此页面是自动翻译的,不保证翻译的准确性。请参阅 英文版 对于源文本。

Computer Guided Immediate Implant Placement in Mandibular Molars Using Patient Specific 3D Printed Polylactic Acid Graft Versus Conventional Immediate Implant Placement With Xenograft (RCT)

2026年8月15日 更新者:Mahmoud Fawzy Mahmoud Mohamed

This randomized controlled clinical trial will evaluate a computer-guided immediate implant placement technique in non-restorable mandibular molars using a patient-specific 3D-printed polylactic acid (PLA) graft and implant position guide, compared with conventional immediate implant placement using xenograft for grafting of the jumping gap.

Eligible patients requiring extraction and immediate implant placement in mandibular molars will be randomly allocated to either the PLA-guided intervention group or the conventional treatment group. In the intervention group, a patient-specific 3D-printed PLA graft and guide will be designed from preoperative CBCT data and used to guide implant placement in the digitally planned position. In the control group, immediate implant placement will be performed using the conventional protocol with xenograft grafting.

The study will assess the primary stability of the dental implant and the accuracy of implant placement compared with the digitally planned position. Implant stability will be measured using the Osstell device, while implant position will be evaluated by superimposing the immediate postoperative CBCT scan on the preoperative CBCT using Blue-Sky Plan software.

Patients will be followed clinically after surgery, with follow-up visits during the healing period and a six-month postoperative CBCT evaluation before implant loading.

研究概览

详细说明

This is a prospective randomized controlled clinical trial designed to evaluate computer-guided immediate implant placement in mandibular molar extraction sockets using a patient-specific 3D-printed polylactic acid (PLA) socket guide and customized root-form PLA graft, compared with conventional freehand immediate implant placement using xenograft.

Immediate implant placement in mandibular molar extraction sockets can be challenging because of the wide socket morphology and the limited amount of bone available for achieving primary implant stability. The interradicular septum and apical bone are important for implant anchorage, while the irregular shape of the extraction socket may make conventional freehand osteotomy preparation and implant positioning difficult.

In the experimental group, preoperative cone-beam computed tomography (CBCT) data will be used for three-dimensional digital planning of the implant position. The implant position, angulation, diameter, and length will be planned using Blue Sky Plan 4 software. A patient-specific socket-supported PLA surgical guide will then be designed according to the planned implant position. A customized root-form PLA graft will also be designed to fit the peri-implant gap within the extraction socket.

The PLA socket guide and customized PLA graft will be fabricated using additive manufacturing. The patient-specific guide will be used during osteotomy preparation to control the drilling trajectory and facilitate placement of the implant according to the digitally planned position. The customized PLA graft will be positioned within the residual gap between the implant and extraction socket walls.

Participants allocated to the control group will undergo conventional immediate implant placement using a freehand surgical technique. Xenograft will be used for grafting of the peri-implant gap according to the conventional treatment protocol.

All participants will undergo preoperative clinical and radiographic assessment. Clinical assessment includes medical and dental history, periodontal assessment, occlusal assessment, and plaque-control assessment. CBCT will be used to evaluate the extraction socket, root morphology, interradicular bone, and available bone dimensions before implant placement.

The primary outcomes of the study are implant primary stability and implant positional accuracy. Implant stability will be assessed using resonance frequency analysis/implant stability measurement at the time of implant placement and during follow-up. Implant positional accuracy will be assessed by comparing the virtually planned implant position with the actual postoperative implant position using CBCT-based evaluation. Positional accuracy will be assessed as a single positional accuracy outcome incorporating the measured deviations between the planned and actual implant position.

Participants will be followed clinically during the healing period, with assessment of implant stability at the planned follow-up period. A postoperative CBCT examination will be used to evaluate the actual implant position and compare it with the preoperative virtual plan.

The study is intended to determine whether the patient-specific 3D-printed PLA socket guide and customized PLA graft can improve primary implant stability and the accuracy of immediate implant placement compared with the conventional freehand technique using xenograft.

研究类型

介入性

注册 (实际的)

17

阶段

  • 不适用

联系人和位置

本节提供了进行研究的人员的详细联系信息,以及有关进行该研究的地点的信息。

学习地点

      • New Cairo、埃及
        • Department of Oral & Maxillofacial Surgery , Faculty of Oral & Dental Medicine , Future University in Egypt

参与标准

研究人员寻找符合特定描述的人,称为资格标准。这些标准的一些例子是一个人的一般健康状况或先前的治疗。

资格标准

适合学习的年龄

  • 成人

接受健康志愿者

不

描述

Inclusion Criteria:

  • Patients requiring immediate implant placement in mandibular molar extraction sockets.
  • Patients with adequate bone volume to accommodate the planned implant.
  • Patients willing to undergo immediate implant placement and follow-up for 6 months.
  • Patients who provided informed consent.

Exclusion Criteria:

  • Uncontrolled systemic diseases or medical conditions contraindicating implant surgery.
  • Patients receiving medications or treatments that may adversely affect bone healing.
  • smokers.
  • Poor oral hygiene or uncontrolled periodontal disease.
  • Acute uncontrolled infection at the surgical site.
  • Conditions requiring additional bone augmentation beyond the study protocol.
  • Patients unable or unwilling to attend the required follow-up visits.

学习计划

本节提供研究计划的详细信息,包括研究的设计方式和研究的衡量标准。

研究是如何设计的?

设计细节

  • 主要用途:治疗
  • 分配:随机化
  • 介入模型:并行分配
  • 屏蔽:无(打开标签)

武器和干预

参与者组/臂
干预/治疗
实验性的:PLA-Guided immediate implant placement
Immediate implant placement using a patient-specific 3D-printed PLA socket guide and customized root-form PLA scaffold
A patient-specific 3D-printed polylactic acid (PLA) socket-supported surgical guide was used to guide implant osteotomy preparation, combined with a customized root-form PLA scaffold designed to occupy the residual peri-implant socket gap and provide structural support during immediate implant placement in mandibular molars.
有源比较器:Conventional Immediate Implant Placement
Freehand immediate implant placement with particulate xenograft to fill the residual peri-implant socket gap
Freehand immediate implant placement with particulate xenograft to fill the residual peri-implant socket gap.

研究衡量的是什么?

主要结果指标

结果测量
措施说明
大体时间
Implant primary stability (IST)
大体时间:Immediately after implant placement
Primary implant stability was measured using resonance frequency analysis and expressed as an Implant Stability Quotient (IST) value.
Immediately after implant placement

次要结果测量

结果测量
措施说明
大体时间
Implant stability at 6 months (IST)
大体时间:6 months after implant placement
Implant stability was assessed using resonance frequency analysis and expressed as an Implant Stability Quotient (IST) value.
6 months after implant placement
Implant positional accuracy
大体时间:Immediately after implant placement
Implant positional accuracy was assessed by comparing the planned and actual implant positions using postoperative CBCT, including coronal, apical, and angular deviations.
Immediately after implant placement

合作者和调查者

在这里您可以找到参与这项研究的人员和组织。

出版物和有用的链接

负责输入研究信息的人员自愿提供这些出版物。这些可能与研究有关。

一般刊物

研究记录日期

这些日期跟踪向 ClinicalTrials.gov 提交研究记录和摘要结果的进度。研究记录和报告的结果由国家医学图书馆 (NLM) 审查,以确保它们在发布到公共网站之前符合特定的质量控制标准。

研究主要日期

学习开始 (实际的)

2024年11月4日

初级完成 (实际的)

2026年5月31日

研究完成 (实际的)

2026年5月31日

研究注册日期

首次提交

2026年8月10日

首先提交符合 QC 标准的

2026年8月15日

首次发布 (实际的)

2026年8月19日

研究记录更新

最后更新发布 (实际的)

2026年8月19日

上次提交的符合 QC 标准的更新

2026年8月15日

最后验证

2026年8月1日

更多信息

与本研究相关的术语

计划个人参与者数据 (IPD)

计划共享个人参与者数据 (IPD)?

不

药物和器械信息、研究文件

研究美国 FDA 监管的药品

不

研究美国 FDA 监管的设备产品

不

在美国制造并从美国出口的产品

不

此信息直接从 clinicaltrials.gov 网站检索,没有任何更改。如果您有任何更改、删除或更新研究详细信息的请求,请联系 register@clinicaltrials.gov. clinicaltrials.gov 上实施更改,我们的网站上也会自动更新.

订阅