- ICH GCP
- Registro de ensayos clínicos de EE. UU.
- Ensayo clínico NCT07705828
AI-Assisted Cholecystectomy Study
AI-Assisted Cholecystectomy With Laparoscopic Surgical Robot: A First-in-Human Study
Descripción general del estudio
Estado
Condiciones
Intervención / Tratamiento
Descripción detallada
Robotic-assisted surgery provides surgeons with enhanced dexterity, stable three-dimensional visualization, and improved ergonomics for minimally invasive procedures. However, despite these technological advances, complex robotic operations remain cognitively demanding and highly coordinated. In addition to controlling the primary operative instruments, surgeons are required to manage auxiliary tasks such as tissue retraction, maintenance of surgical exposure, and coordination of multiple robotic arms. These auxiliary tasks often require frequent switching between control modes, manual adjustments, or verbal coordination with clinical assistants, which may interrupt surgical flow and increase cognitive workload.
In current clinical practice, maintaining stable and optimal exposure of the surgical field is essential for safe dissection and precise manipulation. Elective robotic or laparoscopic cholecystectomy is a standardized and well-established surgical procedure that involves repetitive and well-defined sub-tasks such as tissue retraction, exposure adjustment, and cystic duct and artery clipping. During this procedure, surgeons must repeatedly adjust retraction direction and tension in response to anatomical variation, tissue deformation, and procedural progression. These adjustments are commonly performed by manually controlling an additional robotic arm or by communicating with an assistant surgeon. Such workflows may divert attention from the primary operative task and increase the risk of inefficiency or distraction, particularly during delicate dissection near critical anatomical structures.
To address the challenges associated with auxiliary task management in robotic surgery, we propose a novel voice-assisted automated "third hand" system for supervised surgical assistance. Recent advances in artificial intelligence, robotic perception, and natural language processing have enabled the development of interactive systems capable of understanding spoken commands and executing structured actions in real time. Prior work suggests that voice-based interaction can be feasibly applied in human-machine and human-robot collaboration, indicating its potential as a hands-free control interface [1,2]. At the same time, progress in task-specific robotic control has made it increasingly feasible to deploy limited, well-defined automation under continuous human supervision. Together, these developments create opportunities for designing intelligent assistive systems that support surgical workflow while preserving surgeon authority and responsibility.
The proposed system integrates a natural language interface with task-specific robotic control to enable surgeons to verbally command and adjust a dedicated robotic arm responsible for tissue retraction, exposure maintenance, and selected repetitive actions. Through predefined motion constraints, force limits, and continuous monitoring, the system is designed to function as an assistive tool rather than an autonomous decision-making agent. The surgeon remains fully responsible for procedural planning and execution and may interrupt or override automated actions at any time. The research team has successfully undergone multiple pre-clinical trials including ex-vivo porcine, live porcine as well as cadaveric procedures, confirming the safety of the AI system. (Refer to "Prior Study" section) Elective robotic cholecystectomy provides an appropriate experimental model for evaluating this approach due to its standardized workflow and frequent requirement for dynamic exposure adjustment. By delegating selected auxiliary tasks to an AI-controlled robotic arm while maintaining continuous surgeon supervision, this study enables systematic evaluation of the feasibility, controllability, and safety of limited, task-specific automation. This experiment, therefore, proposes a clinical first-in-human pilot study to evaluate a collaborative surgical framework in which an automated third hand executes constrained sub-tasks under direct surgeon oversight, while voice commands are used to dynamically adjust and coordinate robotic behavior during surgery, without replacing surgeon judgment or decision-making
Tipo de estudio
Inscripción (Estimado)
Fase
- No aplica
Contactos y Ubicaciones
Ubicaciones de estudio
-
-
-
Hong Kong, Hong Kong
- Department of Surgery, Faculty of Medicine, the Chinese University of Hong Kong
-
-
Criterios de participación
Criterio de elegibilidad
Edades elegibles para estudiar
- Adulto
- Adulto Mayor
Acepta Voluntarios Saludables
Descripción
Inclusion Criteria:
- Age >18 years, and
- Body mass index <35kg/m2, and
- Scheduled for elective laparoscopic / robotic cholecystectomy for symptomatic gallstones or gallbladder polyp, and
- American Society of Anesthesiologist (ASA) I-III
Exclusion Criteria:
- Contraindication to general anaesthesia
- Severe concomitant illness that drastically shortens life expectancy or increases risk of therapeutic intervention
- Past history of cholecystitis, liver abscess, Mirizzi syndrome
- Contracted gallbladder or dilated common bile duct on pre-operative imaging
- Known (Child's B or above) liver cirrhosis
- Uncorrectable coagulopathy
- Previous upper abdominal open surgery
- Presence of another malignancy or distant metastasis
- Emergency surgery
- Vulnerable population (e.g. mentally incapacitated or pregnant persons)
Plan de estudios
¿Cómo está diseñado el estudio?
Detalles de diseño
- Propósito principal: Tratamiento
- Asignación: N / A
- Modelo Intervencionista: Asignación de un solo grupo
- Enmascaramiento: Ninguno (etiqueta abierta)
Armas e Intervenciones
Grupo de participantes/brazo |
Intervención / Tratamiento |
|---|---|
|
Experimental: Robotic Assisted Laparoscopic Cholecystectomy Group
The procedure would be performed as per robotic assisted cholecystectomy with 4-port techniques.
After putting under general anaesthesia, a peri-umbilical camera port will be inserted with open technique, followed by introduction of capnoperitoneum at pressure of 12mmHg.
Three additional working ports will be inserted in the upper abdomen under direct laparoscopic vision.
Docking of Sentire surgical robotic system would then be carried out, with subsequent procedure performed by the surgeon at the console.
The Calot's triangle would be dissected first with identification of cystic duct and artery to achieve the critical view of safety.
After ligation of both cystic artery and duct, the gallbladder would be dissected from the liver bed, and retrieved from the peri-umbilical port site in a plastic bag.
The insertion of abdominal drain would be upon discretion of the operating surgeon.
The entire procedure would follow the important surgical principles in preventing bile duct injury or o
|
Robotics Sentire Surgical System is a software-controlled, electromechanical system designed and approved for surgeons to perform MIS in the thorax and abdomen.
The operating surgeon sits at the surgeon console, views the surgical site in a high resolution three-dimensional stereo viewer, and controls movements of the EndoWrist instruments and the camera using two master controllers and a set of foot pedals.
The vision cart includes the supporting electronic and video processing equipment for the system.
The system utilizes one designated robotic manipulator as an assistive arm dedicated to exposure management and auxiliary task support during surgery.
This assistive arm is configured to operate independently from the primary operative instruments and is assigned specifically for tissue retraction, vessel/duct clipping, and maintenance of the surgical field.
Its motion and interaction with tissue are governed by task-specific control algorithms and predefined safety constraints.
|
¿Qué mide el estudio?
Medidas de resultado primarias
Medida de resultado |
Medida Descripción |
Periodo de tiempo |
|---|---|---|
|
Clinical success rate
Periodo de tiempo: 1 day
|
Clinical success refers to completion of the intended cholecystectomy incorporating the AI system without conversion to conventional robot (without AI assistant), laparoscopy, or open surgery, and without intra-operative complication.
|
1 day
|
Medidas de resultado secundarias
Medida de resultado |
Medida Descripción |
Periodo de tiempo |
|---|---|---|
|
Intraoperative and Postoperative Complications rate
Periodo de tiempo: 30 days
|
Safety data will include all intraoperative and postoperative complications occurring within 30 days following surgery.
Complications will be classified according to standard clinical reporting criteria, including the Clavien-Dindo classification of surgical complications.
|
30 days
|
|
Subjective Assessment of System Performance and Controllability
Periodo de tiempo: 1 day
|
Subjective performance assessment will be conducted using modified task-specific evaluation forms adapted from validated surgical skill assessment tools.
Evaluation will be conducted by the operating surgeon, assisting surgeon, and an independent evaluator, focusing on exposure stability, retraction effectiveness, precision of positioning, and integration with primary surgical workflow.
|
1 day
|
|
Objective Assessment of System Performance and Controllability
Periodo de tiempo: 1 day
|
Objective metrics to be analyzed include:
|
1 day
|
Colaboradores e Investigadores
Patrocinador
Fechas de registro del estudio
Fechas importantes del estudio
Inicio del estudio (Actual)
Finalización primaria (Estimado)
Finalización del estudio (Estimado)
Fechas de registro del estudio
Enviado por primera vez
Primero enviado que cumplió con los criterios de control de calidad
Publicado por primera vez (Actual)
Actualizaciones de registros de estudio
Última actualización publicada (Actual)
Última actualización enviada que cumplió con los criterios de control de calidad
Última verificación
Más información
Términos relacionados con este estudio
Palabras clave
Otros números de identificación del estudio
- CRE-2026.237
Plan de datos de participantes individuales (IPD)
¿Planea compartir datos de participantes individuales (IPD)?
Información sobre medicamentos y dispositivos, documentos del estudio
Estudia un producto farmacéutico regulado por la FDA de EE. UU.
Estudia un producto de dispositivo regulado por la FDA de EE. UU.
Esta información se obtuvo directamente del sitio web clinicaltrials.gov sin cambios. Si tiene alguna solicitud para cambiar, eliminar o actualizar los detalles de su estudio, comuníquese con register@clinicaltrials.gov. Tan pronto como se implemente un cambio en clinicaltrials.gov, también se actualizará automáticamente en nuestro sitio web. .