此页面是自动翻译的,不保证翻译的准确性。请参阅 英文版 对于源文本。

Evaluating a New Software (OTOGUIDE) to Help Monitor Electrode Insertion During Cochlear Implant Surgery. (OGUID)

2026年8月19日 更新者:MED-EL Elektromedizinische Geräte GesmbH

Monitoring Electrode Insertion During Cochlear Implant Surgery With OTOGUIDE

Cochlear implants are a successful treatment for severe hearing loss in both children and adults. The procedure involves placing an electrode array into the cochlea to stimulate the auditory nerve, helping patients to hear. For the best results, it's crucial to place the electrode precisely and gently to avoid damaging delicate structures inside the ear. However, currently, surgeons lack feedback on the insertion status, making it difficult to confirm correct electrode positioning, especially regarding insertion depth, such as angle, frequency, or millimeters. New technologies are being developed to provide feedback during surgery, helping surgeons place the electrode more accurately. One such technology, recently developed by MED-EL, is called OTOGUIDE. This software offers immediate information on the electrode's position and functioning during the operation, aiming to improve surgical precision and hearing outcomes.

This clinical investigation aims to evaluate the performance and safety of OTOGUIDE, which assists surgeons during cochlear implant procedures by helping identify the position and angle of electrode contacts placed inside the cochlea. The primary objective is to confirm that OTOGUIDE can accurately detect which electrodes are inserted into the cochlea, with results that are more than 80% consistent with standard CT imaging (either during or after surgery). The secondary objective is to verify that OTOGUIDE can estimate the insertion angle of a specific electrode (C1) with a margin of error smaller than 60 degrees compared to CT imaging.

Participants who agree to take part and sign the informed consent form will undergo up to three study visit, which coincides with their scheduled routine cochlear implant surgery visits. During the Surgery Visit intraoperative measurements will be performed using both OTOGUIDE and the MAESTRO system. CT imaging (either during or after surgery, depending on routine clinical practice) will be used to verify the electrode array's position inside the cochlea.

研究概览

研究类型

介入性

注册 (估计的)

42

阶段

  • 不适用

联系人和位置

本节提供了进行研究的人员的详细联系信息,以及有关进行该研究的地点的信息。

学习联系方式

学习地点

    • Tyrol
      • Innsbruck、Tyrol、奥地利、6020
        • 招聘中
        • Medizinische Universität Innsbruck
        • 接触:
    • Bavaria
      • Munich、Bavaria、德国、81377
        • 尚未招聘
        • Klinikum der Universität München, Campus Großhadern Klinik und Poliklinik für Hals-Nasen-Ohrenheilkunde
        • 接触:

参与标准

研究人员寻找符合特定描述的人,称为资格标准。这些标准的一些例子是一个人的一般健康状况或先前的治疗。

资格标准

适合学习的年龄

  • 成人
  • 年长者

接受健康志愿者

不

描述

Inclusion Criteria:

  • Minimum age of eighteen (18) years at time of enrolment.
  • Subjects to be implanted with a compatible MED-EL cochlear implant (CI) (Mi1200 SYNCHRONY (PIN), Mi1210 SYNCHRONY ST, Mi1250 SYNCHRONY 2 (PIN), Mi1260 SONATA 2) according to clinical routine.
  • Signed and dated informed consent before the start of any study-specific procedure.

Exclusion Criteria:

  • Previously having received a CI on the ear to be tested (Re-implantation).
  • Evidence of ossification or any other cochlear anomaly (e.g., malformation) that might prevent complete insertion of the electrode array or might cause increased risk of infection (e.g. dysplastic cochlear), as confirmed by medical examination and/or as per CT/MRI.
  • Known absence of cochlear development or if the cause of deafness is non-functionality of the auditory nerve and/or the upper auditory pathway.
  • Evidence of active external or middle ear infection or history of recurrent middle ear infection in the ear to be implanted.
  • Acute cholesteatoma
  • The tympanic membrane is perforated in the ear to be implanted.
  • Pre-existing condition known to prohibit CT imaging before and after cochlear implantation.
  • Women being pregnant or nursing.
  • Anything that, in the opinion of the Investigator, would place the subject at increased risk or preclude the subject's full compliance with or completion of the study.

学习计划

本节提供研究计划的详细信息,包括研究的设计方式和研究的衡量标准。

研究是如何设计的?

设计细节

  • 主要用途:诊断
  • 分配:不适用
  • 介入模型:单组作业
  • 屏蔽:无(打开标签)

武器和干预

参与者组/臂
干预/治疗
其他:Monitoring electrode insertion with OTOGUIDE
Monitoring electrode insertion with OTOGUIDE during routine cochlear implantation
OTOGUIDE performs objective measurements to enable the monitoring of the electrode insertion and the functioning of the electrode. OTOGUIDE guides the users through a workflow-based session to assess the implant status and to define a surgical approach. The users can plan an insertion target and monitor the real-time electrode insertion using an impedance-based method to automatically detect the number of contacts inside the cochlea.

研究衡量的是什么?

主要结果指标

结果测量
措施说明
大体时间
Number of inserted electrodes
大体时间:through study completion, an average of 1 year
The primary endpoint is the agreement rate between OTOGUIDE and intra- or post-operative CT imaging in detecting which contacts in an electrode array are inserted and which are not inserted in the cochlea.
through study completion, an average of 1 year

次要结果测量

结果测量
措施说明
大体时间
Insertion angle of C1 electrode contact
大体时间:through study completion, an average of 1 year
The secondary endpoint is the deviation (i.e., the absolute difference) between the insertion angle for the C1 electrode contact estimated by OTOGUIDE and the insertion angle as assessed with intra- or post-operative CT imaging.
through study completion, an average of 1 year

其他结果措施

结果测量
措施说明
大体时间
Deviation in Hz of the frequencies allocated to C1 - C12 electrode contacts
大体时间:through study completion, an average of 1 year
Deviation in Hz of the frequencies allocated to C1 - C12 electrode contacts as estimated by OTOGUIDE and the allocated frequencies as assessed with CT imaging
through study completion, an average of 1 year
Deviation in degree of the insertion angles of C2 - C12 electrode contacts
大体时间:through study completion, an average of 1 year
Deviation in degree of the insertion angles of C2 - C12 electrode contacts estimated by OTOGUIDE and the insertion angles as assessed with intra-or post-operative CT imaging
through study completion, an average of 1 year
Intra-operative impedance values
大体时间:through study completion, an average of 1 year
Deviation in kΩ of the intra-operative impedance values derived from OTOGUIDE and MAESTRO
through study completion, an average of 1 year
Product-specific feedback
大体时间:through study completion, an average of 1 year
OTOGUIDE usability and satisfaction questionnaire for clinicians
through study completion, an average of 1 year

合作者和调查者

在这里您可以找到参与这项研究的人员和组织。

研究记录日期

这些日期跟踪向 ClinicalTrials.gov 提交研究记录和摘要结果的进度。研究记录和报告的结果由国家医学图书馆 (NLM) 审查,以确保它们在发布到公共网站之前符合特定的质量控制标准。

研究主要日期

学习开始 (实际的)

2026年8月18日

初级完成 (估计的)

2027年12月1日

研究完成 (估计的)

2028年2月1日

研究注册日期

首次提交

2026年6月11日

首先提交符合 QC 标准的

2026年7月6日

首次发布 (实际的)

2026年7月8日

研究记录更新

最后更新发布 (实际的)

2026年8月21日

上次提交的符合 QC 标准的更新

2026年8月19日

最后验证

2026年8月1日

更多信息

与本研究相关的术语

其他研究编号

  • MED-EL_CRD_2024_04

计划个人参与者数据 (IPD)

计划共享个人参与者数据 (IPD)?

不

药物和器械信息、研究文件

研究美国 FDA 监管的药品

不

研究美国 FDA 监管的设备产品

不

此信息直接从 clinicaltrials.gov 网站检索,没有任何更改。如果您有任何更改、删除或更新研究详细信息的请求,请联系 register@clinicaltrials.gov. clinicaltrials.gov 上实施更改,我们的网站上也会自动更新.

订阅