Denne side blev automatisk oversat, og nøjagtigheden af ​​oversættelsen er ikke garanteret. Der henvises til engelsk version for en kildetekst.

Computer Guided Immediate Implant Placement in Mandibular Molars Using Patient Specific 3D Printed Polylactic Acid Graft Versus Conventional Immediate Implant Placement With Xenograft (RCT)

15. august 2026 opdateret af: Mahmoud Fawzy Mahmoud Mohamed

This randomized controlled clinical trial will evaluate a computer-guided immediate implant placement technique in non-restorable mandibular molars using a patient-specific 3D-printed polylactic acid (PLA) graft and implant position guide, compared with conventional immediate implant placement using xenograft for grafting of the jumping gap.

Eligible patients requiring extraction and immediate implant placement in mandibular molars will be randomly allocated to either the PLA-guided intervention group or the conventional treatment group. In the intervention group, a patient-specific 3D-printed PLA graft and guide will be designed from preoperative CBCT data and used to guide implant placement in the digitally planned position. In the control group, immediate implant placement will be performed using the conventional protocol with xenograft grafting.

The study will assess the primary stability of the dental implant and the accuracy of implant placement compared with the digitally planned position. Implant stability will be measured using the Osstell device, while implant position will be evaluated by superimposing the immediate postoperative CBCT scan on the preoperative CBCT using Blue-Sky Plan software.

Patients will be followed clinically after surgery, with follow-up visits during the healing period and a six-month postoperative CBCT evaluation before implant loading.

Studieoversigt

Detaljeret beskrivelse

This is a prospective randomized controlled clinical trial designed to evaluate computer-guided immediate implant placement in mandibular molar extraction sockets using a patient-specific 3D-printed polylactic acid (PLA) socket guide and customized root-form PLA graft, compared with conventional freehand immediate implant placement using xenograft.

Immediate implant placement in mandibular molar extraction sockets can be challenging because of the wide socket morphology and the limited amount of bone available for achieving primary implant stability. The interradicular septum and apical bone are important for implant anchorage, while the irregular shape of the extraction socket may make conventional freehand osteotomy preparation and implant positioning difficult.

In the experimental group, preoperative cone-beam computed tomography (CBCT) data will be used for three-dimensional digital planning of the implant position. The implant position, angulation, diameter, and length will be planned using Blue Sky Plan 4 software. A patient-specific socket-supported PLA surgical guide will then be designed according to the planned implant position. A customized root-form PLA graft will also be designed to fit the peri-implant gap within the extraction socket.

The PLA socket guide and customized PLA graft will be fabricated using additive manufacturing. The patient-specific guide will be used during osteotomy preparation to control the drilling trajectory and facilitate placement of the implant according to the digitally planned position. The customized PLA graft will be positioned within the residual gap between the implant and extraction socket walls.

Participants allocated to the control group will undergo conventional immediate implant placement using a freehand surgical technique. Xenograft will be used for grafting of the peri-implant gap according to the conventional treatment protocol.

All participants will undergo preoperative clinical and radiographic assessment. Clinical assessment includes medical and dental history, periodontal assessment, occlusal assessment, and plaque-control assessment. CBCT will be used to evaluate the extraction socket, root morphology, interradicular bone, and available bone dimensions before implant placement.

The primary outcomes of the study are implant primary stability and implant positional accuracy. Implant stability will be assessed using resonance frequency analysis/implant stability measurement at the time of implant placement and during follow-up. Implant positional accuracy will be assessed by comparing the virtually planned implant position with the actual postoperative implant position using CBCT-based evaluation. Positional accuracy will be assessed as a single positional accuracy outcome incorporating the measured deviations between the planned and actual implant position.

Participants will be followed clinically during the healing period, with assessment of implant stability at the planned follow-up period. A postoperative CBCT examination will be used to evaluate the actual implant position and compare it with the preoperative virtual plan.

The study is intended to determine whether the patient-specific 3D-printed PLA socket guide and customized PLA graft can improve primary implant stability and the accuracy of immediate implant placement compared with the conventional freehand technique using xenograft.

Undersøgelsestype

Interventionel

Tilmelding (Faktiske)

17

Fase

  • Ikke anvendelig

Kontakter og lokationer

Dette afsnit indeholder kontaktoplysninger for dem, der udfører undersøgelsen, og oplysninger om, hvor denne undersøgelse udføres.

Studiesteder

      • New Cairo, Egypten
        • Department of Oral & Maxillofacial Surgery , Faculty of Oral & Dental Medicine , Future University in Egypt

Deltagelseskriterier

Forskere leder efter personer, der passer til en bestemt beskrivelse, kaldet berettigelseskriterier. Nogle eksempler på disse kriterier er en persons generelle helbredstilstand eller tidligere behandlinger.

Berettigelseskriterier

Aldre berettiget til at studere

  • Voksen

Tager imod sunde frivillige

Ingen

Beskrivelse

Inclusion Criteria:

  • Patients requiring immediate implant placement in mandibular molar extraction sockets.
  • Patients with adequate bone volume to accommodate the planned implant.
  • Patients willing to undergo immediate implant placement and follow-up for 6 months.
  • Patients who provided informed consent.

Exclusion Criteria:

  • Uncontrolled systemic diseases or medical conditions contraindicating implant surgery.
  • Patients receiving medications or treatments that may adversely affect bone healing.
  • smokers.
  • Poor oral hygiene or uncontrolled periodontal disease.
  • Acute uncontrolled infection at the surgical site.
  • Conditions requiring additional bone augmentation beyond the study protocol.
  • Patients unable or unwilling to attend the required follow-up visits.

Studieplan

Dette afsnit indeholder detaljer om studieplanen, herunder hvordan undersøgelsen er designet, og hvad undersøgelsen måler.

Hvordan er undersøgelsen tilrettelagt?

Design detaljer

  • Primært formål: Behandling
  • Tildeling: Randomiseret
  • Interventionel model: Parallel tildeling
  • Maskning: Ingen (Åben etiket)

Våben og indgreb

Deltagergruppe / Arm
Intervention / Behandling
Eksperimentel: PLA-Guided immediate implant placement
Immediate implant placement using a patient-specific 3D-printed PLA socket guide and customized root-form PLA scaffold
A patient-specific 3D-printed polylactic acid (PLA) socket-supported surgical guide was used to guide implant osteotomy preparation, combined with a customized root-form PLA scaffold designed to occupy the residual peri-implant socket gap and provide structural support during immediate implant placement in mandibular molars.
Aktiv komparator: Conventional Immediate Implant Placement
Freehand immediate implant placement with particulate xenograft to fill the residual peri-implant socket gap
Freehand immediate implant placement with particulate xenograft to fill the residual peri-implant socket gap.

Hvad måler undersøgelsen?

Primære resultatmål

Resultatmål
Foranstaltningsbeskrivelse
Tidsramme
Implant primary stability (IST)
Tidsramme: Immediately after implant placement
Primary implant stability was measured using resonance frequency analysis and expressed as an Implant Stability Quotient (IST) value.
Immediately after implant placement

Sekundære resultatmål

Resultatmål
Foranstaltningsbeskrivelse
Tidsramme
Implant stability at 6 months (IST)
Tidsramme: 6 months after implant placement
Implant stability was assessed using resonance frequency analysis and expressed as an Implant Stability Quotient (IST) value.
6 months after implant placement
Implant positional accuracy
Tidsramme: Immediately after implant placement
Implant positional accuracy was assessed by comparing the planned and actual implant positions using postoperative CBCT, including coronal, apical, and angular deviations.
Immediately after implant placement

Samarbejdspartnere og efterforskere

Det er her, du vil finde personer og organisationer, der er involveret i denne undersøgelse.

Publikationer og nyttige links

Den person, der er ansvarlig for at indtaste oplysninger om undersøgelsen, leverer frivilligt disse publikationer. Disse kan handle om alt relateret til undersøgelsen.

Generelle publikationer

Datoer for undersøgelser

Disse datoer sporer fremskridtene for indsendelser af undersøgelsesrekord og resumeresultater til ClinicalTrials.gov. Studieregistreringer og rapporterede resultater gennemgås af National Library of Medicine (NLM) for at sikre, at de opfylder specifikke kvalitetskontrolstandarder, før de offentliggøres på den offentlige hjemmeside.

Studer store datoer

Studiestart (Faktiske)

4. november 2024

Primær færdiggørelse (Faktiske)

31. maj 2026

Studieafslutning (Faktiske)

31. maj 2026

Datoer for studieregistrering

Først indsendt

10. august 2026

Først indsendt, der opfyldte QC-kriterier

15. august 2026

Først opslået (Faktiske)

19. august 2026

Opdateringer af undersøgelsesjournaler

Sidste opdatering sendt (Faktiske)

19. august 2026

Sidste opdatering indsendt, der opfyldte kvalitetskontrolkriterier

15. august 2026

Sidst verificeret

1. august 2026

Mere information

Begreber relateret til denne undersøgelse

Plan for individuelle deltagerdata (IPD)

Planlægger du at dele individuelle deltagerdata (IPD)?

INGEN

Lægemiddel- og udstyrsoplysninger, undersøgelsesdokumenter

Studerer et amerikansk FDA-reguleret lægemiddelprodukt

Ingen

Studerer et amerikansk FDA-reguleret enhedsprodukt

Ingen

produkt fremstillet i og eksporteret fra U.S.A.

Ingen

Disse oplysninger blev hentet direkte fra webstedet clinicaltrials.gov uden ændringer. Hvis du har nogen anmodninger om at ændre, fjerne eller opdatere dine undersøgelsesoplysninger, bedes du kontakte register@clinicaltrials.gov. Så snart en ændring er implementeret på clinicaltrials.gov, vil denne også blive opdateret automatisk på vores hjemmeside .

Abonner