此页面是自动翻译的,不保证翻译的准确性。请参阅 英文版 对于源文本。

Evaluation of Occlusal Force Following Rapid Maxillary Expansion Assisted by Piezocision in Different Age Groups

2026年9月3日 更新者:Abdulmalek Tawfik Saad、Al-Azhar University

Evaluation of Occlusal Force Following Rapid Maxillary Expansion Assisted by Piezocision in Adolescent Versus Young Adult Orthodontic Patients: A Prospective Clinical Study.

The aim of this prospective clinical study is to evaluate and compare the changes in occlusal force distribution using a quantitative digital occlusal analysis system following piezocision-assisted rapid maxillary expansion (RME) in adolescent versus young adult orthodontic patients. The study hypothesis is that piezocision-assisted RME will result in significant changes in occlusal force distribution and that these outcomes may differ between age groups over a 3-month follow-up period.

研究概览

详细说明

This prospective clinical study evaluates the changes in occlusal force distribution in patients with maxillary transverse deficiency undergoing piezocision-assisted rapid maxillary expansion (RME).

Participants aged 14-22 years with permanent dentition requiring rapid maxillary expansion are allocated into two age-based study groups:

Group I (Adolescents): Patients aged 14-16 years. Group II (Young Adults): Patients aged 18-22 years. All participants undergo piezocision-assisted RME. Under local anesthesia, selective vertical micro-incisions are made interproximally on the buccal alveolar bone distal to the canines, first premolars, and second premolars. Corticotomy cuts to a depth of 3 mm into cortical bone are performed using a piezoelectric surgical device. A bonded tooth-borne Hyrax expander is then cemented and activated two quarters per day (0.5 mm of expansion per day) for 11 days. The expander is maintained as a passive retainer for 3 months to allow stabilization and midpalatal suture remodeling. Primary outcomes evaluate percentage changes in occlusal force distribution at maximum intercuspation across dental arch segments (Anterior vs. Posterior and Right vs. Left), as well as occlusion time and disclusion time during excursive movements, using quantitative digital occlusal force analysis(T-Scan III, Tekscan Inc., Norwood, MA, USA)). Secondary outcomes assess patient-reported pain and discomfort levels at defined time intervals.

研究类型

介入性

注册 (估计的)

16

阶段

  • 不适用

联系人和位置

本节提供了进行研究的人员的详细联系信息,以及有关进行该研究的地点的信息。

学习地点

    • Naser City
      • Cairo、Naser City、埃及、11751
        • Department of Orthodontics, Faculty of Dental Medicine, Al-Azhar University
        • 接触:
        • 接触:
          • Akram Alqadami, Ph.D. Holder
          • 电话号码:+966561010654

参与标准

研究人员寻找符合特定描述的人,称为资格标准。这些标准的一些例子是一个人的一般健康状况或先前的治疗。

资格标准

适合学习的年龄

  • 孩子
  • 成人

接受健康志愿者

不

描述

Inclusion Criteria:

1 - Patients with transverse maxillary deficiency. 2. Age range 14-22 years 3. Permanent dentition stage. 4. Good general and oral health.

Exclusion Criteria:

  1. Craniofacial anomalies or syndromes.
  2. History of orthognathic surgery.
  3. Periodontal disease or significant bone loss.
  4. Systemic diseases affecting bone metabolism.
  5. Previous orthodontic treatment.

学习计划

本节提供研究计划的详细信息,包括研究的设计方式和研究的衡量标准。

研究是如何设计的?

设计细节

  • 主要用途:治疗
  • 分配:随机化
  • 介入模型:并行分配
  • 屏蔽:无(打开标签)

武器和干预

参与者组/臂
干预/治疗
实验性的:Group I: Adolescents
Adolescent patients aged 14-16 years with maxillary transverse deficiency receiving piezocision-assisted rapid maxillary expansion (RME).
Under local anesthesia using Articaine with 1:100,000 Epinephrine, selective vertical micro-incisions are made interproximally through the attached gingiva to the maximum extent possible using a 15c scalpel blade via a flapless technique, extending through the periosteum to reach the alveolar bone. Corticotomy cuts are performed using a piezoelectric surgical device with a BS1 Slim II tip to a depth of 3 mm into cortical bone, initiated 2 mm apical to alveolar crest and safely positioned between adjacent tooth roots to avoid iatrogenic injury. Immediately following surgery, activation of a bonded tooth-borne Hyrax expander commences at a rate of one activation (quarter turn) twice daily (0.5 mm/day) for 11 days, followed by a 3-month passive retention phase for suture remodeling.
其他名称:
  • Piezocision-Assisted RME
  • Piezoelectric Corticotomy
  • Piezo-Assisted Maxillary Expansion
  • Piezocision-Assisted Rapid Palatal Expansion
Quantitative digital measurement of occlusal force parameters using the T-Scan III system (Tekscan, Inc., Norwood, MA, USA) with HD sensors. Static parameters assessed at Maximum Intercuspation (MIC) include: (1) percentage of force distribution between anterior and posterior teeth, and (2) percentage of force symmetry between right and left arch sides. Dynamic parameters assessed include: (1) Occlusion Time (OT) measured from initial tooth contact to MIC, and (2) Disclusion Time (DT) recorded during right, left, and protrusive excursive movements.
其他名称:
  • T-Scan Digital Occlusal System
  • Tekscan Occlusal Force Analysis
  • Digital Occlusal Analysis
  • Digital Occlusal Force Measurement
有源比较器:Group II: Young Adults
Young adult patients aged 18-22 years with maxillary transverse deficiency receiving piezocision-assisted rapid maxillary expansion (RME).
Under local anesthesia using Articaine with 1:100,000 Epinephrine, selective vertical micro-incisions are made interproximally through the attached gingiva to the maximum extent possible using a 15c scalpel blade via a flapless technique, extending through the periosteum to reach the alveolar bone. Corticotomy cuts are performed using a piezoelectric surgical device with a BS1 Slim II tip to a depth of 3 mm into cortical bone, initiated 2 mm apical to alveolar crest and safely positioned between adjacent tooth roots to avoid iatrogenic injury. Immediately following surgery, activation of a bonded tooth-borne Hyrax expander commences at a rate of one activation (quarter turn) twice daily (0.5 mm/day) for 11 days, followed by a 3-month passive retention phase for suture remodeling.
其他名称:
  • Piezocision-Assisted RME
  • Piezoelectric Corticotomy
  • Piezo-Assisted Maxillary Expansion
  • Piezocision-Assisted Rapid Palatal Expansion
Quantitative digital measurement of occlusal force parameters using the T-Scan III system (Tekscan, Inc., Norwood, MA, USA) with HD sensors. Static parameters assessed at Maximum Intercuspation (MIC) include: (1) percentage of force distribution between anterior and posterior teeth, and (2) percentage of force symmetry between right and left arch sides. Dynamic parameters assessed include: (1) Occlusion Time (OT) measured from initial tooth contact to MIC, and (2) Disclusion Time (DT) recorded during right, left, and protrusive excursive movements.
其他名称:
  • T-Scan Digital Occlusal System
  • Tekscan Occlusal Force Analysis
  • Digital Occlusal Analysis
  • Digital Occlusal Force Measurement

研究衡量的是什么?

主要结果指标

结果测量
措施说明
大体时间
Static Occlusal Force Distribution and Symmetry
大体时间:Baseline (T0: Pre-expansion) and 3-month post-expansion (T1).
Percentage of occlusal force distribution between anterior/posterior segments and percentage of force symmetry between right and left sides measured at Maximum Intercuspation (MIC) using T-Scan III.
Baseline (T0: Pre-expansion) and 3-month post-expansion (T1).
Dynamic Occlusal Parameters (Occlusion and Disclusion Times)
大体时间:Baseline (T0: Pre-expansion) and 3-month post-expansion (T1).
Occlusion Time (OT in seconds, measured from initial tooth contact to Maximum Intercuspation [MIC]) and Disclusion Time (DT in seconds, measured from MIC during lateral and protrusive excursive movements until all posterior teeth completely disclude).
Baseline (T0: Pre-expansion) and 3-month post-expansion (T1).

次要结果测量

结果测量
措施说明
大体时间
Postoperative Pain and Discomfort
大体时间:Day 3 (first follow-up), Day 7 (second follow-up), and Day 11 (end of active expansion phase).
Self-reported pain intensity evaluated using a 10-point Visual Analog Scale (VAS), ranging from 0 (no pain) to 10 (worst imaginable pain).
Day 3 (first follow-up), Day 7 (second follow-up), and Day 11 (end of active expansion phase).

合作者和调查者

在这里您可以找到参与这项研究的人员和组织。

研究记录日期

这些日期跟踪向 ClinicalTrials.gov 提交研究记录和摘要结果的进度。研究记录和报告的结果由国家医学图书馆 (NLM) 审查,以确保它们在发布到公共网站之前符合特定的质量控制标准。

研究主要日期

学习开始 (估计的)

2026年10月1日

初级完成 (估计的)

2027年12月1日

研究完成 (估计的)

2028年6月1日

研究注册日期

首次提交

2026年9月3日

首先提交符合 QC 标准的

2026年9月3日

首次发布 (实际的)

2026年9月9日

研究记录更新

最后更新发布 (实际的)

2026年9月9日

上次提交的符合 QC 标准的更新

2026年9月3日

最后验证

2026年9月1日

更多信息

与本研究相关的术语

其他研究编号

  • 1596/588

计划个人参与者数据 (IPD)

计划共享个人参与者数据 (IPD)?

不

IPD 计划说明

Individual participant data will not be made publicly available to protect participant privacy and confidentiality.

药物和器械信息、研究文件

研究美国 FDA 监管的药品

不

研究美国 FDA 监管的设备产品

不

此信息直接从 clinicaltrials.gov 网站检索,没有任何更改。如果您有任何更改、删除或更新研究详细信息的请求,请联系 register@clinicaltrials.gov. clinicaltrials.gov 上实施更改,我们的网站上也会自动更新.

订阅