Cette page a été traduite automatiquement et l'exactitude de la traduction n'est pas garantie. Veuillez vous référer au version anglaise pour un texte source.

AI-Assisted Cholecystectomy Study

10 juillet 2026 mis à jour par: Hon Chi Yip, Chinese University of Hong Kong

AI-Assisted Cholecystectomy With Laparoscopic Surgical Robot: A First-in-Human Study

The objective of this prospective clinical pilot study is to evaluate the clinical feasibility, safety, and workflow integration of the voice-based AI-assisted robotic system for performing selected auxiliary tasks during robotic cholecystectomy.

Aperçu de l'étude

Description détaillée

Robotic-assisted surgery provides surgeons with enhanced dexterity, stable three-dimensional visualization, and improved ergonomics for minimally invasive procedures. However, despite these technological advances, complex robotic operations remain cognitively demanding and highly coordinated. In addition to controlling the primary operative instruments, surgeons are required to manage auxiliary tasks such as tissue retraction, maintenance of surgical exposure, and coordination of multiple robotic arms. These auxiliary tasks often require frequent switching between control modes, manual adjustments, or verbal coordination with clinical assistants, which may interrupt surgical flow and increase cognitive workload.

In current clinical practice, maintaining stable and optimal exposure of the surgical field is essential for safe dissection and precise manipulation. Elective robotic or laparoscopic cholecystectomy is a standardized and well-established surgical procedure that involves repetitive and well-defined sub-tasks such as tissue retraction, exposure adjustment, and cystic duct and artery clipping. During this procedure, surgeons must repeatedly adjust retraction direction and tension in response to anatomical variation, tissue deformation, and procedural progression. These adjustments are commonly performed by manually controlling an additional robotic arm or by communicating with an assistant surgeon. Such workflows may divert attention from the primary operative task and increase the risk of inefficiency or distraction, particularly during delicate dissection near critical anatomical structures.

To address the challenges associated with auxiliary task management in robotic surgery, we propose a novel voice-assisted automated "third hand" system for supervised surgical assistance. Recent advances in artificial intelligence, robotic perception, and natural language processing have enabled the development of interactive systems capable of understanding spoken commands and executing structured actions in real time. Prior work suggests that voice-based interaction can be feasibly applied in human-machine and human-robot collaboration, indicating its potential as a hands-free control interface [1,2]. At the same time, progress in task-specific robotic control has made it increasingly feasible to deploy limited, well-defined automation under continuous human supervision. Together, these developments create opportunities for designing intelligent assistive systems that support surgical workflow while preserving surgeon authority and responsibility.

The proposed system integrates a natural language interface with task-specific robotic control to enable surgeons to verbally command and adjust a dedicated robotic arm responsible for tissue retraction, exposure maintenance, and selected repetitive actions. Through predefined motion constraints, force limits, and continuous monitoring, the system is designed to function as an assistive tool rather than an autonomous decision-making agent. The surgeon remains fully responsible for procedural planning and execution and may interrupt or override automated actions at any time. The research team has successfully undergone multiple pre-clinical trials including ex-vivo porcine, live porcine as well as cadaveric procedures, confirming the safety of the AI system. (Refer to "Prior Study" section) Elective robotic cholecystectomy provides an appropriate experimental model for evaluating this approach due to its standardized workflow and frequent requirement for dynamic exposure adjustment. By delegating selected auxiliary tasks to an AI-controlled robotic arm while maintaining continuous surgeon supervision, this study enables systematic evaluation of the feasibility, controllability, and safety of limited, task-specific automation. This experiment, therefore, proposes a clinical first-in-human pilot study to evaluate a collaborative surgical framework in which an automated third hand executes constrained sub-tasks under direct surgeon oversight, while voice commands are used to dynamically adjust and coordinate robotic behavior during surgery, without replacing surgeon judgment or decision-making

Type d'étude

Interventionnel

Inscription (Estimé)

10

Phase

  • N'est pas applicable

Contacts et emplacements

Cette section fournit les coordonnées de ceux qui mènent l'étude et des informations sur le lieu où cette étude est menée.

Lieux d'étude

      • Hong Kong, Hong Kong
        • Department of Surgery, Faculty of Medicine, the Chinese University of Hong Kong

Critères de participation

Les chercheurs recherchent des personnes qui correspondent à une certaine description, appelée critères d'éligibilité. Certains exemples de ces critères sont l'état de santé général d'une personne ou des traitements antérieurs.

Critère d'éligibilité

Âges éligibles pour étudier

  • Adulte
  • Adulte plus âgé

Accepte les volontaires sains

Non

La description

Inclusion Criteria:

  • Age >18 years, and
  • Body mass index <35kg/m2, and
  • Scheduled for elective laparoscopic / robotic cholecystectomy for symptomatic gallstones or gallbladder polyp, and
  • American Society of Anesthesiologist (ASA) I-III

Exclusion Criteria:

  • Contraindication to general anaesthesia
  • Severe concomitant illness that drastically shortens life expectancy or increases risk of therapeutic intervention
  • Past history of cholecystitis, liver abscess, Mirizzi syndrome
  • Contracted gallbladder or dilated common bile duct on pre-operative imaging
  • Known (Child's B or above) liver cirrhosis
  • Uncorrectable coagulopathy
  • Previous upper abdominal open surgery
  • Presence of another malignancy or distant metastasis
  • Emergency surgery
  • Vulnerable population (e.g. mentally incapacitated or pregnant persons)

Plan d'étude

Cette section fournit des détails sur le plan d'étude, y compris la façon dont l'étude est conçue et ce que l'étude mesure.

Comment l'étude est-elle conçue ?

Détails de conception

  • Objectif principal: Traitement
  • Répartition: N / A
  • Modèle interventionnel: Affectation à un seul groupe
  • Masquage: Aucun (étiquette ouverte)

Armes et Interventions

Groupe de participants / Bras
Intervention / Traitement
Expérimental: Robotic Assisted Laparoscopic Cholecystectomy Group
The procedure would be performed as per robotic assisted cholecystectomy with 4-port techniques. After putting under general anaesthesia, a peri-umbilical camera port will be inserted with open technique, followed by introduction of capnoperitoneum at pressure of 12mmHg. Three additional working ports will be inserted in the upper abdomen under direct laparoscopic vision. Docking of Sentire surgical robotic system would then be carried out, with subsequent procedure performed by the surgeon at the console. The Calot's triangle would be dissected first with identification of cystic duct and artery to achieve the critical view of safety. After ligation of both cystic artery and duct, the gallbladder would be dissected from the liver bed, and retrieved from the peri-umbilical port site in a plastic bag. The insertion of abdominal drain would be upon discretion of the operating surgeon. The entire procedure would follow the important surgical principles in preventing bile duct injury or o
Robotics Sentire Surgical System is a software-controlled, electromechanical system designed and approved for surgeons to perform MIS in the thorax and abdomen. The operating surgeon sits at the surgeon console, views the surgical site in a high resolution three-dimensional stereo viewer, and controls movements of the EndoWrist instruments and the camera using two master controllers and a set of foot pedals. The vision cart includes the supporting electronic and video processing equipment for the system. The system utilizes one designated robotic manipulator as an assistive arm dedicated to exposure management and auxiliary task support during surgery. This assistive arm is configured to operate independently from the primary operative instruments and is assigned specifically for tissue retraction, vessel/duct clipping, and maintenance of the surgical field. Its motion and interaction with tissue are governed by task-specific control algorithms and predefined safety constraints.

Que mesure l'étude ?

Principaux critères de jugement

Mesure des résultats
Description de la mesure
Délai
Clinical success rate
Délai: 1 day
Clinical success refers to completion of the intended cholecystectomy incorporating the AI system without conversion to conventional robot (without AI assistant), laparoscopy, or open surgery, and without intra-operative complication.
1 day

Mesures de résultats secondaires

Mesure des résultats
Description de la mesure
Délai
Intraoperative and Postoperative Complications rate
Délai: 30 days
Safety data will include all intraoperative and postoperative complications occurring within 30 days following surgery. Complications will be classified according to standard clinical reporting criteria, including the Clavien-Dindo classification of surgical complications.
30 days
Subjective Assessment of System Performance and Controllability
Délai: 1 day
Subjective performance assessment will be conducted using modified task-specific evaluation forms adapted from validated surgical skill assessment tools. Evaluation will be conducted by the operating surgeon, assisting surgeon, and an independent evaluator, focusing on exposure stability, retraction effectiveness, precision of positioning, and integration with primary surgical workflow.
1 day
Objective Assessment of System Performance and Controllability
Délai: 1 day

Objective metrics to be analyzed include:

  1. Number of retraction adjustments required to maintain adequate exposure during dissection.
  2. Number of activation failures for the voice command.
  3. Number of uses of the emergency stop mechanism during the AI automation.
1 day

Collaborateurs et enquêteurs

C'est ici que vous trouverez les personnes et les organisations impliquées dans cette étude.

Dates d'enregistrement des études

Ces dates suivent la progression des dossiers d'étude et des soumissions de résultats sommaires à ClinicalTrials.gov. Les dossiers d'étude et les résultats rapportés sont examinés par la Bibliothèque nationale de médecine (NLM) pour s'assurer qu'ils répondent à des normes de contrôle de qualité spécifiques avant d'être publiés sur le site Web public.

Dates principales de l'étude

Début de l'étude (Réel)

1 juin 2026

Achèvement primaire (Estimé)

31 mai 2029

Achèvement de l'étude (Estimé)

30 novembre 2029

Dates d'inscription aux études

Première soumission

10 juillet 2026

Première soumission répondant aux critères de contrôle qualité

10 juillet 2026

Première publication (Réel)

15 juillet 2026

Mises à jour des dossiers d'étude

Dernière mise à jour publiée (Réel)

15 juillet 2026

Dernière mise à jour soumise répondant aux critères de contrôle qualité

10 juillet 2026

Dernière vérification

1 juillet 2026

Plus d'information

Termes liés à cette étude

Autres numéros d'identification d'étude

  • CRE-2026.237

Plan pour les données individuelles des participants (IPD)

Prévoyez-vous de partager les données individuelles des participants (DPI) ?

NON

Informations sur les médicaments et les dispositifs, documents d'étude

Étudie un produit pharmaceutique réglementé par la FDA américaine

Non

Étudie un produit d'appareil réglementé par la FDA américaine

Non

Ces informations ont été extraites directement du site Web clinicaltrials.gov sans aucune modification. Si vous avez des demandes de modification, de suppression ou de mise à jour des détails de votre étude, veuillez contacter register@clinicaltrials.gov. Dès qu'un changement est mis en œuvre sur clinicaltrials.gov, il sera également mis à jour automatiquement sur notre site Web .

S'abonner