisch vertaald en de nauwkeurigheid van de vertaling kan niet worden gegarandeerd. Raadpleeg de Engelse versie voor een brontekst.

Efficacy of the Use of Real-time Continuous Glucose Monitoring on Glycemic Control in Patients With Type 2 Diabetes and Stage 3 and 4 Chronic Kidney Disease.

19 juni 2026 bijgewerkt door: Hospital Universitario San Ignacio
  • Rationale: Glucose control in patients with kidney disease is challenging, as traditional metrics can be unreliable and there is a high risk of hypoglycemia (low blood sugar). Although RT-CGM has shown benefits in other groups, its efficacy in patients with advanced kidney damage needs to be validated to improve their quality of life and prevent disease progression.
  • Main objective: To determine whether the use of RT-CGM is more effective than usual care (capillary blood glucose monitoring with a glucometer) in maintaining patients within an optimal glucose range (70-180 mg/dL) over a three-month period.
  • Study population: We plan to include 30 patients over 18 years of age with type 2 diabetes and chronic kidney disease (with a glomerular filtration rate less than 60 ml/min), who use insulin and are not on renal replacement therapy such as dialysis.
  • Methodology: The study is a randomized clinical trial consisting of two phases:

    1. Selection period (15 days): Blinded monitoring is performed to obtain baseline data.
    2. Treatment period (90 days): Patients are divided into two groups: the intervention group, which will use the CGM-RT with alarms configured for high and low levels, and the control group, which will continue with traditional fingerstick monitoring.
  • Metrics to be evaluated: In addition to time in range, researchers will analyze episodes of hypoglycemia and hyperglycemia, glycemic variability, glycated hemoglobin (HbA1c) levels, and device accuracy.
  • Ethical and logistical considerations: The study complies with international and national regulations, guaranteeing the confidentiality and autonomy of the participants. The project has a 24-month timeline and a detailed budget to cover medical personnel, monitoring sensors (Sinocare i3), and laboratory tests.

Studie Overzicht

Gedetailleerde beschrijving

Patients diagnosed with type 2 diabetes mellitus and chronic kidney disease treated at the San Ignacio University Hospital in the outpatient clinic who meet the inclusion criteria will be identified. Once identified, they will be invited to participate in this study and will undergo the informed consent process, which will include, for those who accept, completing and signing the informed consent document (Appendix 1). It is clarified that the only intervention to be evaluated will be real-time continuous glucose monitoring; the patient's therapy will not be modified. The study will comprise a selection period and a treatment period.

4.3.1 Selection Period Potential subjects will sign an informed consent form before undergoing any procedure related to the study. During this phase, blinded continuous glucose monitoring will be performed to obtain baseline metabolic control data for 15 days prior to randomization. During this period, participants will be instructed to measure capillary blood glucose according to standard clinical practice. During this follow-up period, seven daily blood glucose readings will be taken to evaluate the device's accuracy in all patients.

4.3.2 Treatment Period Once the blinded monitoring data has been downloaded, randomization will begin. A simple, computer-generated randomization code will be used, managed centrally by a person who will not be aware of each patient's clinical characteristics. The assignment determined by this mechanism cannot be changed by the treating physicians.

  • Intervention group (users of real-time continuous glucose monitoring). Participants in the intervention group will be instructed on the use of real-time continuous glucose monitoring. This training will be provided by nursing staff and will include instruction on device use, alarm management, and recommendations for responding to hypoglycemic episodes reported by the device. Alarms will be configured as follows: High Glucose Alert ≥240 mg/dL and Low Glucose Alert ≤70 mg/dL. Data uploaded to the platform by the device will be reviewed monthly by a physician trained in diabetes management, who will make appropriate adjustments to therapy if participants experience hypoglycemic episodes (<54 mg/dL and <70 mg/dL) or recurrent hyperglycemic episodes (>180 mg/dL), according to basal and prandial insulin titration recommendations. This group will be instructed to confirm readings below 70 mg/dL and above 240 mg/dL with capillary blood glucose monitoring to evaluate the device's accuracy within these ranges.
  • Control group: Continuous glucose monitoring will be installed, blinded to measure baseline glycemic control metrics and at the end of the study. Patients assigned to the control group will receive routine nursing education on glucometer use, frequency of capillary blood glucose monitoring, and recommendations for managing hypoglycemic episodes. Capillary glucose data will be reviewed monthly by a physician trained in diabetes management, who will make appropriate adjustments to therapy if subjects experience hypoglycemic events (<54 mg/dL and <70 mg/dL) or recurrent hyperglycemic events (>180 mg/dL), according to basal and prandial insulin titration recommendations.

Studietype

Ingrijpend

Inschrijving (Geschat)

30

Fase

  • Niet toepasbaar

Contacten en locaties

In dit gedeelte vindt u de contactgegevens van degenen die het onderzoek uitvoeren en informatie over waar dit onderzoek wordt uitgevoerd.

Studiecontact

  • Naam: Ana M Gómez - Medina, Endocrinologyst
  • Telefoonnummer: 2817 +57 601 5946161
  • E-mail: agomez@husi.org.co

Studie Contact Back-up

  • Naam: Diana Cristina Henao, MD
  • Telefoonnummer: 2817 +57 601 5946161
  • E-mail: dchenao@husi.org.co

Studie Locaties

    • Cundinamarca
      • Bogotá, Cundinamarca, Colombia, 111021
        • Hospital Universitario San Ignacio
        • Contact:

Deelname Criteria

Onderzoekers zoeken naar mensen die aan een bepaalde beschrijving voldoen, de zogenaamde geschiktheidscriteria. Enkele voorbeelden van deze criteria zijn iemands algemene gezondheidstoestand of eerdere behandelingen.

Geschiktheidscriteria

Leeftijden die in aanmerking komen voor studie

  • Volwassen
  • Oudere volwassene

Accepteert gezonde vrijwilligers

Nee

Beschrijving

4.2.1 Inclusion Criteria

  • Age over 18 years
  • Chronic kidney disease defined as a glomerular filtration rate (GFR) of less than 60 ml/min/1.73 m², in at least two measurements within the six months prior to inclusion.
  • Treatment with basal insulin, basal-bolus regimen, or co-formulation with or without oral antidiabetic agents, with or without a GLP-1 analogue, with stable treatment for the last 3 months.

4.2.2 Exclusion Criteria

  • Type 1 diabetes.
  • Severe cognitive impairment or dysfunction that prevents device management.
  • Chronic kidney disease on renal replacement therapy (peritoneal dialysis or hemodialysis).
  • Patients with a history of kidney transplantation.

Studie plan

Dit gedeelte bevat details van het studieplan, inclusief hoe de studie is opgezet en wat de studie meet.

Hoe is de studie opgezet?

Ontwerpdetails

  • Primair doel: Behandeling
  • Toewijzing: Gerandomiseerd
  • Interventioneel model: Parallelle opdracht
  • Masker: Geen (open label)

Wapens en interventies

Deelnemersgroep / Arm
Interventie / Behandeling
Actieve vergelijker: Self-monitoring blood glucose
Control group: Continuous glucose monitoring will be installed, blinded to measure baseline glycemic control metrics and at the end of the study. Patients assigned to the control group will receive routine nursing education on glucometer use, frequency of capillary blood glucose monitoring, and recommendations for managing hypoglycemic episodes. Capillary glucose data will be reviewed monthly by a physician trained in diabetes management, who will make appropriate adjustments to therapy if subjects experience hypoglycemic events (<54 mg/dL and <70 mg/dL) or recurrent hyperglycemic events (>180 mg/dL), according to basal and prandial insulin titration recommendations.
Control group: Continuous glucose monitoring will be installed, blinded to measure baseline glycemic control metrics and at the end of the study. Patients assigned to the control group will receive routine nursing education on glucometer use, frequency of capillary blood glucose monitoring, and recommendations for managing hypoglycemic episodes. Capillary glucose data will be reviewed monthly by a physician trained in diabetes management, who will make appropriate adjustments to therapy if subjects experience hypoglycemic events (<54 mg/dL and <70 mg/dL) or recurrent hyperglycemic events (>180 mg/dL), according to basal and prandial insulin titration recommendations.
Experimenteel: RT-CGM
Description: Intervention group (users of real-time continuous glucose monitoring). Participants in the intervention group will be instructed on the use of real-time continuous glucose monitoring. This training will be provided by nursing staff and will include instruction on device use, alarm management, and recommendations for responding to hypoglycemic episodes reported by the device. Alarms will be configured as follows: High Glucose Alert ≥240 mg/dL and Low Glucose Alert ≤70 mg/dL. Data uploaded to the platform by the device will be reviewed monthly by a physician trained in diabetes management, who will make appropriate adjustments to therapy if participants experience hypoglycemic episodes (<54 mg/dL and <70 mg/dL) or recurrent hyperglycemic episodes (>180 mg/dL), according to basal and prandial insulin titration recommendations. This group will be instructed to confirm readings below 70 mg/dL and above 240 mg/dL with capillary blood glucose monitoring to evaluate the device's
Intervention group (users of real-time continuous glucose monitoring). Participants in the intervention group will be instructed on the use of real-time continuous glucose monitoring. This training will be provided by nursing staff and will include instruction on device use, alarm management, and recommendations for responding to hypoglycemic episodes reported by the device. Alarms will be configured as follows: High Glucose Alert ≥240 mg/dL and Low Glucose Alert ≤70 mg/dL. Data uploaded to the platform by the device will be reviewed monthly by a physician trained in diabetes management, who will make appropriate adjustments to therapy if participants experience hypoglycemic episodes (<54 mg/dL and <70 mg/dL) or recurrent hyperglycemic episodes (>180 mg/dL), according to basal and prandial insulin titration recommendations. This group will be instructed to confirm readings below 70 mg/dL and above 240 mg/dL with capillary blood glucose monitoring to evaluate the device's accuracy withi

Wat meet het onderzoek?

Primaire uitkomstmaten

Uitkomstmaat
Maatregel Beschrijving
Tijdsspanne
Time in range (TIR)
Tijdsspanne: 12 weeks
Percentage of time in which glucose levels are maintained between 70 - 180 mg/dl.
12 weeks

Secundaire uitkomstmaten

Uitkomstmaat
Maatregel Beschrijving
Tijdsspanne
Time below range (TBR)
Tijdsspanne: 12 weeks
Percentage of time in which glucose levels are maintained below 54 mg/dl and 70 mg/dl
12 weeks
Time above range (TAR)
Tijdsspanne: 12 weeks
Percentage of time in which glucose levels are maintained above 180 mg/dl and 250 mg/dl
12 weeks
Glycemic Variability
Tijdsspanne: 12 weeks
Percentage coefficient of variation
12 weeks
Time in Tight Range (TITR)
Tijdsspanne: 12 weeks
Percentage of time that glucose is between 70-140 mg/dL.
12 weeks
HbA1c
Tijdsspanne: 12 weeks
Glycated hemoglobin percentage
12 weeks

Andere uitkomstmaten

Uitkomstmaat
Maatregel Beschrijving
Tijdsspanne
MARD (Mean Absolute Relative Difference)
Tijdsspanne: 12 weeks
The difference between the measurement of the device and the reference measurement, expressed as a percentage of the mean.
12 weeks

Medewerkers en onderzoekers

Hier vindt u mensen en organisaties die betrokken zijn bij dit onderzoek.

Studie record data

Deze datums volgen de voortgang van het onderzoeksdossier en de samenvatting van de ingediende resultaten bij ClinicalTrials.gov. Studieverslagen en gerapporteerde resultaten worden beoordeeld door de National Library of Medicine (NLM) om er zeker van te zijn dat ze voldoen aan specifieke kwaliteitscontrolenormen voordat ze op de openbare website worden geplaatst.

Bestudeer belangrijke data

Studie start (Geschat)

1 november 2026

Primaire voltooiing (Geschat)

1 februari 2027

Studie voltooiing (Geschat)

30 mei 2027

Studieregistratiedata

Eerst ingediend

28 januari 2026

Eerst ingediend dat voldeed aan de QC-criteria

19 juni 2026

Eerst geplaatst (Werkelijk)

25 juni 2026

Updates van studierecords

Laatste update geplaatst (Werkelijk)

25 juni 2026

Laatste update ingediend die voldeed aan QC-criteria

19 juni 2026

Laatst geverifieerd

1 juni 2026

Meer informatie

Termen gerelateerd aan deze studie

Plan Individuele Deelnemersgegevens (IPD)

Bent u van plan om gegevens van individuele deelnemers (IPD) te delen?

NEE

Beschrijving IPD-plan

The datasets generated and/or analyzed during the current study will not be publicly available because they contain clinical data from patients being monitored at Hospital Universitario San Ignacio.

Informatie over medicijnen en apparaten, studiedocumenten

Bestudeert een door de Amerikaanse FDA gereguleerd geneesmiddel

Nee

Bestudeert een door de Amerikaanse FDA gereguleerd apparaatproduct

Nee

Deze informatie is zonder wijzigingen rechtstreeks van de website clinicaltrials.gov gehaald. Als u verzoeken heeft om uw onderzoeksgegevens te wijzigen, te verwijderen of bij te werken, neem dan contact op met register@clinicaltrials.gov. Zodra er een wijziging wordt doorgevoerd op clinicaltrials.gov, wordt deze ook automatisch bijgewerkt op onze website .

Abonneren