3D Video to Measure Breathing and Breathing-Muscle Activity (KINEVENT)
Non-invasive Measurement of Tidal Volume and Inspiratory Muscle Recruitment Using Three-dimensional Video in Healthy Volunteers Under Incremental Inspiratory Loading: a Pilot Agreement Study
Doctors often need to know how well a patient is breathing. Two things matter: how much air a person moves with each breath, and how hard the breathing muscles are working. Today, measuring these usually requires devices placed on or inside the body, which can be uncomfortable and are not always suitable at the bedside.
This study tests a new way to measure breathing without touching the body. A set of cameras films the surface of the chest and neck and builds a three-dimensional image of how they move during breathing. A computer uses these movements to estimate the amount of air breathed and to detect when the breathing muscles are being used.
The purpose of this study is to check whether the camera-based method is accurate. To do this, the researchers compare it with standard breathing measurements in healthy adult volunteers. During a single session, volunteers breathe normally and then breathe against increasing resistance, which makes breathing a little harder, while the cameras and the standard devices record at the same time.
The study will include 10 healthy volunteers (5 women and 5 men). It does not involve any treatment, and no results are expected to directly benefit the participants. If the method proves accurate, it could later be tested in patients to help monitor breathing in intensive care.
研究概览
地位
条件
研究类型
注册 (估计的)
阶段
- 不适用
联系人和位置
学习联系方式
- 姓名:Guillaume Dumas, MD, PhD
- 电话号码:+33 4 76 76 87 79
- 邮箱:GDumasgalant@chu-grenoble.fr
研究联系人备份
- 姓名:EVA LATCHIMY
- 电话号码:+33 0476767109
- 邮箱:MELatchimy@chu-grenoble.fr
参与标准
资格标准
适合学习的年龄
接受健康志愿者
有资格学习的性别
描述
Inclusion Criteria:
- Adult aged 18 years or older
- No known respiratory, cardiovascular, or neurological disease
- Able to understand and perform the requested breathing maneuvers
- Affiliated with a social security scheme (or beneficiary of one)
- Written informed consent signed
Exclusion Criteria:
- Respiratory, thoracic, or chest wall disease or history
- Body mass index ≥ 30 kg/m²
- Inability to perform the maneuvers (understanding, cooperation)
- Pregnant or breastfeeding woman
- Person deprived of liberty by judicial or administrative decision
- Adult under a legal protection measure
- Person unable to express consent
- Participation in an exclusion period of another study
学习计划
研究是如何设计的?
设计细节
- 主要用途:基础科学
- 分配:不适用
- 介入模型:单组作业
- 屏蔽:无(打开标签)
武器和干预
参与者组/臂 |
干预/治疗 |
|---|---|
|
实验性的:Healthy volunteers - incremental inspiratory loading
Healthy adult volunteers undergo a single measurement session. Breathing is recorded simultaneously by a markerless three-dimensional multi-camera system (surface reconstruction of the torso), a calibrated spirometer (reference tidal volume), and surface electromyography of the sternocleidomastoid and of the diaphragmatic zone of apposition. After a quiet-breathing reference period, participants breathe against stepwise increasing inspiratory resistances, with a Borg dyspnea rating at each step. Video-estimated tidal volume is compared with spirometry (primary outcome: agreement), and video-derived surface deformation indices are compared with surface electromyography. No treatment is given; there is no individual benefit expected. |
A markerless multi-camera system reconstructs the three-dimensional surface of the torso without contact or skin markers. Surface deformations over the respiratory cycle are used to estimate tidal volume and to derive regional indices of respiratory muscle recruitment (cervical region and lower thoraco-abdominal region). During a single session, recordings are acquired simultaneously with a calibrated spirometer (reference tidal volume) and with surface electromyography of the sternocleidomastoid and of the diaphragmatic zone of apposition. The video system is calibrated beforehand on a bench using an artificial lung delivering known volumes. The device is used for measurement only, is non-invasive, and emits no radiation. |
研究衡量的是什么?
主要结果指标
结果测量 |
措施说明 |
大体时间 |
|---|---|---|
|
Agreement between video-estimated and spirometry-measured tidal volume (bias)
大体时间:During the single measurement session (approximately 2 hours)
|
Mean difference (bias, in milliliters) between tidal volume estimated by the three-dimensional video system and tidal volume measured by calibrated spirometry (reference) .The 95% limits of agreement are reported as a supporting measure. |
During the single measurement session (approximately 2 hours)
|
次要结果测量
结果测量 |
措施说明 |
大体时间 |
|---|---|---|
|
Error between video and spirometry volume-time curves
大体时间:During the single measurement session (approximately 2 hours)
|
Normalized root mean square error (nRMSE, dimensionless) between the continuous volume-time curve from the three-dimensional video system and calibrated spirometry (reference). |
During the single measurement session (approximately 2 hours)
|
|
Correlation between cervical-region video signal and sternocleidomastoid surface EMG
大体时间:During the single measurement session (approximately 2 hours)
|
Repeated-measures correlation coefficient (rmcorr, dimensionless, range -1 to 1) between the cervical-region video signal (three-dimensional video system) and the normalized surface electromyography amplitude of the sternocleidomastoid muscle (% of maximal activation). |
During the single measurement session (approximately 2 hours)
|
|
Robustness of video-spirometry agreement and of video volume measurement across inspiratory load levels
大体时间:During the single measurement session (approximately 2 hours)
|
Mean difference (bias, in milliliters) between video-estimated and spirometry-measured tidal volume, reported separately for each inspiratory load level. The 95% limits of agreement are reported as a supporting measure. |
During the single measurement session (approximately 2 hours)
|
合作者和调查者
调查人员
- 研究主任:Guillaume Dumas, MD, PhD、University Grenoble Alps
研究记录日期
研究主要日期
学习开始 (估计的)
初级完成 (估计的)
研究完成 (估计的)
研究注册日期
首次提交
首先提交符合 QC 标准的
首次发布 (实际的)
研究记录更新
最后更新发布 (实际的)
上次提交的符合 QC 标准的更新
最后验证
更多信息
与本研究相关的术语
关键字
其他研究编号
- 38RC26.0329
药物和器械信息、研究文件
研究美国 FDA 监管的药品
研究美国 FDA 监管的设备产品
此信息直接从 clinicaltrials.gov 网站检索,没有任何更改。如果您有任何更改、删除或更新研究详细信息的请求,请联系 register@clinicaltrials.gov. clinicaltrials.gov 上实施更改,我们的网站上也会自动更新.