Computer Guided Immediate Implant Placement in Mandibular Molars Using Patient Specific 3D Printed Polylactic Acid Graft Versus Conventional Immediate Implant Placement With Xenograft (RCT)

August 15, 2026 updated by: Mahmoud Fawzy Mahmoud Mohamed

This randomized controlled clinical trial will evaluate a computer-guided immediate implant placement technique in non-restorable mandibular molars using a patient-specific 3D-printed polylactic acid (PLA) graft and implant position guide, compared with conventional immediate implant placement using xenograft for grafting of the jumping gap.

Eligible patients requiring extraction and immediate implant placement in mandibular molars will be randomly allocated to either the PLA-guided intervention group or the conventional treatment group. In the intervention group, a patient-specific 3D-printed PLA graft and guide will be designed from preoperative CBCT data and used to guide implant placement in the digitally planned position. In the control group, immediate implant placement will be performed using the conventional protocol with xenograft grafting.

The study will assess the primary stability of the dental implant and the accuracy of implant placement compared with the digitally planned position. Implant stability will be measured using the Osstell device, while implant position will be evaluated by superimposing the immediate postoperative CBCT scan on the preoperative CBCT using Blue-Sky Plan software.

Patients will be followed clinically after surgery, with follow-up visits during the healing period and a six-month postoperative CBCT evaluation before implant loading.

Study Overview

Detailed Description

This is a prospective randomized controlled clinical trial designed to evaluate computer-guided immediate implant placement in mandibular molar extraction sockets using a patient-specific 3D-printed polylactic acid (PLA) socket guide and customized root-form PLA graft, compared with conventional freehand immediate implant placement using xenograft.

Immediate implant placement in mandibular molar extraction sockets can be challenging because of the wide socket morphology and the limited amount of bone available for achieving primary implant stability. The interradicular septum and apical bone are important for implant anchorage, while the irregular shape of the extraction socket may make conventional freehand osteotomy preparation and implant positioning difficult.

In the experimental group, preoperative cone-beam computed tomography (CBCT) data will be used for three-dimensional digital planning of the implant position. The implant position, angulation, diameter, and length will be planned using Blue Sky Plan 4 software. A patient-specific socket-supported PLA surgical guide will then be designed according to the planned implant position. A customized root-form PLA graft will also be designed to fit the peri-implant gap within the extraction socket.

The PLA socket guide and customized PLA graft will be fabricated using additive manufacturing. The patient-specific guide will be used during osteotomy preparation to control the drilling trajectory and facilitate placement of the implant according to the digitally planned position. The customized PLA graft will be positioned within the residual gap between the implant and extraction socket walls.

Participants allocated to the control group will undergo conventional immediate implant placement using a freehand surgical technique. Xenograft will be used for grafting of the peri-implant gap according to the conventional treatment protocol.

All participants will undergo preoperative clinical and radiographic assessment. Clinical assessment includes medical and dental history, periodontal assessment, occlusal assessment, and plaque-control assessment. CBCT will be used to evaluate the extraction socket, root morphology, interradicular bone, and available bone dimensions before implant placement.

The primary outcomes of the study are implant primary stability and implant positional accuracy. Implant stability will be assessed using resonance frequency analysis/implant stability measurement at the time of implant placement and during follow-up. Implant positional accuracy will be assessed by comparing the virtually planned implant position with the actual postoperative implant position using CBCT-based evaluation. Positional accuracy will be assessed as a single positional accuracy outcome incorporating the measured deviations between the planned and actual implant position.

Participants will be followed clinically during the healing period, with assessment of implant stability at the planned follow-up period. A postoperative CBCT examination will be used to evaluate the actual implant position and compare it with the preoperative virtual plan.

The study is intended to determine whether the patient-specific 3D-printed PLA socket guide and customized PLA graft can improve primary implant stability and the accuracy of immediate implant placement compared with the conventional freehand technique using xenograft.

Study Type

Interventional

Enrollment (Actual)

17

Phase

  • Not Applicable

Contacts and Locations

This section provides the contact details for those conducting the study, and information on where this study is being conducted.

Study Locations

      • New Cairo, Egypt
        • Department of Oral & Maxillofacial Surgery , Faculty of Oral & Dental Medicine , Future University in Egypt

Participation Criteria

Researchers look for people who fit a certain description, called eligibility criteria. Some examples of these criteria are a person's general health condition or prior treatments.

Eligibility Criteria

Ages Eligible for Study

  • Adult

Accepts Healthy Volunteers

No

Description

Inclusion Criteria:

  • Patients requiring immediate implant placement in mandibular molar extraction sockets.
  • Patients with adequate bone volume to accommodate the planned implant.
  • Patients willing to undergo immediate implant placement and follow-up for 6 months.
  • Patients who provided informed consent.

Exclusion Criteria:

  • Uncontrolled systemic diseases or medical conditions contraindicating implant surgery.
  • Patients receiving medications or treatments that may adversely affect bone healing.
  • smokers.
  • Poor oral hygiene or uncontrolled periodontal disease.
  • Acute uncontrolled infection at the surgical site.
  • Conditions requiring additional bone augmentation beyond the study protocol.
  • Patients unable or unwilling to attend the required follow-up visits.

Study Plan

This section provides details of the study plan, including how the study is designed and what the study is measuring.

How is the study designed?

Design Details

  • Primary Purpose: Treatment
  • Allocation: Randomized
  • Interventional Model: Parallel Assignment
  • Masking: None (Open Label)

Arms and Interventions

Participant Group / Arm
Intervention / Treatment
Experimental: PLA-Guided immediate implant placement
Immediate implant placement using a patient-specific 3D-printed PLA socket guide and customized root-form PLA scaffold
A patient-specific 3D-printed polylactic acid (PLA) socket-supported surgical guide was used to guide implant osteotomy preparation, combined with a customized root-form PLA scaffold designed to occupy the residual peri-implant socket gap and provide structural support during immediate implant placement in mandibular molars.
Active Comparator: Conventional Immediate Implant Placement
Freehand immediate implant placement with particulate xenograft to fill the residual peri-implant socket gap
Freehand immediate implant placement with particulate xenograft to fill the residual peri-implant socket gap.

What is the study measuring?

Primary Outcome Measures

Outcome Measure
Measure Description
Time Frame
Implant primary stability (IST)
Time Frame: Immediately after implant placement
Primary implant stability was measured using resonance frequency analysis and expressed as an Implant Stability Quotient (IST) value.
Immediately after implant placement

Secondary Outcome Measures

Outcome Measure
Measure Description
Time Frame
Implant stability at 6 months (IST)
Time Frame: 6 months after implant placement
Implant stability was assessed using resonance frequency analysis and expressed as an Implant Stability Quotient (IST) value.
6 months after implant placement
Implant positional accuracy
Time Frame: Immediately after implant placement
Implant positional accuracy was assessed by comparing the planned and actual implant positions using postoperative CBCT, including coronal, apical, and angular deviations.
Immediately after implant placement

Collaborators and Investigators

This is where you will find people and organizations involved with this study.

Publications and helpful links

The person responsible for entering information about the study voluntarily provides these publications. These may be about anything related to the study.

General Publications

Study record dates

These dates track the progress of study record and summary results submissions to ClinicalTrials.gov. Study records and reported results are reviewed by the National Library of Medicine (NLM) to make sure they meet specific quality control standards before being posted on the public website.

Study Major Dates

Study Start (Actual)

November 4, 2024

Primary Completion (Actual)

May 31, 2026

Study Completion (Actual)

May 31, 2026

Study Registration Dates

First Submitted

August 10, 2026

First Submitted That Met QC Criteria

August 15, 2026

First Posted (Actual)

August 19, 2026

Study Record Updates

Last Update Posted (Actual)

August 19, 2026

Last Update Submitted That Met QC Criteria

August 15, 2026

Last Verified

August 1, 2026

More Information

Terms related to this study

Plan for Individual participant data (IPD)

Plan to Share Individual Participant Data (IPD)?

NO

Drug and device information, study documents

Studies a U.S. FDA-regulated drug product

No

Studies a U.S. FDA-regulated device product

No

product manufactured in and exported from the U.S.

No

This information was retrieved directly from the website clinicaltrials.gov without any changes. If you have any requests to change, remove or update your study details, please contact register@clinicaltrials.gov. As soon as a change is implemented on clinicaltrials.gov, this will be updated automatically on our website as well.

Subscribe