Early Feasibility Study of 3930M Defibrillation Lead Implantation Via the Middle Cardiac Vein in Patients With Tricuspid Valve Regurgitation (MCV3930 EFS)
Early Feasibility Study of Medtronic OmniaSecure Model 3930M Defibrillation Lead Implantation Via the Middle Cardiac Vein in Patients With Tricuspid Valve Regurgitation: MCV3930 EFS
研究概览
研究类型
注册 (估计的)
阶段
- 不适用
联系人和位置
学习联系方式
- 姓名:Efrah M Hussein, BS
- 电话号码:612-863-0666
- 邮箱:efrah.hussein@allina.com
研究联系人备份
- 姓名:Dawn R Witt, PhD
- 电话号码:612-385-8299
- 邮箱:dawn.witt@allina.com
学习地点
-
-
Minnesota
-
Minneapolis、Minnesota、美国、55407
- Minneapolis Heart Institute Foundation
-
接触:
- Efrah M Hussein, BS
- 电话号码:612-863-0666
- 邮箱:efrah.hussein@allina.com
-
接触:
- Dawn R Witt, PhD
- 电话号码:612-385-8299
- 邮箱:dawn.witt@allina.com
-
首席研究员:
- John S Zakaib, MD
-
-
参与标准
资格标准
适合学习的年龄
- 成人
- 年长者
接受健康志愿者
描述
Inclusion Criteria:
Subject meets current clinical practice guidelines for implantation of ICD or CRT-D and will undergo one of the following:
- Medtronic CRT-D system implant
- Medtronic ICD system implant (single or dual chamber)
- Anatomical suitability for middle cardiac vein lead placement based on pre procedural imaging.
Subject meets both of the following:
- At least Moderate Tricuspid Valve Regurgitation documented by cardiac imaging
- A clinical goal to avoid worsening tricuspid valve regurgitation as determined by the treating physician and/or the patient
- Age 18 years or older.
- Subject is willing to undergo implant defibrillation testing
- Signed Patient Informed Consent Form (ICF).
Exclusion Criteria:
- Life expectancy < 6 months due to non-cardiac comorbidities or advanced frailty where the procedure is not aligned with goals of care
Contraindication to transvenous lead implantation, including:
- Severe or occlusive disease of the axillary/subclavian venous system
- Coronary sinus or middle cardiac vein occlusion, severe stenosis, or anatomy prohibiting safe lead delivery
- Known hypercoagulable state or bleeding disorder is not manageable with standard therapy.
- Subject is contraindicated for ≤1 mg dexamethasone acetate
Patients with a medical condition that precludes them from undergoing defibrillation testing:
- Pre-existing or suspected pneumothorax
- Severe aortic stenosis
- Current Intracardiac LA or LV thrombus
- Severe proximal three-vessel or left main coronary artery disease without revascularization
- Hemodynamic instability
- Unstable angina
- Recent stroke or transient ischemic attack (within the last 6 months)
- Known inadequate external defibrillation
- LVEDD >70 mm
- Any other known medical condition not listed that precludes their participation in the opinion of the Investigator.
- Patient with evidence of active infection or undergoing treatment for an infection.
Inability to provide informed consent, including:
- Cognitive impairment without a legally authorized representative
- Language or communication barriers that prevent adequate understanding of the study
- Unable to follow through study protocol for any reasons (social support, distance from research center, insurance denial, mental illness etc.) in the investigator's judgement
- Pregnant women or breastfeeding women, or women of childbearing potential and who are not on a reliable form of birth regulation method or abstinence
- End-Stage Renal Disease (ESRD) on dialysis
- NYHA IV
- Patient participation in another study that precludes concomitant study participation
学习计划
研究是如何设计的?
设计细节
- 主要用途:设备可行性
- 分配:不适用
- 介入模型:单组作业
- 屏蔽:无(打开标签)
武器和干预
参与者组/臂 |
干预/治疗 |
|---|---|
|
实验性的:Interventional
Patients will undergo implant of the Medtronic 3930M Defibrillation lead via the Middle Cardiac Vein and undergo required electrical testing
|
Required electrical testing for pacing, sensing, impedance, and defibrillation will be completed
|
研究衡量的是什么?
主要结果指标
结果测量 |
措施说明 |
大体时间 |
|---|---|---|
|
Acute Procedural Success
大体时间:Index Procedure
|
Acute Procedural Success, defined as successful implantation of the investigational lead with all the following:
|
Index Procedure
|
次要结果测量
结果测量 |
措施说明 |
大体时间 |
|---|---|---|
|
Lead Electrical Performance and Stability through 90 Days
大体时间:Up to 90 days following implant
|
Evaluation of MCV lead electrical performance and stability through 90 days following implantation, including:
|
Up to 90 days following implant
|
|
Incidence of Device- or Procedure-Related Complications
大体时间:Up to 90 days following implant
|
Number of participants experiencing device- or procedure-related complications through 90 days following implantation: 1. Incidence of device- or procedure-related major adverse events including, but not limited to:
|
Up to 90 days following implant
|
|
Freedom from Device-or Procedure-Related Serious Adverse Events
大体时间:Up to 90 days following implant
|
Proportion of participants free from device-or procedure-related serious adverse events through 90 days following implantation.
|
Up to 90 days following implant
|
其他结果措施
结果测量 |
措施说明 |
大体时间 |
|---|---|---|
|
Tricuspid Valve Parameters
大体时间:6 Month Post Implant
|
Tricuspid Valve Parameters: Tricuspid Valve function, including Tricuspid Valve Regurgitation post implant will be assessed at 6 months post implant or per TTVI protocol
|
6 Month Post Implant
|
合作者和调查者
合作者
调查人员
- 首席研究员:John S Zakaib, MD、Minneapolis Heart Institute Foundation
研究记录日期
研究主要日期
学习开始 (估计的)
初级完成 (估计的)
研究完成 (估计的)
研究注册日期
首次提交
首先提交符合 QC 标准的
首次发布 (实际的)
研究记录更新
最后更新发布 (实际的)
上次提交的符合 QC 标准的更新
最后验证
更多信息
此信息直接从 clinicaltrials.gov 网站检索,没有任何更改。如果您有任何更改、删除或更新研究详细信息的请求,请联系 register@clinicaltrials.gov. clinicaltrials.gov 上实施更改,我们的网站上也会自动更新.