AI-Assisted Cholecystectomy Study
AI-Assisted Cholecystectomy With Laparoscopic Surgical Robot: A First-in-Human Study
研究概览
地位
详细说明
Robotic-assisted surgery provides surgeons with enhanced dexterity, stable three-dimensional visualization, and improved ergonomics for minimally invasive procedures. However, despite these technological advances, complex robotic operations remain cognitively demanding and highly coordinated. In addition to controlling the primary operative instruments, surgeons are required to manage auxiliary tasks such as tissue retraction, maintenance of surgical exposure, and coordination of multiple robotic arms. These auxiliary tasks often require frequent switching between control modes, manual adjustments, or verbal coordination with clinical assistants, which may interrupt surgical flow and increase cognitive workload.
In current clinical practice, maintaining stable and optimal exposure of the surgical field is essential for safe dissection and precise manipulation. Elective robotic or laparoscopic cholecystectomy is a standardized and well-established surgical procedure that involves repetitive and well-defined sub-tasks such as tissue retraction, exposure adjustment, and cystic duct and artery clipping. During this procedure, surgeons must repeatedly adjust retraction direction and tension in response to anatomical variation, tissue deformation, and procedural progression. These adjustments are commonly performed by manually controlling an additional robotic arm or by communicating with an assistant surgeon. Such workflows may divert attention from the primary operative task and increase the risk of inefficiency or distraction, particularly during delicate dissection near critical anatomical structures.
To address the challenges associated with auxiliary task management in robotic surgery, we propose a novel voice-assisted automated "third hand" system for supervised surgical assistance. Recent advances in artificial intelligence, robotic perception, and natural language processing have enabled the development of interactive systems capable of understanding spoken commands and executing structured actions in real time. Prior work suggests that voice-based interaction can be feasibly applied in human-machine and human-robot collaboration, indicating its potential as a hands-free control interface [1,2]. At the same time, progress in task-specific robotic control has made it increasingly feasible to deploy limited, well-defined automation under continuous human supervision. Together, these developments create opportunities for designing intelligent assistive systems that support surgical workflow while preserving surgeon authority and responsibility.
The proposed system integrates a natural language interface with task-specific robotic control to enable surgeons to verbally command and adjust a dedicated robotic arm responsible for tissue retraction, exposure maintenance, and selected repetitive actions. Through predefined motion constraints, force limits, and continuous monitoring, the system is designed to function as an assistive tool rather than an autonomous decision-making agent. The surgeon remains fully responsible for procedural planning and execution and may interrupt or override automated actions at any time. The research team has successfully undergone multiple pre-clinical trials including ex-vivo porcine, live porcine as well as cadaveric procedures, confirming the safety of the AI system. (Refer to "Prior Study" section) Elective robotic cholecystectomy provides an appropriate experimental model for evaluating this approach due to its standardized workflow and frequent requirement for dynamic exposure adjustment. By delegating selected auxiliary tasks to an AI-controlled robotic arm while maintaining continuous surgeon supervision, this study enables systematic evaluation of the feasibility, controllability, and safety of limited, task-specific automation. This experiment, therefore, proposes a clinical first-in-human pilot study to evaluate a collaborative surgical framework in which an automated third hand executes constrained sub-tasks under direct surgeon oversight, while voice commands are used to dynamically adjust and coordinate robotic behavior during surgery, without replacing surgeon judgment or decision-making
研究类型
注册 (估计的)
阶段
- 不适用
联系人和位置
学习地点
-
-
-
Hong Kong、香港
- Department of Surgery, Faculty of Medicine, the Chinese University of Hong Kong
-
-
参与标准
资格标准
适合学习的年龄
- 成人
- 年长者
接受健康志愿者
描述
Inclusion Criteria:
- Age >18 years, and
- Body mass index <35kg/m2, and
- Scheduled for elective laparoscopic / robotic cholecystectomy for symptomatic gallstones or gallbladder polyp, and
- American Society of Anesthesiologist (ASA) I-III
Exclusion Criteria:
- Contraindication to general anaesthesia
- Severe concomitant illness that drastically shortens life expectancy or increases risk of therapeutic intervention
- Past history of cholecystitis, liver abscess, Mirizzi syndrome
- Contracted gallbladder or dilated common bile duct on pre-operative imaging
- Known (Child's B or above) liver cirrhosis
- Uncorrectable coagulopathy
- Previous upper abdominal open surgery
- Presence of another malignancy or distant metastasis
- Emergency surgery
- Vulnerable population (e.g. mentally incapacitated or pregnant persons)
学习计划
研究是如何设计的?
设计细节
- 主要用途:治疗
- 分配:不适用
- 介入模型:单组作业
- 屏蔽:无(打开标签)
武器和干预
参与者组/臂 |
干预/治疗 |
|---|---|
|
实验性的:Robotic Assisted Laparoscopic Cholecystectomy Group
The procedure would be performed as per robotic assisted cholecystectomy with 4-port techniques.
After putting under general anaesthesia, a peri-umbilical camera port will be inserted with open technique, followed by introduction of capnoperitoneum at pressure of 12mmHg.
Three additional working ports will be inserted in the upper abdomen under direct laparoscopic vision.
Docking of Sentire surgical robotic system would then be carried out, with subsequent procedure performed by the surgeon at the console.
The Calot's triangle would be dissected first with identification of cystic duct and artery to achieve the critical view of safety.
After ligation of both cystic artery and duct, the gallbladder would be dissected from the liver bed, and retrieved from the peri-umbilical port site in a plastic bag.
The insertion of abdominal drain would be upon discretion of the operating surgeon.
The entire procedure would follow the important surgical principles in preventing bile duct injury or o
|
Robotics Sentire Surgical System is a software-controlled, electromechanical system designed and approved for surgeons to perform MIS in the thorax and abdomen.
The operating surgeon sits at the surgeon console, views the surgical site in a high resolution three-dimensional stereo viewer, and controls movements of the EndoWrist instruments and the camera using two master controllers and a set of foot pedals.
The vision cart includes the supporting electronic and video processing equipment for the system.
The system utilizes one designated robotic manipulator as an assistive arm dedicated to exposure management and auxiliary task support during surgery.
This assistive arm is configured to operate independently from the primary operative instruments and is assigned specifically for tissue retraction, vessel/duct clipping, and maintenance of the surgical field.
Its motion and interaction with tissue are governed by task-specific control algorithms and predefined safety constraints.
|
研究衡量的是什么?
主要结果指标
结果测量 |
措施说明 |
大体时间 |
|---|---|---|
|
Clinical success rate
大体时间:1 day
|
Clinical success refers to completion of the intended cholecystectomy incorporating the AI system without conversion to conventional robot (without AI assistant), laparoscopy, or open surgery, and without intra-operative complication.
|
1 day
|
次要结果测量
结果测量 |
措施说明 |
大体时间 |
|---|---|---|
|
Intraoperative and Postoperative Complications rate
大体时间:30 days
|
Safety data will include all intraoperative and postoperative complications occurring within 30 days following surgery.
Complications will be classified according to standard clinical reporting criteria, including the Clavien-Dindo classification of surgical complications.
|
30 days
|
|
Subjective Assessment of System Performance and Controllability
大体时间:1 day
|
Subjective performance assessment will be conducted using modified task-specific evaluation forms adapted from validated surgical skill assessment tools.
Evaluation will be conducted by the operating surgeon, assisting surgeon, and an independent evaluator, focusing on exposure stability, retraction effectiveness, precision of positioning, and integration with primary surgical workflow.
|
1 day
|
|
Objective Assessment of System Performance and Controllability
大体时间:1 day
|
Objective metrics to be analyzed include:
|
1 day
|
合作者和调查者
研究记录日期
研究主要日期
学习开始 (实际的)
初级完成 (估计的)
研究完成 (估计的)
研究注册日期
首次提交
首先提交符合 QC 标准的
首次发布 (实际的)
研究记录更新
最后更新发布 (实际的)
上次提交的符合 QC 标准的更新
最后验证
更多信息
与本研究相关的术语
其他研究编号
- CRE-2026.237
计划个人参与者数据 (IPD)
计划共享个人参与者数据 (IPD)?
药物和器械信息、研究文件
研究美国 FDA 监管的药品
研究美国 FDA 监管的设备产品
此信息直接从 clinicaltrials.gov 网站检索,没有任何更改。如果您有任何更改、删除或更新研究详细信息的请求,请联系 register@clinicaltrials.gov. clinicaltrials.gov 上实施更改,我们的网站上也会自动更新.