Questa pagina è stata tradotta automaticamente e l'accuratezza della traduzione non è garantita. Si prega di fare riferimento al Versione inglese per un testo di partenza.

3D Video to Measure Breathing and Breathing-Muscle Activity (KINEVENT)

20 novembre 2026 aggiornato da: EssaiClinique_KINEVENT

Non-invasive Measurement of Tidal Volume and Inspiratory Muscle Recruitment Using Three-dimensional Video in Healthy Volunteers Under Incremental Inspiratory Loading: a Pilot Agreement Study

Doctors often need to know how well a patient is breathing. Two things matter: how much air a person moves with each breath, and how hard the breathing muscles are working. Today, measuring these usually requires devices placed on or inside the body, which can be uncomfortable and are not always suitable at the bedside.

This study tests a new way to measure breathing without touching the body. A set of cameras films the surface of the chest and neck and builds a three-dimensional image of how they move during breathing. A computer uses these movements to estimate the amount of air breathed and to detect when the breathing muscles are being used.

The purpose of this study is to check whether the camera-based method is accurate. To do this, the researchers compare it with standard breathing measurements in healthy adult volunteers. During a single session, volunteers breathe normally and then breathe against increasing resistance, which makes breathing a little harder, while the cameras and the standard devices record at the same time.

The study will include 10 healthy volunteers (5 women and 5 men). It does not involve any treatment, and no results are expected to directly benefit the participants. If the method proves accurate, it could later be tested in patients to help monitor breathing in intensive care.

Panoramica dello studio

Tipo di studio

Interventistico

Iscrizione (Stimato)

10

Fase

  • Non applicabile

Contatti e Sedi

Questa sezione fornisce i recapiti di coloro che conducono lo studio e informazioni su dove viene condotto lo studio.

Contatto studio

Backup dei contatti dello studio

Criteri di partecipazione

I ricercatori cercano persone che corrispondano a una certa descrizione, chiamata criteri di ammissibilità. Alcuni esempi di questi criteri sono le condizioni generali di salute di una persona o trattamenti precedenti.

Criteri di ammissibilità

Età idonea allo studio

18 anni e precedenti (Adulto, Adulto più anziano)

Accetta volontari sani

Sì

Sessi ammissibili allo studio

Tutto

Descrizione

Inclusion Criteria:

  • Adult aged 18 years or older
  • No known respiratory, cardiovascular, or neurological disease
  • Able to understand and perform the requested breathing maneuvers
  • Affiliated with a social security scheme (or beneficiary of one)
  • Written informed consent signed

Exclusion Criteria:

  • Respiratory, thoracic, or chest wall disease or history
  • Body mass index ≥ 30 kg/m²
  • Inability to perform the maneuvers (understanding, cooperation)
  • Pregnant or breastfeeding woman
  • Person deprived of liberty by judicial or administrative decision
  • Adult under a legal protection measure
  • Person unable to express consent
  • Participation in an exclusion period of another study

Piano di studio

Questa sezione fornisce i dettagli del piano di studio, compreso il modo in cui lo studio è progettato e ciò che lo studio sta misurando.

Come è strutturato lo studio?

Dettagli di progettazione

  • Scopo principale: Scienza basilare
  • Assegnazione: N / A
  • Modello interventistico: Assegnazione di gruppo singolo
  • Mascheramento: Nessuno (etichetta aperta)

Armi e interventi

Gruppo di partecipanti / Arm
Intervento / Trattamento
Sperimentale: Healthy volunteers - incremental inspiratory loading

Healthy adult volunteers undergo a single measurement session. Breathing is recorded simultaneously by a markerless three-dimensional multi-camera system (surface reconstruction of the torso), a calibrated spirometer (reference tidal volume), and surface electromyography of the sternocleidomastoid and of the diaphragmatic zone of apposition. After a quiet-breathing reference period, participants breathe against stepwise increasing inspiratory resistances, with a Borg dyspnea rating at each step. Video-estimated tidal volume is compared with spirometry (primary outcome: agreement), and video-derived surface deformation indices are compared with surface electromyography. No treatment is given; there is no individual benefit expected.

A markerless multi-camera system reconstructs the three-dimensional surface of the torso without contact or skin markers. Surface deformations over the respiratory cycle are used to estimate tidal volume and to derive regional indices of respiratory muscle recruitment (cervical region and lower thoraco-abdominal region). During a single session, recordings are acquired simultaneously with a calibrated spirometer (reference tidal volume) and with surface electromyography of the sternocleidomastoid and of the diaphragmatic zone of apposition. The video system is calibrated beforehand on a bench using an artificial lung delivering known volumes. The device is used for measurement only, is non-invasive, and emits no radiation.

Cosa sta misurando lo studio?

Misure di risultato primarie

Misura del risultato
Misura Descrizione
Lasso di tempo
Agreement between video-estimated and spirometry-measured tidal volume (bias)
Lasso di tempo: During the single measurement session (approximately 2 hours)

Mean difference (bias, in milliliters) between tidal volume estimated by the three-dimensional video system and tidal volume measured by calibrated spirometry (reference) .The 95% limits of agreement are reported as a supporting measure.

During the single measurement session (approximately 2 hours)

Misure di risultato secondarie

Misura del risultato
Misura Descrizione
Lasso di tempo
Error between video and spirometry volume-time curves
Lasso di tempo: During the single measurement session (approximately 2 hours)

Normalized root mean square error (nRMSE, dimensionless) between the continuous volume-time curve from the three-dimensional video system and calibrated spirometry (reference).

During the single measurement session (approximately 2 hours)
Correlation between cervical-region video signal and sternocleidomastoid surface EMG
Lasso di tempo: During the single measurement session (approximately 2 hours)

Repeated-measures correlation coefficient (rmcorr, dimensionless, range -1 to 1) between the cervical-region video signal (three-dimensional video system) and the normalized surface electromyography amplitude of the sternocleidomastoid muscle (% of maximal activation).

During the single measurement session (approximately 2 hours)
Robustness of video-spirometry agreement and of video volume measurement across inspiratory load levels
Lasso di tempo: During the single measurement session (approximately 2 hours)

Mean difference (bias, in milliliters) between video-estimated and spirometry-measured tidal volume, reported separately for each inspiratory load level. The 95% limits of agreement are reported as a supporting measure.

During the single measurement session (approximately 2 hours)

Collaboratori e investigatori

Qui è dove troverai le persone e le organizzazioni coinvolte in questo studio.

Investigatori

  • Direttore dello studio: Guillaume Dumas, MD, PhD, University Grenoble Alps

Studiare le date dei record

Queste date tengono traccia dell'avanzamento della registrazione dello studio e dell'invio dei risultati di sintesi a ClinicalTrials.gov. I record degli studi e i risultati riportati vengono esaminati dalla National Library of Medicine (NLM) per assicurarsi che soddisfino specifici standard di controllo della qualità prima di essere pubblicati sul sito Web pubblico.

Studia le date principali

Inizio studio (Stimato)

1 dicembre 2026

Completamento primario (Stimato)

1 giugno 2027

Completamento dello studio (Stimato)

1 dicembre 2027

Date di iscrizione allo studio

Primo inviato

16 novembre 2026

Primo inviato che soddisfa i criteri di controllo qualità

20 novembre 2026

Primo Inserito (Effettivo)

24 novembre 2026

Aggiornamenti dei record di studio

Ultimo aggiornamento pubblicato (Effettivo)

24 novembre 2026

Ultimo aggiornamento inviato che soddisfa i criteri QC

20 novembre 2026

Ultimo verificato

1 novembre 2026

Maggiori informazioni

Termini relativi a questo studio

Informazioni su farmaci e dispositivi, documenti di studio

Studia un prodotto farmaceutico regolamentato dalla FDA degli Stati Uniti

No

Studia un dispositivo regolamentato dalla FDA degli Stati Uniti

No

Queste informazioni sono state recuperate direttamente dal sito web clinicaltrials.gov senza alcuna modifica. In caso di richieste di modifica, rimozione o aggiornamento dei dettagli dello studio, contattare register@clinicaltrials.gov. Non appena verrà implementata una modifica su clinicaltrials.gov, questa verrà aggiornata automaticamente anche sul nostro sito web .

Sottoscrivi