Esta página se tradujo automáticamente y no se garantiza la precisión de la traducción. por favor refiérase a versión inglesa para un texto fuente.

Efficacy of the Use of Real-time Continuous Glucose Monitoring on Glycemic Control in Patients With Type 2 Diabetes and Stage 3 and 4 Chronic Kidney Disease.

19 de junio de 2026 actualizado por: Hospital Universitario San Ignacio
  • Rationale: Glucose control in patients with kidney disease is challenging, as traditional metrics can be unreliable and there is a high risk of hypoglycemia (low blood sugar). Although RT-CGM has shown benefits in other groups, its efficacy in patients with advanced kidney damage needs to be validated to improve their quality of life and prevent disease progression.
  • Main objective: To determine whether the use of RT-CGM is more effective than usual care (capillary blood glucose monitoring with a glucometer) in maintaining patients within an optimal glucose range (70-180 mg/dL) over a three-month period.
  • Study population: We plan to include 30 patients over 18 years of age with type 2 diabetes and chronic kidney disease (with a glomerular filtration rate less than 60 ml/min), who use insulin and are not on renal replacement therapy such as dialysis.
  • Methodology: The study is a randomized clinical trial consisting of two phases:

    1. Selection period (15 days): Blinded monitoring is performed to obtain baseline data.
    2. Treatment period (90 days): Patients are divided into two groups: the intervention group, which will use the CGM-RT with alarms configured for high and low levels, and the control group, which will continue with traditional fingerstick monitoring.
  • Metrics to be evaluated: In addition to time in range, researchers will analyze episodes of hypoglycemia and hyperglycemia, glycemic variability, glycated hemoglobin (HbA1c) levels, and device accuracy.
  • Ethical and logistical considerations: The study complies with international and national regulations, guaranteeing the confidentiality and autonomy of the participants. The project has a 24-month timeline and a detailed budget to cover medical personnel, monitoring sensors (Sinocare i3), and laboratory tests.

Descripción general del estudio

Descripción detallada

Patients diagnosed with type 2 diabetes mellitus and chronic kidney disease treated at the San Ignacio University Hospital in the outpatient clinic who meet the inclusion criteria will be identified. Once identified, they will be invited to participate in this study and will undergo the informed consent process, which will include, for those who accept, completing and signing the informed consent document (Appendix 1). It is clarified that the only intervention to be evaluated will be real-time continuous glucose monitoring; the patient's therapy will not be modified. The study will comprise a selection period and a treatment period.

4.3.1 Selection Period Potential subjects will sign an informed consent form before undergoing any procedure related to the study. During this phase, blinded continuous glucose monitoring will be performed to obtain baseline metabolic control data for 15 days prior to randomization. During this period, participants will be instructed to measure capillary blood glucose according to standard clinical practice. During this follow-up period, seven daily blood glucose readings will be taken to evaluate the device's accuracy in all patients.

4.3.2 Treatment Period Once the blinded monitoring data has been downloaded, randomization will begin. A simple, computer-generated randomization code will be used, managed centrally by a person who will not be aware of each patient's clinical characteristics. The assignment determined by this mechanism cannot be changed by the treating physicians.

  • Intervention group (users of real-time continuous glucose monitoring). Participants in the intervention group will be instructed on the use of real-time continuous glucose monitoring. This training will be provided by nursing staff and will include instruction on device use, alarm management, and recommendations for responding to hypoglycemic episodes reported by the device. Alarms will be configured as follows: High Glucose Alert ≥240 mg/dL and Low Glucose Alert ≤70 mg/dL. Data uploaded to the platform by the device will be reviewed monthly by a physician trained in diabetes management, who will make appropriate adjustments to therapy if participants experience hypoglycemic episodes (<54 mg/dL and <70 mg/dL) or recurrent hyperglycemic episodes (>180 mg/dL), according to basal and prandial insulin titration recommendations. This group will be instructed to confirm readings below 70 mg/dL and above 240 mg/dL with capillary blood glucose monitoring to evaluate the device's accuracy within these ranges.
  • Control group: Continuous glucose monitoring will be installed, blinded to measure baseline glycemic control metrics and at the end of the study. Patients assigned to the control group will receive routine nursing education on glucometer use, frequency of capillary blood glucose monitoring, and recommendations for managing hypoglycemic episodes. Capillary glucose data will be reviewed monthly by a physician trained in diabetes management, who will make appropriate adjustments to therapy if subjects experience hypoglycemic events (<54 mg/dL and <70 mg/dL) or recurrent hyperglycemic events (>180 mg/dL), according to basal and prandial insulin titration recommendations.

Tipo de estudio

Intervencionista

Inscripción (Estimado)

30

Fase

  • No aplica

Contactos y Ubicaciones

Esta sección proporciona los datos de contacto de quienes realizan el estudio e información sobre dónde se lleva a cabo este estudio.

Estudio Contacto

  • Nombre: Ana M Gómez - Medina, Endocrinologyst
  • Número de teléfono: 2817 +57 601 5946161
  • Correo electrónico: agomez@husi.org.co

Copia de seguridad de contactos de estudio

  • Nombre: Diana Cristina Henao, MD
  • Número de teléfono: 2817 +57 601 5946161
  • Correo electrónico: dchenao@husi.org.co

Ubicaciones de estudio

    • Cundinamarca
      • Bogotá, Cundinamarca, Colombia, 111021
        • Hospital Universitario San Ignacio
        • Contacto:
          • Ana M Gómez Medina, MD
          • Número de teléfono: 2817 +57 601 5946161
          • Correo electrónico: agomez@husi.org.co

Criterios de participación

Los investigadores buscan personas que se ajusten a una determinada descripción, denominada criterio de elegibilidad. Algunos ejemplos de estos criterios son el estado de salud general de una persona o tratamientos previos.

Criterio de elegibilidad

Edades elegibles para estudiar

  • Adulto
  • Adulto Mayor

Acepta Voluntarios Saludables

No

Descripción

4.2.1 Inclusion Criteria

  • Age over 18 years
  • Chronic kidney disease defined as a glomerular filtration rate (GFR) of less than 60 ml/min/1.73 m², in at least two measurements within the six months prior to inclusion.
  • Treatment with basal insulin, basal-bolus regimen, or co-formulation with or without oral antidiabetic agents, with or without a GLP-1 analogue, with stable treatment for the last 3 months.

4.2.2 Exclusion Criteria

  • Type 1 diabetes.
  • Severe cognitive impairment or dysfunction that prevents device management.
  • Chronic kidney disease on renal replacement therapy (peritoneal dialysis or hemodialysis).
  • Patients with a history of kidney transplantation.

Plan de estudios

Esta sección proporciona detalles del plan de estudio, incluido cómo está diseñado el estudio y qué mide el estudio.

¿Cómo está diseñado el estudio?

Detalles de diseño

  • Propósito principal: Tratamiento
  • Asignación: Aleatorizado
  • Modelo Intervencionista: Asignación paralela
  • Enmascaramiento: Ninguno (etiqueta abierta)

Armas e Intervenciones

Grupo de participantes/brazo
Intervención / Tratamiento
Comparador activo: Self-monitoring blood glucose
Control group: Continuous glucose monitoring will be installed, blinded to measure baseline glycemic control metrics and at the end of the study. Patients assigned to the control group will receive routine nursing education on glucometer use, frequency of capillary blood glucose monitoring, and recommendations for managing hypoglycemic episodes. Capillary glucose data will be reviewed monthly by a physician trained in diabetes management, who will make appropriate adjustments to therapy if subjects experience hypoglycemic events (<54 mg/dL and <70 mg/dL) or recurrent hyperglycemic events (>180 mg/dL), according to basal and prandial insulin titration recommendations.
Control group: Continuous glucose monitoring will be installed, blinded to measure baseline glycemic control metrics and at the end of the study. Patients assigned to the control group will receive routine nursing education on glucometer use, frequency of capillary blood glucose monitoring, and recommendations for managing hypoglycemic episodes. Capillary glucose data will be reviewed monthly by a physician trained in diabetes management, who will make appropriate adjustments to therapy if subjects experience hypoglycemic events (<54 mg/dL and <70 mg/dL) or recurrent hyperglycemic events (>180 mg/dL), according to basal and prandial insulin titration recommendations.
Experimental: RT-CGM
Description: Intervention group (users of real-time continuous glucose monitoring). Participants in the intervention group will be instructed on the use of real-time continuous glucose monitoring. This training will be provided by nursing staff and will include instruction on device use, alarm management, and recommendations for responding to hypoglycemic episodes reported by the device. Alarms will be configured as follows: High Glucose Alert ≥240 mg/dL and Low Glucose Alert ≤70 mg/dL. Data uploaded to the platform by the device will be reviewed monthly by a physician trained in diabetes management, who will make appropriate adjustments to therapy if participants experience hypoglycemic episodes (<54 mg/dL and <70 mg/dL) or recurrent hyperglycemic episodes (>180 mg/dL), according to basal and prandial insulin titration recommendations. This group will be instructed to confirm readings below 70 mg/dL and above 240 mg/dL with capillary blood glucose monitoring to evaluate the device's
Intervention group (users of real-time continuous glucose monitoring). Participants in the intervention group will be instructed on the use of real-time continuous glucose monitoring. This training will be provided by nursing staff and will include instruction on device use, alarm management, and recommendations for responding to hypoglycemic episodes reported by the device. Alarms will be configured as follows: High Glucose Alert ≥240 mg/dL and Low Glucose Alert ≤70 mg/dL. Data uploaded to the platform by the device will be reviewed monthly by a physician trained in diabetes management, who will make appropriate adjustments to therapy if participants experience hypoglycemic episodes (<54 mg/dL and <70 mg/dL) or recurrent hyperglycemic episodes (>180 mg/dL), according to basal and prandial insulin titration recommendations. This group will be instructed to confirm readings below 70 mg/dL and above 240 mg/dL with capillary blood glucose monitoring to evaluate the device's accuracy withi

¿Qué mide el estudio?

Medidas de resultado primarias

Medida de resultado
Medida Descripción
Periodo de tiempo
Time in range (TIR)
Periodo de tiempo: 12 weeks
Percentage of time in which glucose levels are maintained between 70 - 180 mg/dl.
12 weeks

Medidas de resultado secundarias

Medida de resultado
Medida Descripción
Periodo de tiempo
Time below range (TBR)
Periodo de tiempo: 12 weeks
Percentage of time in which glucose levels are maintained below 54 mg/dl and 70 mg/dl
12 weeks
Time above range (TAR)
Periodo de tiempo: 12 weeks
Percentage of time in which glucose levels are maintained above 180 mg/dl and 250 mg/dl
12 weeks
Glycemic Variability
Periodo de tiempo: 12 weeks
Percentage coefficient of variation
12 weeks
Time in Tight Range (TITR)
Periodo de tiempo: 12 weeks
Percentage of time that glucose is between 70-140 mg/dL.
12 weeks
HbA1c
Periodo de tiempo: 12 weeks
Glycated hemoglobin percentage
12 weeks

Otras medidas de resultado

Medida de resultado
Medida Descripción
Periodo de tiempo
MARD (Mean Absolute Relative Difference)
Periodo de tiempo: 12 weeks
The difference between the measurement of the device and the reference measurement, expressed as a percentage of the mean.
12 weeks

Colaboradores e Investigadores

Aquí es donde encontrará personas y organizaciones involucradas en este estudio.

Fechas de registro del estudio

Estas fechas rastrean el progreso del registro del estudio y los envíos de resultados resumidos a ClinicalTrials.gov. Los registros del estudio y los resultados informados son revisados ​​por la Biblioteca Nacional de Medicina (NLM) para asegurarse de que cumplan con los estándares de control de calidad específicos antes de publicarlos en el sitio web público.

Fechas importantes del estudio

Inicio del estudio (Estimado)

1 de noviembre de 2026

Finalización primaria (Estimado)

1 de febrero de 2027

Finalización del estudio (Estimado)

30 de mayo de 2027

Fechas de registro del estudio

Enviado por primera vez

28 de enero de 2026

Primero enviado que cumplió con los criterios de control de calidad

19 de junio de 2026

Publicado por primera vez (Actual)

25 de junio de 2026

Actualizaciones de registros de estudio

Última actualización publicada (Actual)

25 de junio de 2026

Última actualización enviada que cumplió con los criterios de control de calidad

19 de junio de 2026

Última verificación

1 de junio de 2026

Más información

Términos relacionados con este estudio

Plan de datos de participantes individuales (IPD)

¿Planea compartir datos de participantes individuales (IPD)?

NO

Descripción del plan IPD

The datasets generated and/or analyzed during the current study will not be publicly available because they contain clinical data from patients being monitored at Hospital Universitario San Ignacio.

Información sobre medicamentos y dispositivos, documentos del estudio

Estudia un producto farmacéutico regulado por la FDA de EE. UU.

No

Estudia un producto de dispositivo regulado por la FDA de EE. UU.

No

Esta información se obtuvo directamente del sitio web clinicaltrials.gov sin cambios. Si tiene alguna solicitud para cambiar, eliminar o actualizar los detalles de su estudio, comuníquese con register@clinicaltrials.gov. Tan pronto como se implemente un cambio en clinicaltrials.gov, también se actualizará automáticamente en nuestro sitio web. .

Suscribir